Page 21
18 Weather Channel Scan The BC244CLT allows you to search from 7 pre-programmed NOAA channels for your local NOAA weather channel. Press WXto find the active weather channel in your area. It is possible that your area is covered by more than one weather station. When you press WX, the BC244CLT immediately finds an active broadcast. If the broadcast sounds weak and distant, press WX again to look for a closer station. To exit Weather Channel Scan mode, press SCAN, MANUAL, or ON/OFF. Do...
Page 22
19 Priority Scanning Priority Scan is like a dual watch function. When you activate Priority Scan mode, the scanner keeps track of the activity on the priority channel while scanning the other channels. A constant P PR RI I appears on the display Every two seconds, the scanner checks the priority channel for activity. If a signal is found, the scanner remains on the priority channel until the transmission ends. If the signal stops for more than two seconds, normal scan operation resumes. To Set the...
Page 23
20 3. Press and hold PRIORITY until a beep sounds. The P PR RI I indicator appears in the display and Pindicator appears to the left of the selected channel. To enter the Priority Scan Mode When in Scan or Manual mode, press PRIORITY. The P PR RI I indicator appears in the display. To exit the Priority Scan Mode Press PRIORITYagain. The P PR RI I indicator goes out. Channel Lockout You can lock out a channel so it is not scanned. Channel Lockout does not erase the frequency from the channel....
Page 24
21 In the Manual mode, press LOCKOUT to lock out the displayed channel. Pressing LOCKOUTdoes not advance to the next channel in Manual mode. L L/ /O O appears in the display to indicate the displayed channel is locked out. Whenever you want to search for channels that are locked out, press MANUALrepeatedly to go through all 30 channels. If a channel is locked out, the L L/ /O O indicator appears. Restore a Locked Out Channel To unlock a channel so that it can be monitored during...
Page 25
22 Restore all Locked Out Channels To unlock all channels, you must be in Manual Mode. 1. Press MANUAL. 2. Press and hold LOCKOUTuntil a beep sounds. The L L/ /O O indicator goes out on any channel previously locked out. BC244clt.qxd 3/11/99 12:00 PM Page 22
Page 26
23 Helpful Hints General UsenTurn the scanner off before disconnecting the power.nAlways write down the programmed frequencies in the event of scanner memory loss. nIf scanner memory is lost, simply reprogram each channel. The display shows A Al ll l L Lo oc c O Ou ut t when there has been a memory loss. nAlways press each keypad button firmly until you hear the entry tone for that key. Location nIf your scanner receives strong interference or electrical noise, relocate the scanner or its antenna...
Page 27
24 ProblemSolution nCheck the connections at both ends of the AC Adapter. nTurn on the wall switch of your room. You could be using an outlet controlled by the wall switch. nMove the AC Adapter to another wall outlet. nScanner won’t power up. nPoor reception.nCheck antenna connection. nMove the antenna. nIf the programmed frequency is higher than 406MHz, a shorter antenna length may improve the reception. nRelocate the scanner. nYou may be in a fringe area. This could require an optional multi-band...
Page 28
25 If you still cannot get satisfactory results and want additional information, or to return the unit for service, please call the Uniden Parts and Service Division at the number shown below. ProblemSolution nScan won’t stop.nAdjust squelch to the threshold (Page 11). nCheck the antenna connection. nCheck to see if many of the channels are locked out. If so, the scanner has less chance of finding an active channel. nReview each channel’s frequency to see if it is correct and no memory has been lost....
Page 29
26 Certified in accordance with FCC Rules and Regulations Part 15 Sub-part C as of date of manufacture. Band Coverage: 10 bands Frequency Coverage: 29.0-29.7 MHz 10 Meter Amateur Band 29.7-50.0 MHz Low Band 50.0-54.0 MHz 6 Meter Amateur Band 137-144 MHz Military Land Mobile 144-148 MHz 2 Meter Amateur Band 148-174 MHz VHF High Band Above bands in 5 kHz steps 406-420 MHz Federal Government 420-450 MHz 70cm Amateur Band 450-470 MHz UHF Standard Band 470-512 MHz UHF “T” Band Above bands in 12.5kHz steps...
Page 30
27 WARRANTOR:UNIDEN AMERICA CORPORATION (“Uniden”) ELEMENTS OF WARRANTY: Uniden warrants, for one year, to the original retail owner, this Uniden Product to be free from defects in materials and craftsmanship with only the limitations or exclusions set out below. WARRANTY DURATION:This warranty to the original user shall terminate and be of no further effect 12 months after the date of original retail sale. The warranty is invalid if the Product is (A) damaged or not maintained as reasonable or...