Have a look at the manual Tone Commander 6002ta Analog Port Terminal Adapter User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 24 Tone Commander manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Tone Commander 6002TA User Manual7 Installation Telephone operating software must be version 01.05.xx or higher to support the 6002TA. To view the installed software version, select VERS, then S/W from the Administration Options menu (Setup → ADMIN→ VERS→ S/W). If your phones software version is lower than 01.05.xx, call Tone Commander at (800) 524-0024 to request an update. Mounting the Base ______________________ 1. Disconnect the line cord from the telephone. Power must be disconnected before installing the 6002TA. Wait 10 seconds after disconnecting power before proceeding. 2. Remove the retaining screw in the center of the base. 3. Press the top of the tall edge of the base to disengage the snap tabs, then lift the original base from the telephone body. Do not touch the expansion connector.
8Tone Commander 6002TA User Manual 4. Replace the original base with the 6002TA terminal adapter base. Plug the cable from the terminal adapter base into the expansion connector on the telephone. The polarization tab on the plug must fit into the opening on the side of the phone connector. 5. Snap the terminal adapter base onto the phone. The base may be rotated for wall mounting. 6. Replace the retaining screw (required for UL compliance). Connecting the POTS Device ______________ Connect the analog telephone device to the jack on the back of the base, using a standard 4 or 6-conductor cable. WARNING: The 6002TA is intended to connect to local analog POTS telephone devices via relatively short (less than 300 feet) inside- plant cabling. Do not connect to wiring that extends outside or between buildings, or that may be subject to electrical hazards, such as lightning or power line crosses. Do not connect to a telco network telephone line. Damage to the POTS port may occur.
Tone Commander 6002TA User Manual9 POTS Port Options The following options can be configured from the POTS Port Options menu: • Ring Control• Call Waiting • POTS Line Privacy• POTS Originating Call Appearance POTS Port Options Menu _________________ You can enter the POTS Port Options menu at any time. Press the Setup key. Select POTS. Setup SETUP MENU INSTL ADMIN USER POTS POTS PORT OPTIONS: RING PRIV CALLWT ORIG
10Tone Commander 6002TA User Manual POTS Ringing Control ___________________ You can control the audible ringing at the analog telephone device for each call appearance. Similar independent settings in the User Options menu (Setup → USER → RING → CONTROL) control ringing at the 6210/6220 telephone – refer to the 6210/6220 User Manual. Call appearances set to ALWAYS will ring immediately at the POTS port. NEVER completely disables ringing at the POTS port for the call appearance. WAIT delays ringing at the POTS port for 2 to 7 ringing cycles (6 seconds per cycle). When using a cordless phone on the analog port, select ALWAYS for primary call appearances, and NEVER for secondary or shared call appearances. You can select a WAIT option on primary call appearances when the analog phone is used as a backup answering position; set the POTS port ring delays longer than the 6210/6220 delays to ensure that calls always ring at the 6210/6220 first. Note – You cannot answer a call on the POTS port unless it is ringing (ring delays have timed out). For fax or modem applications, select ALWAYS for the fax call appearance, and NEVER for all other call appearances. Set the 6210/6220 ringing for the call appearance to NEVER; fax/modem calls will only ring at the POTS port. From the POTS Port Options menu, select RING. (Setup → POTS → RING) All multifunction keys that are programmed for call appearances or DSS will have a steady green indication. Press a lit key to view its current POTS ring control setting. The key’s indicator will alternately flash red and green. KEY01=ALWAYS RING \ ALWAYS NEVER WAIT2 WAIT3 KEY01=ALWAYS RING \ WAIT4 WAIT5 WAIT6 WAIT7
Tone Commander 6002TA User Manual11 If you want to change the setting for the selected key, select ALWAYS, NEVER, or WAIT2-WAIT7. Press the Done key to return to the POTS Port Options menu or the Setup key to exit Setup Mode. POTS Line Privacy ______________________ The Privacy setting determines whether phone and POTS calls are mutually exclusive or if they can be swapped between the handset, POTS port, and speakerphone. With Privacy off, an active call can be freely passed between the handset, speakerphone, or POTS port, by using the hookswitch or Spkr key. With Privacy on, an active call cannot be passed between the handset/speakerphone and the POTS port. Set Privacy ON if a fax or modem is connected to the POTS port, and OFF for most other applications. From the POTS Port Options menu, select PRIV. (Setup → POTS → PRIV) The current Privacy setting will be shown in the display. Select ON to enable Privacy, or OFF to disable Privacy. When finished, press the Done key to return to the POTS Port Options menu or the Setup key to exit Setup Mode. Done Done POTS LINE PRIVACY = OFF ON OFF
12Tone Commander 6002TA User Manual POTS Line Call Waiting Alert ______________ The Call Waiting option determines whether CIDCW (Calling Identity Delivery on Call Waiting) signaling, Call Waiting tone only, or no signaling will be sent to the POTS port when it is active and another inbound call arrives at the phone. For fax or modem applications, select DISABLE to prevent interruptions during a call. Your analog phone must have a caller ID display and support call waiting caller ID (CIDCW) for the CALLID function to work. Call waiting tone may still be available if provided by the ISDN network. From the POTS Port Options menu, select CALLWT. (Setup → POTS → CALLWT) The current call waiting alert setting will be shown in the display. Select one of the displayed options. CALLID – calling party ID is sent to the analog telephone device, if provided by the ISDN network. Your POTS phone must be CIDCW compatible. TONE – waiting calls are indicated by an alert tone. DISABLE – call waiting alerting is disabled. When finished, press the Done key to return to the POTS Port Options menu or the Setup key to exit Setup Mode. Done CALL WAITING=CALLER ID CALLID TONE DISABLE
Tone Commander 6002TA User Manual13 POTS Line Originating Call Appearance _____ This option selects the primary call appearance used for outgoing calls from the POTS port. If the selected call appearance is busy when placing a call, another call appearance may be used if available. For fax or modem applications, you can assign a secondary directory number (if provisioned on your line) for outgoing fax or modem calls. From the POTS Port Options menu, select ORIG. (Setup → POTS → ORIG) The current outgoing call appearance will be shown in the display, and the CA/DN key will alternately flash red and green. If you want to use a different call appearance, press another CA/DN key. Status indicators for available CA/DN keys will be green. When finished, press the Done key to return to the POTS Port Options menu or the Setup key to exit Setup Mode. Done POTS ORIGINATING CA CA1
14Tone Commander 6002TA User Manual Appendix A Warranty and Service Tone Commander Product Warranty For a period of one year from date of dealer purchase, but not to exceed 16 months from date of manufacture, Tone Commander Systems, Inc. (Tone Commander) warrants its products to be free from defects in material and workmanship under conditions of normal use and service. Tone Commander shall, at its option, repair or replace any defective product which, in its opinion, has not been misused, damaged, or improperly installed. Repair or replacement under this warranty will be performed at Tone Commanders factory. Authorization must be obtained from Tone Commander prior to returning a product for repair. Freight must be prepaid for all units returned to Tone Commander. Units repaired under warranty will be shipped UPS Ground (or equivalent), freight prepaid by Tone Commander. Products that are older than the warranty period, but less than 7 years old, or still manufactured by Tone Commander may be repaired at the factory for a flat rate charge. Repaired out-of-warranty units are warranted for 90 days from the date of repair. The repair or replacement of a product under this warranty represents the entire obligation of Tone Commander; Tone Commander shall not be liable for any special or consequential damages resulting from or caused by any defect, failure, incapacity or malfunction of any of its products. The foregoing express warranty is in lieu of all other warranties, express or implied, including but not limited to any implied warranty of merchantability, fitness, or adequacy for any purpose or use, quality, productiveness or capacity; Tone Commander, to the extent permitted by law, hereby disclaims all such other warranties.
Tone Commander 6002TA User Manual15 Appendix B Specifications Contents of Shipping Container 6002TA telephone base Manual Compatibility 6210T, 6220T, 6210U, or 6220U ISDN phones (may require firmware upgrade) May not be used with 6030X 30-Button Expansion Module or 6001TA Terminal Adapter for TAPI Capacity Supports up to 3 standard analog telephone (POTS) devices Connector Arrangement One RJ-11 6-position modular jack Battery Feed -48 V on-hook, 50 mA maximum off-hook loop current 1000 V minimum isolation from primary (ISDN) power Ringing 20 Hz, 70 Vrms nominal Maximum Load: REN=3 Maximum Recommended Loop Length 300 ft (100 M) with 24-26 AWG (inside wiring only) Transmission Characteristics 0 dB Transmit Loss, 3 dB Receive Loss ± 1 dB, 300-3000 Hz Echo Return Loss >12 dB @600 or 900 ohms Power Requirements 24 to 56.5 VDC, powered through 6210 or 6220 ISDN phone Typical 1.5 W idle, 3.5 W off-hook (including 6220T ISDN phone)
16Tone Commander 6002TA User Manual Standards Compliance FCC Part 15, Part 68 UL, cUL 60950 Section 508 §1194.23(a) non-acoustic connection point for TTYs Physical Dimensions 6.4” W x 5.7” D x 2.4” H, (replacement base for 6210/6220 ISDN phone) Weight 0.5 lb. Environmental Operating Temperature: 32° to 104° F (0° to 40° C) Storage Temperature: 32° to 122° F (0° to 50° C) Humidity: 5% to 95% non-condensing