Page 11

11
F/C Settings
The F/C Settings screen is use to select the temperature display mode. F\
ahrenheit (F) or Celsius (C) are the two 
available modes.
F/C Settings
F/C Mode       F
Done+-
Change the Temperature Mode
1. Press the MENU button.
2. Scroll to User Settings and press the Select button.
3. Scroll to F/C Settings and press the Select button.
4. Press the plus (+) or minus (-) buttons to change the temperature mode. Select F for Fahrenheit or C \
for Celsius. 

Page 12

12
Sensor Calibration
The Sensor Calibration screen is used to change the temperature calibrat\
ion of the internal temperature sensor. 
The temperature calibration can be changed by +/- 7 degrees.
When the Sensor Calibration screen is selected, the current temperature \
calibration is displayed. In the example 
screen, the calibrated temperature is 77 and the number of degrees of offset being applied is 1.
Sensor Calibration
Internal    (77)      1
Done+-
Change the Sensor Calibration
1. Press the MENU...

Page 13

13
Backlite/Display
The Backlite/Display screen is used to set the backlight time-out and co\
ntrast.
Backlite Timeout is the time (in seconds) from the last button press to the backlight going out. The time-out can 
be set between zero (0) and one hundred and twenty (120) seconds. Thirty (30) is the default setting. When set 
to zero (0), the backlight will remain always on.
Contrast sets the contrast level of the LCD display. The contrast can be set between zero (0) and twenty (20). 
Ten (10) is the...

Page 14

14
Usage Graph
The Usage Graph shows daily heating and cooling runtime hours for a week.
Heating time (Hrs)
DoneCool
20
15
10
5Sun MonTueW edThuF riSat
The button in the lower right corner will change depending on what is being displayed. When the heating time 
is displayed, the button will read Cool. When the cooling time is displayed, the button will read Heat. Press the 
Heat/Cool button to display the heating/cooling time. 

Page 15

15
ESM Setpoints
Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is select-
ed in the Schedule Mode screen.
Energy Saving Mode Setpoings
ESM - Heat    65
ESM - Cool           80
Done+-
Adjust ESM Setpoints
1. Press the MENU button.
2. Scroll to ESM Setpoints and press the Select button.
3. To adjust the heat setpoint, scroll to ESM - Heat. Press the plus (+) or minus (-) buttons to adjust the setpoint.
4. To adjust the cool setpoint, scroll to ESM - Cool....

Page 16

16
ZWave Install
Z-Wave™ controllers from various manufacturers may support the Z-Wave™ Thermostat General V2 Device 
class used by the Trane Z-Wave™ Thermostat. The following procedure will allow the thermostat to be added to 
a Z-Wave™ network.
 ÎIf you are using a controller that is not a Schlage bridge, consult the instructions that came with the controller to find out 
how to enroll a new device.
Inclusion
1. Install a new, high-quality 9-volt battery into the bridge.
2. Hold the bridge within 6...

Page 17

17
ItemDescription
TZEMT400BB32Model Number
Ver: 01.00.10Firmware version
 ÎThis number may vary.
ZVER: 02.00.9Z-Wave version
 ÎThis number may vary.
ZNID: 004Z-Wave node ID
 ÎThis number may vary.
ZHID: 01.07.37.bdZ-Wave Home ID
 ÎThis number may vary.
System Type: StandardSystem type may be Standard or Heatpump
Fan Type: GasFan type may be Gas or Elect (electric)
Thermostat Info
Done
TZEMT400BB32 Ver: 01.00.10
ZVER: 02.00.9  ZNID: 004
ZHID: 01.07.37.bd
System Type:  Standard
Fan Type:  Gas
Thermostat...

Page 18

18
Installer Settings
 ÎThe Installer Settings screen is a hidden screen designed for installer \
use only. Do not change any settings in this 
screen unless you are a qualified service technician.
Installer Settings
Display Lock N
System Settings
Max Heat SP  90
Min Cool SP  60
Done+-
 ÎChanging these settings will affect the operation of the heating/cooling system.
To view and edit these settings:
1. Press the MENU button.
2. Press and hold the two middle buttons simultaneously until the Installer...

Page 19

19
System Settings
 ÎChanging these settings will affect the operation of the heating/cooling system.
To view and edit these settings:
1. Press the MENU button.
2. Press and hold the two middle buttons simultaneously until the Installer Settings menu is displayed.
3. Scroll to System Settings and press the Select button.
4. Scroll to the setting you want to change. Press the plus (+) or minus (-) button to adjust the setting.
5. Press the Done button when you are finished.
 ÎNote on Delta Settings: The...

Page 20

20
Mechanical Settings
 ÎChanging these settings will affect the operation of the heating/cooling system.
To view and edit these settings:
1. Press the MENU button.
2. Press and hold the two middle buttons simultaneously until the Installer Settings menu is displayed.
3. Scroll to System Settings and press the Select button.
4. Scroll to Mechanical Settings and press the Select button.
5. Scroll to the setting you want to change. Press the plus (+) or minus (-) button to adjust the setting.
6. Press the...