Page 21
427-0042-00-10 Revision 130 Copyright © 2011 FLIR Systems, Inc. 21 6 CARING FOR YOUR SR-SERIES THERMAL CAMERA Your SR-series camera images through a lens that is made from material that is transparent to long-wave infrared energy. This lens is designed for the harsh outdoor environment and has a coating for durability, but may require occasional cleaning. FLIR Systems Inc. suggests that you clean the lens when image quality degradation is noticed or excessive contaminant...
Page 22
427-0042-00-10 Revision 130 Copyright © 2011 FLIR Systems, Inc. 22 7 TROUBLESHOOTING PROBLEMS Video not displayed on monitor If the camera will not produce an image, check the video connection at the camera and at your display. If the connectors appear to be properly engaged but the camera still does not produce an image, ensure that power has been properly applied to the camera and the fuse is not blown. Cycle power to the camera and listen for the FFC shutter to click....
Page 23
427-0042-00-10 Revision 130 Copyright © 2011 FLIR Systems, Inc. 23 Performance varies with time of day You may observe differences in the way the camera performs at different times of the day, due to the diurnal cycle of the sun. Recall that the camera produces an image based on temperature differences. At certain times of the day, such as just before dawn, the objects in the image scene may all be roughly the same temperature, compared to other times of the day. Compare...
Page 24
427-0042-00-10 Revision 130 Copyright © 2011 FLIR Systems, Inc. 24 8 SR-SERIES CAMERA SPECIFICATIONS Feature Specification Input Power See below Dimensions, Weight See below Sensor type Uncooled Microbolometer Spectral range 7.5 to 13μm Focal Length SR-304, SR-606 100 mm SR-309, SR-612 50 mm SR-313, SR-618 35 mm SR-625 25 mm SR-324, SR-112...
Page 25
427-0042-00-10 Revision 130 Copyright © 2011 FLIR Systems, Inc. 25 Input Power The electrical interface board provides a screw-terminal jack for receiving 14 to 28 gauge tinned leads for input power. The following table describes the input power requirements at 25o C. Peak ratings can occur in cold environments when the heater circuits on. Parameter Requirement True PowerApparent Power Comment AC Input Voltage 18 to 27 VAC Voltage as measured at the input to...
Page 26
427-0042-00-10 Revision 130 Copyright © 2011 FLIR Systems, Inc. 26 8.1 SR-Series Camera Dimensions Figure 8-1: Camera Side View Figure 8-2: Camera Rear View Dimension All cameras except SR-304 & SR-606 SR-304 & SR-606 Length 10.5” (26.7) 15” (38.14) Width 5.0” (12.7) 5.0” (12.7) Height 5.7” (14.4) 5.68” (14.4) Weight 4.6 lb (2.1 kg) 6.5 lb (2.9 kg) Note: Values in parentheses are in centimeters, all others in inches. Length Height Width
Page 27
427-0042-00-10 Revision 130 Copyright © 2011 FLIR Systems, Inc. 27 Figure 8-3: Enclosure Mounting Foot 9 REFERENCES FLIR Standard Resolution Product Specification Document Number: 427-0014-00-09 FLIR Tau GUI Users Manual Document Number TAU-0035-00-10 Pelco EH2500 Series Enclosure Product Specification NTSC EIA-170 PAL CCIR 624 MIL-STD-810E Environmental Testing MIL-STD-188-124B, Grounding, Bonding and Shielding IEC 60529 Degrees of protection provided by...
Page 28
427-0042-00-10 Revision 130 Copyright © 2011 FLIR Systems, Inc. 28 Support If you have questions that are not covered in this manual, or need more information, contact your local FLIR service representative or, 1 (877) 773-3547 inside the US. In the US, you can reach FLIR Customer Support at (888) 747-FLIR (747-3547).