Page 101

User Defined Fleet Maps
Type I Programming Information
When a Type I system is designed, the address information
for all the IDs are divided into 8 equal sized blocks. When you
program your scanner to track a Type I system, you must
select a size code for each of these blocks. When you have
assigned a size code to all 8 blocks, you have defined the
Fleet Map for the system youre tracking. Each size code
determines the number of Fleets, Subfleets, and IDs each
block will have. For example, a size code of...

Page 102

98 Finally, for most public safety systems there are some size
codes which are more common. SIZE CODE 3 and SIZE
CODE 4 are probably the most common, followed by SIZE
CODE 10, SIZE CODE 11, and SIZE CODE 12.
Fleet Map Size Codes
Size Code Restrictions
If you select SIZE CODE 12, 13, or 14, there are some
restrictions as to which blocks can be used for these codes.
•SIZE CODE 12 can only be assigned to Blocks 0, 2, 4,
or 6.
•SIZE CODE 13 can only be assigned to Blocks 0 and 4.
•SIZE CODE 14 can only be...

Page 103

99
Event Code Standard Event Level (Siren Type) LCD DisplayWarning Watch Statement TestHurricane/Tropical Storm Warning HUW 0 HURRICANETsunami Warning TSW 0 TSUNAMICoastal Flood Warning CFW 0 COASTAL FLOODSpecial Marine Warning SMW 0 SPECIAL MARINEAvalanche Warning AVW 0 AVALANCHEVolcano Warning VOW 0 VOLCANOShelter In Place Warning SPW 0 SHELTERCivil Danger Watch CDA 0 CIVIL DANGERRadiological Hazard Watch RHA 0 RADIOLOGICALHazardous Material Watch HMA 0 HAZARDOUSWinter Storm Watch WSA 0 WINTER...

Page 104

100
Range Offset29.520 - 29.580 +0.1 MHz29.620 - 29.680 -0.1 MHz52.010 - 52.990 +1 MHz53.010 - 53.990 -1 MHz143.750 +4.375 MHz143.900 +4.25 MHz144.510 - 144.890 +0.6 MHz145.110 - 145.490 -0.6 MHz146.010 - 146.385 +0.6 MHz146.415 - 146.505 +1 MHz146.595 +1 MHz146.610 - 146.985 -0.6 MHz147.000 - 147.390 +0.6 MHz147.415 - 147.505 -1 MHz147.595 -1 MHz147.600 - 147.990 -0.6 MHz148.125 -4.375 MHz148.150 -4.25 MHz222.120 - 223.380 +1.6 MHz223.720 - 224.980 -1.6 MHz420.000 - 424.9875 +5 MHz425.000 - 429.9875 -5...

Page 105

101
CTCSS Frequency List (Hz)
DCS Tone  Code
67.0
91.5
118.8
156.7
210.771.9
94.8
123.0
162.2
218.174.4
97.4
127.3
167.9
225.777.0
100.0
131.8
173.8
233.679.7
103.5
136.5
179.9
241.882.5
107.2
141.3
186.2
250.385.4
110.9
146.2
192.888.5
114.8
151.4
203.5
023
051
114
143
174
245
266
332
411
452
506
612
703025
053
115
145
205
246
271
343
412
454
516
624
712026
054
116
152
212
251
274
346
413
455
523
627
723031
065
122
155
223
252
306
351
423
462
526
631
731032
071
125
156
225
255
311
356
431
464
532
632...

Page 106

102
1
2
3
4
5
6
7
8
9
0WEATHER
PUBLIC SAFETY
NEWS
TV BROADCAST
HAM RADIO
MARINE
RAILROAD
AIR
CB RADIO
FRS
RACING
SPECIAL
CHAIN SEARCH
1
2MONITOR
ALERT1: ONFIPS CODE 1
:
:
FIPS CODE15
ALL FILPS CODE1
2
3
4
5
6CHAIN SEARCH 
SEARCH RANGE
(RANGE NO. SELECT)
DELAY
ATTENUATOR
TONE DATA
AUTO STORE1: ON/ 2:OFF
1: ON/ 2:OFF
1: ON/ 2:OFF
1: CTCSS/ 2: DCS/ 3: OFF
1: ON/ 2:OFF
1
2
3
4
5RANGE
STEPS
MODE
ALPHA TAG
TRUNK 1 SERVICE OPTION
2: OFF
ENTER LOWER, ENTER UPPER
1: 5KHz/2: 7.5KH/3: 10KHz/4: 12.5KHz/
5: 25KHz/6:...

Page 107

103
1
 
2CONVENTIONAL
(CHANNEL SELECT)
TRUNK
(BANK SELECT)
1
2
3
4
5
6
 
7FREQUENCY
DELAY
TONE DATA
BEEP ALERT
ATTENUATOR
STEPS
MODEFREQUENCY
1: ON/ 2:OFF
1: CTCSS/2: DCS/ 3: OFF
1: ON/ 2:OFF
1: ON/ 2:OFF
1: 5KHz/ 2: 7.5KHz/ 3: 10 KHz/ 
4: 12.5 KHz/ 5: 25 KHz/ 6: 50 KHz/ 
7: 100 KHz/ 8: AUTO
1:AM/ 2:FM/ 3:WFM/ 4:NFMALPHA TAG1
2
 
3
 
4
 
 
5
 
 
6
7
8
 
8
9
9
0
0TRUNK TYPE
TRUNK CHANNEL
(CHANNEL SELECT)
TALK GROUP 
(ID NO. SELECT )
DELAY
 
 
ID LIST TAG
 
 
L/O ID REVIEW
ACTIVITY ID
I-CALL
(MOTOROLA/...

Page 108

104
1
2
3
4
5
 
 
6
7
8
 
9
 
0DIMMER
SCREEN MASK
KEY BEEP
ENTER LOCK
PC CONTROL
 
 
CLONE
D ATA  S K I P
SQ MODE
 
BANK TAG
(SELECT BANK)
P-25 CARD
BATTERY SAVEDIMMER LIGHT
DIMMER TIME
1: ON/ 2:OFF
1: ON/ 2:OFF
1: ON/ 2:OFF
1: 2400 bps / 2: 4800 bps / 
3: 9600 bps/ 4: 19200 bps/ 
5: OFF
MASTER / SLAVE
1: ON/ 2:OFF
1: CSQ/ 2: TONE SQ/ 
3: TONE SEARCH
1: ENABLE/ 2: DISABLE
1: ON/ 2: OFF1: HIGH/ 2: MEDIUM
1: 15SECONDS/ 2: INFINITE 3 SYSTEM OPTION
BC250D  11/6/2 11:37 AM  Page 104 

Page 109

105
One Year Limited Warranty
Important: Evidence of original purchase is required for warranty
service.
WARRANTOR: UNIDEN AMERICA CORPORATION (Uniden)
ELEMENTS OF WARRANTY: Uniden warrants, for one year, to the
original retail owner, this Uniden product to be free from defects in
materials and craftsmanship with only the limitations or exclusions 
set out below.
WARRANTY DURATION: This warranty to the original user shall
terminate and be of no further effect 12 months after the date of
original retail...

Page 110

BC250D  11/6/2 11:37 AM  Page 106 
Start reading Uniden Bc250d Widenband Scanner Owners Manual

Related Manuals for Uniden Bc250d Widenband Scanner Owners Manual

All Uniden manuals