    							Deleting a Programmed Frequency 
    (programming 000.0000)
    You can erase a programmed frequency in a channel. To do
    this, find and display  000.0000, and then program
    000.0000 into its channel.
    1. Find and display 000.0000 on the screen
    You can choose either of two ways:
    a. If there is an open channel in the scanner, find
    000.0000 in an open channel:
    Press the desired bank key (Private, Police, or
    Fire/EMS), and then 
    [HOLD], and use [UP]and
    [DOWN]to scroll through the bank to find an open 
    channel, 000.0000, then press 
    [PROG]. CH is 
    displayed and it is blinking.
    – OR –
    b. If all channels are programmed, find 000.0000 from the
    Search/Program Mode. 
    Every search band has one 000.0000 display included
    between the band limits. It can be displayed only in the
    Program Mode (after pressing 
    [PROG]and CH is 
    blinking in the display).
    1) Select Search band by pressing 
    [BAND]in the Search
    Mode, for example band 50-54.
    2) Press 
    [HOLD]to stop searching.
    3) Press 
    [PROG]to go into Program Mode.
    4) Use 
    [UP]or [DOWN]to display the lowest frequency
    (50.0000) or the highest frequency (54.0000).
    5) Press 
    [UP]once for the highest frequency, or [DOWN]
    once for the lowest frequency to display 000.0000 with
    blinking CH.
    27
    UB317Z (BC350C) 0916  9/16/03  12:43 PM  Page 27 
    						
    							28
    2. Program 000.0000 into its Channel
    For example to erase a programmed frequency in channel 13
    of the Private bank:
    1) Press 
    [PRIVATE]while this
    screen appears. To display
    this screen, see step 1 above.
    PRIVATE appears in the 
    display.  
    2 screens alternate to indicate
    that Channel 1 is ready to be 
    programmed. 
    2) Use 
    [UP]or [DOWN]to select
    Channel 13. Now, Channel 13
    is ready to be programmed. To
    cancel programming, press
    [BAND]. 
    3) Press 
    [PROG]to end 
    programming. 
    The frequency of Channel 13
    is erased and now it is an
    open channel. L/O appears on
    the display because the 
    scanner locks out all open
    channels automatically.
    Program Lock Feature
    The BC350C has a program lock feature “Memory Lock” to
    prevent accidental programming entries or unauthorized 
    pro-gramming. Simply turn on the MEMO LOCK switch on the
    rear panel to disable 
    [PROG]and protect your programmed
    frequencies in memory.
    UB317Z (BC350C) 0916  9/16/03  12:43 PM  Page 28 
    						
    							29
    General Use
    •Turn the scanner off before disconnecting the power.
    •Always press each keypad button firmly until you hear the
    entry tone for that key entry.
    Location
    •If strong interference or electrical noise is received, relocate
    the scanner or its antenna away from the source of the
    noise. A higher elevation, if possible, may provide better
    reception. You might also try changing the height or angle
    of the telescoping antenna.
    •Do not use the scanner in high-moisture environments such
    as the kitchen or bathroom.
    •Avoid placing the unit in direct sunlight or near heating 
    ele-ments or vents.
    Cleaning
    •Disconnect the power to the unit before cleaning.
    •Clean the outside of the scanner with a mild detergent.
    •To prevent scratches, do not use abrasive cleaners or 
    solvents. Be careful not to rub the LCD window.
    •Do not use excessive amounts of water.
    Repairs
    •Do not attempt any repair. The scanner contains no 
    service-able parts. Contact the Uniden Customer Hotline at
    1-800-297-1023 or take it to a qualified repair technician.
    Birdies
    All radios are subject to receiving undesired signals or birdies.
    If your scanner stops during Search Mode and no sound is
    heard, it may be receiving a birdie. Birdies are internally-gen-
    erated signals inherent in the electronics of the receiver. If the
    interference is not severe, you might be able to turn 
    [SQ]
    counterclockwise to cut out the birdie. Or, press [SEARCH]to
    resume searching. (Known birdie frequencies for the BC350C
    are: 108.785, 462.5625, 485.9, 814.0, 932.825, 938.375, and
    940.9 MHz)
    Helpful Hints
    UB317Z (BC350C) 0916  9/16/03  12:43 PM  Page 29 
    						
    							If your BC350C is not performing properly, try the steps listed
    below.
    Scanner won’t work
    •Check the connections at both ends of
    the AC Adapter.
    •Turn on the wall switch of your room.
    You could be using an outlet controlled
    by the wall switch. Move the AC
    Adapter to another wall outlet.
    •Check the connections at both ends of
    the DC cord or cigarette lighter cord.
    •Check to see if the fuse is blown.
    •Make sure the ignition key in your 
    vehicle is at the Accessory position.
    •Make sure the power switch is turned
    on.
    •Check the antenna and its connection.
    •Move the scanner.
    •You may be in a fringe area. This may
    require an optional multi-band antenna.
    Check with your dealer or local 
    electronics store.
    •Adjust the Squelch Control.
    •Check the Antenna Connection.
    •Review each channels frequency to
    see if it is still stored in memory and is
    correct.
    •Check and adjust Squelch (see
    Adjusting the Squelch on page 18).
    •Check the antenna connection.
    •Check to see if all channels are locked
    out.
    •It is possible that none of the 
    programmed frequencies are active at
    the time. Try the band search.
    30
    Troubleshooting
    PROBLEM PROBLEM
    Improper reception
    Weather scan wont
    work
    Scan won’t stop
    UB317Z (BC350C) 0916  9/16/03  12:43 PM  Page 30 
    						
    							31
    Scan won’t start
    •Press the bank key again.
    •Adjust the Squelch Control.
    •For the Private bank scanning program
    frequencies into the bank before using.
    •Adjust the Squelch Control.
    •Check the antenna connection.
    •Scan or search must first be stopped.
    •MEMO LOCK Switch is ON.
    •Call our customer hotline at 
    1-800-297-1023.
    PROBLEM PROBLEM
    Search won’t start
    PROGRAM key
    won’t work
    If you still have a
    problem
    UB317Z (BC350C) 0916  9/16/03  12:43 PM  Page 31 
    						
    							Banks: Total 7 banks:6 Service banks and
    1 Private bank.
    POLICE:1769 programmed plus 30
    programmable channels
    FIRE/EMS:280 programmed plus 20
    programmable channels
    AIR:1,519 programmed.
    (All aircraft)
    MRN:51 Programmed. (All Marine)
    WX:10 programmed.
    (8 for NOAA weather service
    and 2 for CANADA)
    CB:40 programmed.
    PRIVATE:50 channels fully user-
    programmable
    (Total 100 programmable
    channels)
    Search Band: Total 13 Search bands:
    (All FM except aircraft band and CB (AM))
    Band              Frequency Coverage       Mode       Steps
    25 – 28 25.0000 to 27.9950 MHz AM 5 kHz
    28 – 30 28.0000 to 29.7000 MHz FM 5 kHz
    30 – 50 30.0000 to 49.9950 MHz FM 5 kHz
    50 – 54 50.0000 to 54.0000 MHz FM 5 kHz
    108 – 137 108.0000 to 136.9875 MHz AM 12.5 kHz
    137 – 144 137.0000 to 143.9950 MHz FM 5 kHz
    144 – 148 144.0000 to 147.9950 MHz FM 5 kHz
    148 – 174 148.0000 to 174.0000 MHz FM 5 kHz
    406 – 420 406.0000 to 419.9875 MHz FM 12.5 kHz
    420 – 450 420.0000 to 449.9875 MHz FM 12.5 kHz
    450 – 470 450.0000 to 469.9875 MHz FM 12.5 kHz
    470 – 512 470.0000 to 512.0000 MHz FM 12.5 kHz
    806 – 956 806.0000 to 823.9875 MHz FM 12.5 kHz
    849.0125 to 868.9875 MHz
    894.0125 to 956.0000 MHz
    Sensitivity:    12 dB SINAD.
    (Nominal)
    0.8 µV 25.000 - 28.000 MHz
    0.3 µV 28.000 - 54.000 MHz
    0.4 µV 137.000 - 174.000 MHz
    0.3 µV 406.000 - 512.000 MHz
    0.6 µV 108.000 - 136.9875 MHz
    0.5 µV 806.000 - 956.000 MHz
    32
    Technical Specifications
    UB317Z (BC350C) 0916  9/16/03  12:43 PM  Page 32 
    						
    							Scan Rate:100 channels per second
    Search Rate:100 steps per second / 
    300 steps per second 
    (5 kHz steps band only)
    Scan Delay:2 seconds
    Audio Output:Max 2.7 W
    Antenna:50 ohms (Impedance)
    Operating Temperature:– 20ºC (– 4ºF) to + 60ºC (+ 140ºF)
    Size:5-3/16(W) x 5-3/4(D) x 1-5/8(H)
    Weight:1 lb 6.5 oz.
    Certified in accordance with FCC Rules and Regulations Part
    15 Sub-part C as of date of manufacture.
    Features, specifications, and availability of optional 
    accessories are all subject to change without notice.
    33
    UB317Z (BC350C) 0916  9/16/03  12:43 PM  Page 33 
    						
    							Important:Evidence of original purchase is required for
    warranty service.
    WARRANTOR:UNIDEN AMERICA CORPORATION  (Uniden)
    ELEMENTS OF WARRANTY:Uniden warrants, for one year, to the
    original retail owner, this Uniden Product to be free from defects in
    materials and craftsmanship with only the limitations or exclusions set
    out below.
    WARRANTY DURATION:This warranty to the original user shall 
    terminate and be of no further effect 12 months after the date of 
    original retail sale. The warranty is invalid if the Product is (A) 
    damaged or not maintained as reasonable or necessary, (B) modified,
    altered, or used as part of any conversion kits, subassemblies, or any
    configurations not sold by Uniden, (C) improperly installed, (D) 
    serviced or repaired by someone other than an authorized Uniden
    service center for a defect or malfunction covered by this warranty,
    (E) used in any conjunction with equipment or parts or as part of any
    system not manufactured by Uniden, or (F) installed or programmed
    by anyone other than as detailed by the owner’s manual for this 
    product.
    STATEMENT OF REMEDY:In the event that the product does not
    conform to this warranty at any time while this warranty is in effect,
    warrantor will either, at its option, repair or replace the defective unit
    and return it to you without charge for parts, service, or any other
    cost (except shipping and handling) incurred by warrantor or its 
    representatives in connection with the performance of this warranty.
    Warrantor, at its option, may replace the unit with a new or 
    refurbished unit. THE LIMITED WARRANTY SET FORTH ABOVE IS
    THE SOLE AND ENTIRE WARRANTY PERTAINING TO THE
    PRODUCT AND IS IN LIEU OF AND EXCLUDES ALL OTHER
    WARRANTIES OF ANY NATURE WHATSOEVER, WHETHER
    EXPRESS, IMPLIED OR ARISING BY OPERATION OF LAW,
    INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTIES
    OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
    PURPOSE. THIS WARRANTY DOES NOT COVER OR PROVIDE
    FOR THE REIMBURSEMENT OR PAYMENT OF INCIDENTAL OR
    CONSEQUENTIAL DAMAGES. Some states do not allow this
    exclusion or limitation of incidental or consequential damages so the
    above limitation or exclusion may not apply to you.
    LEGAL REMEDIES:This warranty gives you specific legal rights,
    and you may also have other rights which vary from state to state.
    This warranty is void outside the United States of America and
    Canada.
    PROCEDURE FOR OBTAINING PERFORMANCE OF WARRANTY:If, after following the instructions in the owner’s manual you are
    certain that the Product is defective, pack the Product carefully
    (preferably in its original packaging). The Product should include all
    parts and accessories originally packaged with the Product. Include
    evidence of original purchase and a note describing the defect that
    has caused you to return it. The Product should be shipped freight
    prepaid, by traceable means, to warrantor at:
    Uniden America  Corporation
    Parts and Service Division
    4700 Amon Carter Blvd.
    Fort Worth, TX 76155
    (800) 297-1023, 8 a.m. to 5 p.m. CST, Monday through Friday
    34
    One Year Limited Warranty
    UB317Z (BC350C) 0916  9/16/03  12:43 PM  Page 34 
    						
    							35
    UB317Z (BC350C) 0916  9/16/03  12:43 PM  Page 35 
    						
    							UB317Z (BC350C) 0916  9/16/03  12:43 PM  Page 36 
    						
    All Uniden manuals Comments (0)

    Related Manuals for Uniden Bc350c Vhf Uhf Scanner Owners Manual