Home > Vidikron > Projector > Vidikron Projector Model 75 User Manual

Vidikron Projector Model 75 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Vidikron Projector Model 75 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 Vidikron manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Operation
    Vidikron Vision Model 65/Model 75 Installation/Operation Manual 55 
    •Pincushion: “Pincushion” distortion can sometimes occur if the throw distance is very 
    short and/or the projector is equipped with an anamorphic lens (refer to 
    Installing and 
    Adjusting the CineWide Anamorphic Lens in Section 3). To correct it, select Pincushion 
    from the GeoCorrection menu and use the  or  button to make the image rectangular. 
    See Figure 4-7. 
    Figure 4-7. Pincushion Correction
    Positive values
    increase image height
    at screen center. Negative values
    decrease image height
    at screen center.
    - +
    Projector Projected Image 
    						
    							Operation
    56 Vidikron Vision Model 65/Model 75 Installation/Operation Manual
    Overscan: Overscan pushes the outside edge of the active picture area of the video signal 
    out beyond the edge of the display area. 
    Some television programs are produced based on the assumption that older television sets 
    may not display the outer edges of the broadcast picture area. 
    Overscan effectively trims 
    away these inactive, outer edges and enlarges the remaining portion of the image to fill the 
    display area.
    Use the on-screen slidebar to select the desired amount of over scan.
    For HDTV, DVDs and other video sources, overscan is generally not necessary or desirable.
    HD & RGB Adjust: Use the settings in the HD & RGB Adjust menu to fine-tune 480p and 
    higher-resolution signals for optimum picture quality. 
    •Auto: Adjusts the phase, frequency and position automatically.
    •Frequency: Adjusts the frequency of the signal.
    •Phase: Adjust the phase if the image (usually from an RGB source) shows shimmer or 
    “noise.” Pixel phase adjusts the phase of the pixel sampling clock relative to the incoming 
    signal. The effect of this control is similar to that of a tracking control on a VCR. 
    For best results, use a good test pattern such as a smooth gray consisting of a clear pattern 
    of black and white pixels, or a similar “half on, half off” graphic image. (You may find that 
    you can stabilize the image at more than one point. Use either setting in this case.) 
    • H. Position: Adjusts the horizontal position of the image. 
    •V. Position: Adjusts the vertical position of the image. 
    OSD Setup: Choose OSD Setup from the Installation menu to change the behavior or 
    appearance of the OSD menus. 
    •OSD Timer: Use the  or  button to set the OSD Timer. This timer controls how long 
    the menus remain on-screen after selecting them. Select from 0 to 60 seconds, in 
    3-second increments. When you set the 
    OSD Timer to 0, the menus remain on-screen until 
    you hide them by pressing MENU. 
    •OSD Position: To adjust the horizontal and vertical position of the OSD, press the  or  
    button to select H. Position or V. Position and use the  or  button to adjust.
    Blue Image: Press the  or  button to turn the Blue Image Off or On. This feature removes 
    all red and green color information from the image (simulating a blue filter), and is useful for 
    color-calibrating the projector or other video components. 
    Sleep Timer: The Sleep Timer automatically puts the projector into standby mode after the 
    amount of time you specify here. (A warning appears on-screen one minute before this is to 
    occur.) 
    Use the  or  button to set the timer for anywhere from 30 minutes to 6 hours, in 
    30-minute increments. To disable the Sleep Timer, set it to 0.  
    						
    							Operation
    Vidikron Vision Model 65/Model 75 Installation/Operation Manual 57 
    InformationSelect Information from the Main Menu to see projector status information: the 
    currently-active source, input signal resolution, aspect ratio, picture memory and lamp 
    usage. This menu also displays the projector serial number.
    Should you ever need to contact Vidikron Technical Support, this information will help them 
    answer your questions or resolve product performance issues. 
    SetupTo access advanced projector settings, use the up- or down-arrow keys to highlight Setup 
    and press ENTER. Use the number buttons on the remote to enter the Setup menu passcode 
    when prompted and press ENTER again. Then, press MENU on the remote control. 
    Lamp Power: Select Lamp Power from the Setup Menu to adjust the lamp output level. You 
    can choose to run the lamp as bright as possible (200W; this is the default setting) or you can 
    choose the lower (170W) setting. Generally, lower lamp output prolongs the life of the lamp, 
    but decreases brightness. 
    Lamp Hours: When you replace the projector lamp (refer to Lamp Replacement on 
    page 63), you should also reset the lamp timer. To do this, select Lamp Hours from the Setup 
    menu. Press the right-arrow key on the remote to highlight “Yes,” then press ENTER to 
    confirm the reset. 
    Fan Mode: Select Fan Mode from the Setup Menu to control the operation of the projector’s 
    cooling fan. 
    In most cases, the default Fan Mode (Normal) will maintain the correct operating 
    temperature. If the lamp frequently turns off due to overheating, or in certain high-altitude 
    operating environments, you may need to change this setting to Hi. Altitude or Manual. 
    To manually set the fan speed, select Manual and press ENTER. Then, use the on-screen 
    slidebar to adjust the speed. 
    Background Color: Press the  or  button to select the image Background Color (black, 
    blue or gray). The Background Color appears when no incoming signal is present. 
    PIP: To enable or disable the picture-in-picture (PIP) feature, highlight PIP in the Setup menu 
    and press  or  to select On or Off. 
    Information
    Source HDMI 1
    Resolution 1920x1080
    Aspect Ratio 16:9
    Picture Memory ISF Night
    Lamp Hours 450
    Serial VIP65VM0735001
    You can also press INFO on the Vision 65/75 remote control unit (Figure 
    2-4) to display this information.Tip
    Setup
    Lamp Power 200 Watts
    Lamp Hours >
    Fan Mode Normal
    Background Color Black
    PIP Off
    VAC                   0
    12-volt Trigger Normal
    V. Correction   0
    Amplitude >
    Auto Off 0
    Default
    You only need to enter the Setup menu passcode the first time you select 
    that menu after turning on the projector.
    Reset the Lamp Timer ONLY after you replace the lamp. Otherwise, the 
    reported “Lamp Hours” will be inaccurate. 
    Do not exceed the recommended lamp life of 2000 hours. An old lamp 
    becomes increasingly fragile and prone to sudden failure. 
    Note
    Note
    WARNING 
    						
    							Operation
    58 Vidikron Vision Model 65/Model 75 Installation/Operation Manual
    VAC: Use the VAC control to increase or decrease the V² Aperture Control setting. VAC lets 
    you control the aperture or iris size (the physical opening through the lens; similar to an 
    “f-stop” on a camera). Doing so allows you to optimize brightness and contrast according to 
    the amount of ambient light in the viewing area. 
    Use a higher setting for rooms with a lot of ambient light. Use a lower setting for more 
    “theater-like” viewing conditions (little or no ambient light). 
    12-volt Trigger: Select 12-volt Trigger from the Setup menu to configure the 12-volt trigger 
    output. 
     Set the 12-volt Trigger to Normal if you want the trigger to activate when the projector is 
    turned on (for instance, if the trigger is controlling a retractable screen). 
     Set the 12-volt Trigger to Cinema if you want the trigger to activate when the Cinema or 
    IntelliWide 2.35 aspect ratio is selected. Choose this setting if your Vision 65/75 is 
    equipped with the Vidikron CineWide with AutoScope system. 
    V. Correction: To achieve the proper image geometry with the secondary anamorphic lens, 
    select 
    V. Correction from the Set Up menu. Then, use the  or  button to change the 
    native aspect ratio of the display, in small increments. 
    Amplitude: The Amplitude menu allows you to fine-tune the aspect ratio by compressing it 
    horizontally or vertically, in small increments. This can be useful if your projector is equipped 
    with an anamorphic lens. 
    The Horizontal control adjusts the image width while keeping the height constant. Similarly, 
    the Vertical control adjusts the image height while keeping the width constant. 
    Auto Off: When using the Vision 65/75 with a computer, use the Auto Off feature to have 
    the Vision 65/75 go into standby mode when no source signal is present on the current 
    input. (A warning message appears on-screen for approximately eight seconds before this 
    occurs.) Select an Auto-Off interval of from five to 30 minutes, in five-minute increments. To 
    return to normal operating mode from the Auto Off standby mode, select the input with the 
    remote control or operate your computer.
    When Auto Off is disabled, the Vision 65/75 remains in normal operating mode, regardless of 
    the presence or absence of an input sync signal. 
    Default: To restore all Setup Menu options to their factory-default values, select Default and 
    press the  button to highlight “Yes.” Then, press ENTER.
    1. If the computer is turned off or not properly connected to the Vision 
    65/75, the system is set to the off state.
    2. For instructions on using the computers power management features, 
    refer to the instructions for your computer. 
    Note 
    						
    							Operation
    Vidikron Vision Model 65/Model 75 Installation/Operation Manual 59 
    ISFTo access the ISF Calibration menu, select ISF from the Main Menu and press ENTER. Use the 
    number buttons on the remote control to enter the ISF Calibration menu passcode when 
    prompted and press ENTER again. Then, press MENU on the remote control. 
    Picture Memory/Copy Settings: These settings are described in the Picture Adjust section 
    (page 46).  
    Brightness/Contrast/Color/Tint/Sharpness/Color Temperature: These settings are 
    described in the 
    Picture Adjust section (refer to page 46). 
    White Balance: To remove any trace of color from the white areas of the projected image, 
    select the “Custom
     1” or “Custom 2” Color Temperature. Then, choose White Balance from 
    the ISF menu and press ENTER. 
    •Gain: Use the Gain controls to correct color imbalances in the bright areas of the image. A 
    good way to do this is to use a test pattern consisting mostly of solid white areas, such as 
    an 80 IRE “window” pattern. If the white areas contain traces of red, green or blue, 
    decrease the Gain for that color.
    • Offset: Use the Offset controls in the White Balance sub-menu to correct color imbalances 
    in the dark areas of the image. A good way to do this is to use a test pattern consisting 
    mostly of dark gray areas, such as a 30 IRE “window” pattern. If the gray areas contain 
    traces of red, green or blue, decrease the Offset for that color.
    The Gain controls increase or decrease the full-scale input range; the Offset controls shift 
    the entire range, resulting in a change in brightness. 
    Figure 4-8 shows how the Gain and 
    Offset controls interact with each other. 
    Figure 4-8. Gain and Offset
    ISF
    Picture Memory ISF Night
    Copy Settings >
    Brightness 50
    Contrast 50
    Color 50
    Tint 0
    Sharpness 5
    Color Temperature 6500
    White Balance >
    Advanced Options >
    Reset to Defaults
    This menu should be used by ISF-certified technicians only. 
    The Picture Memory selection you make here is retained when the projector 
    is powered off, then on again. 
    Note
    Note
    GAIN 1.0
    0
    0          1023
    ) V (   E G N A R   T U P N I
    0.5
    OFFSET = 0
    OFFSET = 512 OFFSET = 1023 OFFSET = 0 OFFSET = 1023
    OFFSET = 512 
    						
    							Operation
    60 Vidikron Vision Model 65/Model 75 Installation/Operation Manual
    Advanced Options: For more precise control over picture quality, select Advanced Options 
    from the ISF menu and press ENTER. 
    •Image Enhance: The Image Enhance menu gives you options for improving the quality of 
    standard-definition, 480i images. (For 480p and higher-definition images, the controls in 
    this menu are disabled.) Keep in mind that these controls add frequencies that are not 
    present in the original signal, and may make images appear “noisy” if misused. 
    DNR: Use the  or  button to adjust the Digital Noise Reduction (DNR). DNR is useful 
    for clearing up noisy images from interlaced SD sources. Adjust as desired, keeping in 
    mind that reducing noise (which reduces high frequencies) may also soften the image. 
    Detail Enhance: Use the Detail Enhance control to improve the apparent horizontal 
    and/or vertical resolution of the image. 
    Luma Enhance: Use the Luma Enhance control to improve the apparent brightness of 
    the image. 
    Chroma Enhance: This control adds chroma (color information) to the input signal and 
    can make colors appear more vibrant and saturated. 
    •Black Threshold: This control compensates for incoming elevated black levels present in 
    certain video signals, and ensures that blacks in the display are neither “crushed” (where 
    dark grays appear black) nor excessively elevated (where blacks appear dark gray). By 
    default, the projector automatically determines the best setting according to the type of 
    incoming video signal: 
    0 IRE: Used for DVD output with “enhanced black,” SECAM, most PAL standards and 
    Japanese NTSC. 
    7.5 IRE: Used for most NTSC video signals. 
    For some types of video, you may want to override the setting. Generally, if black appears 
    crushed when brightness = 30, choose “0 IRE.” If black appears excessively elevated, use 
    “7.5 IRE.” 
    •Gamma Selection: The normal gamma setting of 2.2 is correct for almost all signals and 
    conditions. If excess ambient light washes out the image and it becomes difficult or 
    impossible to see details in dark areas, lower the gamma setting to compensate. This will 
    improve contrast while maintaining good details for blacks. Conversely, if the image is 
    washed out and unnatural, with excessive detail in black areas, increase the setting. Again, 
    good gamma improves contrast while maintaining good details for blacks and whites. 
    Generally, higher Gain settings reduce the image contrast; higher Offset 
    settings reduce the image brightness.Note 
    						
    							Operation
    Vidikron Vision Model 65/Model 75 Installation/Operation Manual 61 
    •Advanced Color Enhance (ACE): Use the Advanced Color Enhance (ACE) controls to 
    customize the stored color space characteristics. To do this, use the  or  button to 
    select a component color (Red, Green, Blue, Yellow, Cyan or Magenta). 
    For each component color, you can adjust the following: 
    Limit: This slidebar adjusts the intensity – also known as luminance – of a given color. 
    Saturation: This slidebar adjusts the color saturation level – the amount of that color in 
    a video image. Lower settings produce less saturated colors; a setting of “0” removes 
    that color from the image entirely. If the saturation is too high, that color will be 
    overpowering and unrealistic. 
    To restore the color space settings to their factory-default values, select Reset to Defaults 
    and press ENTER. 
    •Gamut: Under most conditions, the White Balance and Advanced Color Enhance (ACE) 
    controls in the Calibration menu are adequate for producing accurate and realistic colors 
    from a variety of sources. 
    In rare cases, though, you may need more precise control over the Vision 65/75 display 
    color gamut (range). For example, you may require a unique color gamut for a given 
    projector or application. 
    The Vision 65/75 enables you to define the precise hue of each primary color component 
    (white, red, green and blue) used to generate the millions of colors produced in displays. 
    You do this by specifying x/y coordinates and luminance values for each primary color 
    component. 
    The x and y coordinates for each color define its location on the standard CIE chromaticity 
    graph, shown in 
    Figure 4-9. (CIE stands for “Commission Internationale de l’Éclairage” 
    (International Commission on Illumination), the organization responsible for color 
    measurement and management standards.) 
    Figure 4-9. CIE 1931 Chromaticity Diagram
    0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0.0 0.1 0.2
    0.3 0.4
    0.5 0.6
    0.7
    0.8 0.9 1.0
    x y
    20002222 2500 2857 3333 4000 5000 5714 6667 8000 10000D50D65D93 
    						
    							Operation
    62 Vidikron Vision Model 65/Model 75 Installation/Operation Manual
    Changing either or both of these numbers changes the hue of the color and relocates the 
    “triangle” for possible colors. For example, changing the x/y coordinates for red moves the 
    color closer to either orange or violet, which in turn affects all displayed colors having a 
    red component.
    To adjust the gamut:
    1. Select Gamut from the Advanced Options menu and press ENTER. 
    2. To do an automatic gamut adjustment, highlight “Enter” and press ENTER. If further 
    calibration is necessary, continue with the next step. 
    3. Highlight “Settings” and press  or  to select “Manual.” 
    4. Highlight “White” and press ENTER. The Vision 65/75 displays a white field on the screen. 
    5. Using the color analyzer, measure the x and y coordinates for about 15 seconds. Make a 
    note of the results. 
     6. Press EXIT or ENTER.
    7. Highlight “White” and press .
    8. Press ENTER to select the first digit of the x coordinate value for White (obtained in  
    Step 5).
    9. Press  or  repeatedly to set the digit.
    10. Press  to select the next digit; use the  and  buttons to change it.
    11. Repeat Step 10 for the third digit.
    12. Press ENTER. 
    13. Press  to highlight the “y” coordinate value for White. Then, press ENTER to select the 
    first digit. 
    14. Repeat Steps 9 through 12 to set the “y” coordinate value for White. 
    15. Press  to highlight the “Y” coordinate value. Then press ENTER to select the first digit. 
    16. Repeat Steps 9 through 12 to set the “Y” coordinate value for White. 
    17. Press EXIT.
    18. Repeat Steps 4 through 17 for Red, Green, Blue and D. White (Desired White). 
    19. Highlight “Save” and press ENTER. 
    To undo the effects of a previous calibration, highlight “Settings” and press  or  to select 
    “Default.” 
    Reset to Defaults: To restore the ISF default image settings for the current input source 
    ONLY, select 
    Reset to Defaults and press the  button to highlight “Yes.” Then, press ENTER.
    To perform these adjustments, you will need a color analyzer (Sencore 
    ColorPro 5000 software and ColorPro III sensor, or equivalent). Note
    Gamut
    Settings Manual
    White x:312 y:329 Y:045
    Red x:640 y:330 Y:015
    Green x:300 y:600 Y:022
    Blue x:150 y:060 Y:018
    D. White x:312 y:329 Y:045
    Enter
    Save
    Color Temp. 6500
    White x:000 y:000 Y: 000 
    						
    							Vidikron Vision Model 65/Model 75 Installation/Operation Manual 63 
    5.1 
    Lamp Replacement
    The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or 
    sooner if a noticeable degradation in brightness occurs. Contact your Vidikron dealer to 
    obtain a replacement lamp.
    1. Turn off the projector and unplug the power cord. 
    Allow the projector to cool down for 
    approximately 45 minutes prior to removing the 
    lamp assembly for replacement.
    2. Loosen the three captive screws from the lamp 
    cover.
     
     
    3. Remove the lamp cover.  
     
     
     
     
     
     
    4. Remove the two lamp assembly mounting screws. 
     
     
     
     
     
     
    5. Grasp the lamp assembly handle and pull gently, 
    removing the lamp module from the projector 
    housing.
    6. Install the new lamp module and replace the two 
    screws. 
     
     
     
    7. Replace the lamp cover at the right side first and 
    secure it with the two screws.
    8. Turn on the power and select Lamp Hours from the 
    Setup menu to reset the lamp timer (refer to Lamp 
    Hours on page 57). 
    5Maintenance and Troubleshooting 
    						
    							Maintenance and Troubleshooting
    64 Vidikron Vision Model 65/Model 75 Installation/Operation Manual
    5.2 
    Troubleshooting Tips
    Table 5-1 provides some general guidelines for troubleshooting problems you may 
    encounter with the Vision 65/75. If the suggested solutions fail to resolve the problem or if 
    you encounter an issue not described here, please contact Vidikron Technical Support. 
    Table 5-1. Troubleshooting Chart 
    SymptomPossible Cause(s)Solution
    The projector does not turn on.  The Vision 65/75 is not 
    plugged in or the AC outlet 
    is not active. 
     The main power switch (at 
    the rear of the projector) is 
    off. 
     Lamp cover is not securely 
    attached.  Ensure that the Vision 
    65/75 is plugged in and 
    that the AC outlet is active. 
     Turn on the power switch.  
     
     Securely attach the lamp 
    cover.
    The projector does not turn 
    back on after it was powered 
    off.  The projector will not turn 
    on for two minutes after 
    power-off, to protect the 
    lamp.  Wait until the Vision 65/75 
    completes its cool-down 
    (POWER LED lights solid 
    orange). 
    The remote control does not 
    work correctly.  The batteries have run out.  Replace the batteries. 
    The projector is on and OSD 
    menus appear, but there is no 
    video image on-screen.  Incorrect source selection.
     Source component is not 
    turned on. 
     Source component is 
    connected incorrectly or 
    not at all.  Select the correct source. 
     Turn on the source.  
     Check cable connection 
    from source component to 
    projector. 
    A projected image from a DVD 
    is split or otherwise scrambled.  DVD player is connected to 
    the Component input and 
    set to progressive scan 
    mode.  Turn off progressive scan 
    on the DVD player. 
    Image is blurred.  The lens is not correctly 
    focused.  Adjust the focus with the 
    remote control. 
    Image is too bright and/or 
    lacks definition in the bright 
    areas of the image.  Contrast is set too high.  Lower the contrast setting. 
    Image appears “washed out” 
    and/or dark areas appear too 
    bright.  Brightness is set too high.  Lower the brightness 
    setting. 
    Colors in the image are 
    swapped; for example, reds 
    appear blue or vice versa.  The Red/Pr, Green/Y or 
    Blue/Pb outputs from the 
    source are connected to the 
    wrong inputs on the Vision 
    65/75. Ensure that the source 
    outputs are connected to 
    the correct Vision 65/75 
    input. 
    POWER LED lights solid red. Internal failure.  Please contact your 
    Vidikron dealer for 
    assistance.  
    						
    All Vidikron manuals Comments (0)