Page 61
427-0073-12-12 Version 110 June 2014 3-21 3Advanced Configuration Alarm Actions: Just as there can be many sources of alarms, there are also a variety of responses or actions to these alarms. Some of the alarm actions are only used with pan/tilt cameras. Actions such as Point, Load ScanList, Go To Preset, and Engage Radar Track would only be used with a pan/tilt camera and are not used with the FC-Series fixed camera. For the FC-Series, typically a rule will be configured to Send a...
Page 62
427-0073-12-12 Version 110 June 2014 3-22 3Advanced Configuration Video Analytics Alarm to Email: Shown at the right is an example of an alarm rule that causes an email notification (including a snapshot image) to be sent when a motion alarm occurs in VA Area 0 or 1 (refer to Creating Motion Detection Areas, pg. 3-5). The Alarm Source Device Type is set to Video Analytics with Alarm Id 0,1 corresponding to VA Areas 0 and 1. The Action, Send Notification, references the Default Notification List...
Page 63
427-0073-12-12 Version 110 June 2014 3-23 3Advanced Configuration 3.2.2Files Menu The admin actions for transferring files are accessed through the Files menu on the left side of the page. Selected actions from the Configuration and Media Browser are described below. Use the Configuration page to see the Nexus Configuration File, perform Backup & Recovery of local files (on the camera), and perform Upload & Download of configuration files to another computer for backup, or to install a new...
Page 64
427-0073-12-12 Version 110 June 2014 3-24 3Advanced Configuration Media Browser: The Media Browser page shows all of the images captured by the camera as a result of an alarm action. The image files can be downloaded to another computer for backup. After selecting a file, the file will appear in the Preview window. The file name contains the year, month, day, 24 hour clock time, and the sensor that captured the image. In this case IR0 is the only sensor. Select Download to download the selected...
Page 65
427-0073-12-12 Version 110 June 2014 3-25 3Advanced Configuration 3.2.3 Product Info Menu The admin functions accessed through the Product Info menu on the left side of the page are shown. Selected actions from the Config File page are described below. Use the Config File page to change the Friendly Name which appears in FSM by default. You can also include the Friendly Name on the video feeds and adjust its appearance on the OSD page (refer to On Screen Display (OSD), pg. 3-18). Click on the...
Page 66
427-0073-12-12 Version 110 June 2014 3-26 3Advanced Configuration 3.3 Restoring the Factory Settings The camera comes configured from the factory with a default IP address (192.168.250.116), the login passwords (user, expert, fliradmin), and all of the other configuration parameters (stored in a file called server.ini). In some cases, it may be necessary to restore the network settings of the camera to the original factory settings. If necessary, the camera IP address can be restored to this factory...