Page 31
This section describes the installation proceduresnecessary to ensure proper operation of the PERCEPTION system. When the PERCEPTION system is re- ceived,examine all packages and make careful note of any visible damage. If any damage is found, bring it to the attention of the delivery carrier and make the proper claims. Check the PERCEPTION system against the purchase order and packing slip. If it is deter- mined that equipment is missing, contact your supplier imm~djately.After unpacking (before the...
Page 32
Conventional telephone-500 ohms (including telephone)AI .” :/. 1 Attendant Console-1000 cable feet (24 AWG) Acceptable cable for all telephones is 22 or 24 AWG twisted pair inside telephone station cable, jacketed but not shielded. Two twisted pairs are required for an EKT and one pair for a conventional telephone. A 25pair cable is required for the ant console. The console is equipped with a male 50-pin amphenol-type connector. The PERCEPTION system requires a solid earth ground on the ground...
Page 33
consists of a single, free-standing cabinet mounted on casters for easy movement. Assembly of the DCEC consists of installing the disk drive/ringing supply subassembly (DFRA), the power supply assembly (DPSA), and the various printed circuit boards (PCBs). 5. ~stal~atio~ 5.14The DFRA subassembly, housing the Disk Drive (DFDD) and the ringing supply (DRGU), is mounted on the top shelf of the DCEC. To install the DFRA: a) b) 4 d) e) f)Loosen the 6 screws securing the rear cover of the DCEC and lift the...
Page 35
g) Secure the DFRA to the front of the DCEC using the 4 screws removed earlier.h) Replace the DCEC rear cover and tighten the 6 screws. Power Supply installation 05.21The DPSA (Figures 6 and 7) consists of a single metal chassis. Circuit breakers and LED indicators for each output, along with an AC FF switch, are located on the front panel. An AC power cord, green ground wire and two connectors are found on the rear of the unit. The two connectors are labeled J201 and J202and will receive the two mating...
Page 36
4 b) d)Remove and save the two screws located in the upper corners of the DCEC connector panel (Figure 1 I).Loosen the thumb screws that are provided for securing the connector locking the connector panel can move freely (FThe connector panel is hinged on the bottom; lower it carefully to expose the internal wiring. Locate the twe plastic connectors in- tended for the Remove the tape secur- ing their cablestothe bottom of the Dand ensure that they are positioned so as be damaged or cause damage when...
Page 37
slot switching on the DSWU PCB and supplies the system tones. DCCU (Central Control Unit)--one per system: Contains the system central processor andmain memory. Performs all system control functions. DPEU (Peripheral Equipment Interface Unit)-one per system: Performs data transmission and receiving func- tions between the central control, and all peripheral equipment, including:(Station PCBsTrunk PCBs
Page 39
2-6 (housing six circuits) is available. Only one operated in an Immediate Start, Delay Dial, DRCU per system is permitted. or Wink Start mode. Each DEMU occupies a DCOU position and, therefore, a maximum DPMU (Paging and Music-on-hold Unit)-oneof eight may be installed in a system.per system:This PC6 is required in every system, and per-DEKU (Electronic Key Telephone Unit): forms several miscellaneous functions.Interfaces eight EKTs to the system. It is also used as thrxendant console interface....
Page 40
and 600/900-ohm termination options that must be selected before they are installed: a) Ground/Loop Start selections are made in-dividually for each of the four circuits using the strapping terminals (Figure 21).shorting bar that can connect any one pair of adjacent pins. Select the desired option according to the following table. (Note; the table is printed on each DCOU PCB for ref-erence.) OPTIONSTRAP PINS TB 102-Circuit ‘ITB 202~Circuit 2 TB 302-Circuit 3 TB 402-Circuit 4NO EXTEND D-EEXTEND B-C...