Page 61
61 Programming Radio Systems When the scanner prompts Confirm?, press E to accept the settings. The scanner creates an empty LTR system, with a default name of System nnN L. nNn increments as you add new systems. L indicates that this is an LTR system. Next, refer to the appropriate section to set system-wide options. For most settings, you can accept the default. However, for the items in bold, you must enter informa- tion in order for your scanner to scan the system. • See “Editing the...
Page 62
62 Programming Radio Systems Setting Up a Channel Group 4 J EDIT GROUPJ E J 4 J NEW GROUPJ E The scanner creates a group with a default name of GROUP nn. nn increments by one for each new group you create within a system. Next, refer to the appropriate section to set group-wide options: • See “Entering/Editing the Group Name” on Page 71 • See “Setting the Group Quick Key” on Page 72 • See “Setting Group Lockout” on Page 72 • See “Deleting Groups” on Page 73 • See “Entering/Editing LTR Channels/...
Page 63
63 Programming/Editing Optional Settings Programming/Editing Optional SettingsThis section details the instructions for each of the optional programming steps referred to in “Programming Radio Systems” on Page 52. Use the instructions in the appropriate section to enter or edit a setting. System-Level Settings These settings apply to the entire system. Editing the System Name J Program SysteM J E 4 Select the system J E Edit Name J E Follow these steps to enter/edit the system name. 1. Rotate the...
Page 64
64 Programming/Editing Optional Settings Edit Sys Option J E 4 Set Quick KeyJ E After selecting this option, press 0-9 to assign the system to a quick key or press No to assign the system to no quick key, then press E. Hints: • You can assign as many systems to the same quick key as you want. • Preprogrammed systems are set to quick key 9. • To be scanned, a system’s quick key must be activated and the system must be unlocked. Setting System Lockout J program system J E 4 Select the system J E 4...
Page 65
65 Programming/Editing Optional Settings Notes: • If you select 0, the scanner stays on the system for a minimal time (only long enough to check current system activity). • The default setting is 2 seconds for each system. • For conventional systems, all unlocked channels will be scanned at least once regardless of this setting. • The scanner moves to the next system after the hold time expires, any current transmission ends, and the channel delay time expires. Setting the Channel Delay Time J...
Page 66
66 Programming/Editing Optional Settings ID Search - the scanner stops on any transmission for unlocked talk group IDs. Note: You can also change this setting by pressing Scan while scanning the system. Setting the Base Frequency/Step/Offset (Motorola UHF/VHF Systems Only) J program system J E 4 Select the system J E 4 Edit Sys Option J E 4 Edit Band Plan J E 4 Select Plan J Select a band plan (1, 2, or 3) J E 4 Input Base Freq J Input the base frequency J E 4 Select Step (5 kHz, 12.5 kHz, 25.0...
Page 67
67 Programming/Editing Optional Settings Notes: • This setting is ignored for AM channels. • The default setting for this feature is On. Editing the Fleet Map (Motorola Systems Only) J program system J E 4 Select the system J E 4 Edit Sys Option J E 4 Edit Fleet MapJ E For Motorola Type I systems, you must enter a system fleet map in order for the scanner to properly track and display talk group IDs. The fleet map is usually included in the same resource that provided system frequencies and talk...
Page 68
68 Programming/Editing Optional Settings Motorola systems use talk group IDs in multiples of 16. ID numbers that fall between these IDs indicate special status flags for the system. This setting determines how the scanner will handle IDs that are not multiples of 16. Select your setting then press E. Ignore - the scanner rounds all received IDs down to the next interval of 16. Yes - the scanner treats all received IDs as unique IDs. Note: The default setting is Ignore. Setting the End Code...
Page 69
69 Programming/Editing Optional Settings On - the scanner tracks I-calls. Press E to select. Off - the scanner ignores I-calls. Press E to select. Only - the scanner only tracks I-calls and ignores other radio traffic on the system. Press E to select. Note: The default setting is Off. Setting Emergency Alert (Motorola and EDACS Systems Only) J program system J E 4 Select the system J E 4 Edit Sys Option J E 4 Set EMERGENCY ALERT J E This setting determines how your scanner handles radio traffic that...
Page 70
70 Programming/Editing Optional Settings Notes: • The scanner defaults to AFS (agency, fleet, subfleet) format - the format used in most EDACS systems. • See “EDACS Trunking” on Page 25 for more information about the AFS format. Setting Control-Channel Only (Motorola Systems Only) J program system J E 4 Select the system J E 4 Edit Sys Option J E 4 Set C-CH OnlyJ E This setting determines the frequencies you need to enter for Motorola systems. Select your setting, then press E. Off - you must enter...