Tascam FX D1000 Instrallation Manual
Have a look at the manual Tascam FX D1000 Instrallation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 511 Tascam manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

. . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .INSTALLATION INSTRUCTIONS SOFTWARE LEVEL: Your TM-D1000 MUST be at software level 1.18 or higherfor this option to work properly. To check your software revision level: Power up the TM-D1000. 1) Press SHIFT and MEMO. The display should read: 2) Push DATA ENTRY button downwards 4 times until “SYSTEM” appears. 3) Rotate “DATA ENTRY(PUSH)” knob clockwise until the version appears. If the software version is LESS than 1.18, the internal programmable logic device (PLD) must be updated. Included in this FX-D1000 package is a new PLD with the most current software available at the time of manufacturing. Instructions on how to change the PLD are included in this document. If the software in your console is already version 1.18 or higher, please return the provided PLD in the pre- addressed envelope included with your FX-D1000. This will allow us to help other customers and keep the costs of these options to a minimum. _____________________________________________________________________________ CAUTIONTo avoid damaging any of the electronic components, by means of static electricity, please wear the included grounding wrist strap before starting the installations. STEP 1: Removing the bottom panel: Disconnect the power cable and any audio cables. Turn the unit overon a padded surface and remove the screws as shown below.TASCAM TEAC Professional Division 7733 Telegraph Road Montebello, CA 90640 Phone (323) 726-0303 Fax (323) 727-7632For Details, Contact: Operation Support Group TEAC America, Inc. (323) 726-0303MODEL: FX-D1000InstallationInstructionsMODELS AFFECTED: TM-D1000Option Monitor >Mode VOption Monitor >System VTM-D1000 < Ver1.18Take care not to use a long screw here. Only Use the 3x5 screw .6 pcs M3x8 for the side 4 pcs M3x8 for the corners of the rear panel

FX-D1000 10/08/99 Page 2 of 6TASCAM TEAC Professional Division 7733 Telegraph Road Montebello, CA 90640 Phone (323) 726-0303 Fax (323) 727-7632INSTALLATION INSTRUCTIONS IMPORTANT WARNING!!! Special care should be taken when re-installing the bottom coverscrews. As the diagram above shows, the screws MUST be reinstalled in the same position as they wereremoved. Note the location of the special 5mm screw! If an 8mm screw is installed where the 5mm screwwas removed, the extra penetration by the 8mm screw may short circuit the electronics.STEP 2: Removing and positioning the bottom panel: Remove the rack-mounting flanges if installed. Afterremoving all the screws identified in the above illustration, remove the bottom cover of your TM- D1000. It may be necessary to use a soft prying device like a wooden stick to loosen the bottom panel from the top panel. If your TM-D1000 has software revision 1.18 or greater, skip to step 6! If you need to upgrade continue on to step 3. UPGRADING THE TM-D1000 INTERNAL PLD TO THE LATEST SOFTWARE REVISION LEVEL:STEP 3: Removing U17, Main PLD: Locate U17 on the Main PCB as shown in the diagram (Figure 1.2).The PLD is held in place with a rectangular black plastic locking device. Slide the locking device down or toward you. Remove it by lifting straight up from the main PCB. Remove the PLD and place itPrecaution: To avoid damage to the wires linking Main and Power Supply PCB Assy, place the bottom panel beside the main unit as indicated below.U17FIGURE 1.1FIGURE 1.2

FX-D1000 10/08/99 Page 3 of 6TASCAM TEAC Professional Division 7733 Telegraph Road Montebello, CA 90640 Phone (323) 726-0303 Fax (323) 727-7632INSTALLATION INSTRUCTIONS DetachAttachinto the plastic case supplied with the new PLD. Place it into the postage paid self-addressed envelope provided and return to TASCAM. Thank you! STEP 4: Installing the new PLD: CAUTION: The PLD is sensitive to static discharges and may bedamaged if improperly handled. It is highly recommended that the installer be well grounded before handling the device: Note the orientation of the small dot on the PLD. It must be installed with this dot in the lower right corner as shown in the diagram to the right. On the main PCB, the white silk-screened outline of U17 also shows a small white dot in the lower right corner. These two dots must line up. After aligning the locator dots, lay the PLD into position. Secure the PLD by placing the rectangular black plastic locking device over the PLD. After it is set in place, sliding the locking device upwards will lock it into position. (See the diagram above and to the right.) STEP 5: The software has now been upgraded in your TASCAM TM-D1000.INSTALLING THE FX-D1000:STEP 6:Locate the three plastic standoffs in the package with the FX-D1000 effects module. Using thediagram (Figure 1.3), locate the position for these standoffs on the Main PCB and install one standoff in each of the three holes. IMPORTANTRemove the protective spacer that is installed in connector CN1 before proceeding.

FX-D1000 10/08/99 Page 4 of 6TASCAM TEAC Professional Division 7733 Telegraph Road Montebello, CA 90640 Phone (323) 726-0303 Fax (323) 727-7632INSTALLATION INSTRUCTIONS STEP 7:Remove the FX-D1000 from its anti-static wrapping. Holding the FX-D1000 by its edges, orientit as shown in Figure 1.3. The component side of the board should be on the bottom. STEP 8:The connector on the FX-D1000 should be inserted into connector CN5 on the main PCB. Fit thethree retaining studs you installed into the Main PCB into the corresponding holes on the FX- D1000. After insuring the pins on the connector and the retaining studs are aligned properly, press the FX-D1000 firmly into place. STEP 9:Reassembling the unit: Reversing the procedure used in STEP 2 above, Reposition the rearcover over the top cover on your TM-D1000. Align and press the two halves of the cover together until they securely mate. STEP 10: Re-install all the screws.IT IS IMPORTANT THAT THE SCREWS ARE INSTALLED IN THE SAME LOCATION FROM WHERE THEY WERE REMOVED! Failure to do so may cause electrical damage to the TM-D1000! If the TM-D1000 was rack-mounted, replace the rack-mounting flanges, and screw them into position, otherwise simply replace the 10 screws, which fastened the side panels. If an armrest was installed, replace it with the three screws removed earlier.FIGURE 1.3Orient the FX-D1000 with the components facing the main PCB.Locations for the plastic standoffsFX-D10000

FX-D1000 10/08/99 Page 5 of 6TASCAM TEAC Professional Division 7733 Telegraph Road Montebello, CA 90640 Phone (323) 726-0303 Fax (323) 727-7632INSTALLATION INSTRUCTIONS STEP 11: Checking software operation: Turn your TM-D1000 over so it is right side up and resting onits feet. Reconnect the power cord. Power up the TM-D1000 Confirm that the TM-D1000 recognizes the FX-D1000 with the following steps: Press the SHIFT and PARAM SEL. buttons. The display should show: Option MODETurn the DATA ENTRY (PUSH) knob, select Effect then press ENTER. Effect Effect Pattern ?Press ENTER, turn the DATA ENTRY(PUSH) knob. As you rotate the knob, 20 different effects patterns should appear in the display beginning with the display shown below on the left and ending with the display shown below on the right. Effect Pattern Ch Dynamics[8ch] ?>Effect Pattern Aux1-2:Eff2 Aux3-4:Eff1?STEP 12: If you confirmed that there are now 20 Effects Patterns” available through the step above, yourFX-D1000 has been installed and is operating correctly. If you do NOT get 20 patterns, you will need to contact TASCAM operational support at (323) 726-0303 extension 617 for assistance. The table on the next page shows all the effects patterns available. The first table represents the “Effect Pattern Menu” prior to the installation (6 patterns). The second table represents the new“Effects Pattern Menu” following the installation of your new FX-D1000 (20 patterns).

FX-D1000 10/08/99 Page 6 of 6TASCAM TEAC Professional Division 7733 Telegraph Road Montebello, CA 90640 Phone (323) 726-0303 Fax (323) 727-7632INSTALLATION INSTRUCTIONS TABLE FOR OPTION/EFFECT/EFFECT PATTERN LCD1st line2nd lineDescriptionSystemE f f e c t _ P a t t e r n _ _ _ _ _ _ _ _ _ _ C h _ D y n a m i c s _ _ _ _ _ _ _ _ _ _ _ _ ? Effect Pattern1WithoutL-R:Eff1_ _ _ _ _ Aux1-2:Eff2_?Effect Pattern2FX-D1000Aux1-2:Eff[Cascade1-2]_?Effect Pattern3Aux1-2:Eff[Cascade2-1]_?Effect Pattern4Aux1-2:Eff[_ _ _ Para_ _ _ ]_?Effect Pattern5Aux1-2:Eff2_Aux3-4:Eff1?Effect Pattern6System withE f f e c t _ P a t t e r n _ _ _ _ _ _ _ _ _ _ C h _ D y m a n i c s [ 8 c h ] _ _ _ _ _ _ _ _ Effect Pattern1WithC h _ D y n a m i c s + A u x 1 - 2 + L - R _ ? Effect Pattern2FX-D1000C h _ D y n m c s + A u x 1 - 2 [ C s c d ] _ ? Effect Pattern3C h _ D y n m c s + A u x 1 - 2 [ P a r a ] _ ? Effect Pattern4C h _ D y n m c s + A u x 1 - 2 + A u x 3 - 4 ? Effect Pattern5A u x 1 - 2 + A u x 3 , 4 [ M o n o ] + L - R ? Effect Pattern6A x 1 - 2 [ C s c d ] + A x 3 , 4 [ M o n o ] ? Effect Pattern7A u x 1 - 2 [ C s c d ] + L - R [ C s c d ] _ ? Effect Pattern8A x 1 - 2 [ C s c d ] + A x 3 - 4 [ C s c d ] ? Effect Pattern9A x 1 - 2 [ C s c d ] + A x 3 - 4 [ P a r a ] ? Effect Pattern10A x 1 - 2 [ C s c d ] + A u x 3 - 4 + L - R _ ? Effect Pattern11A u x 1 - 2 [ C s c d 3 ] + A u x 3 - 4 _ _ _ ? Effect Pattern12A u x 1 - 2 [ C s c d 3 ] + L - R _ _ _ _ _ _ Effect Pattern13A u x 1 - 2 + L - R [ C s c d 3 ] _ _ _ _ _ _ ? Effect Pattern14A x 1 - 2 [ P a r a ] + A x 3 - 4 [ P a r a ] ? Effect Pattern15L-R:Eff1___Aux1-2:Eff2_?Effect Pattern16Aux1-2:Eff[Cascade1-2]_?Effect Pattern17Aux1-2:Eff[Cascade2-1]_?Effect Pattern18Aux1-2:Eff[_ _ _ Para_ _ _ ]_?Effect Pattern19Aux1-2:Eff2_Aux3-4:Eff1?Effect Pattern20