Home > Sunbeam > Air Conditioner > Sunbeam Ky-25 Y Manual

Sunbeam Ky-25 Y Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Sunbeam Ky-25 Y Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 18 Sunbeam manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							4.1 PORTABLE AIR CONDITIONER INSTALLATION
    SECTION 4                INSTALLATION INSTRUCTIONS
    Figure 8 • Find a proper place for the portable air conditioner. 
    Leave at least 20” (50.8cm) space around the unit (Fig. 8).
    4.2 INSTALLING THE DUCTS IN A WINDOW/SLIDING DOOR
    A)  Pull out both ends of the hot air exhaust ducts for approximately 6”/15.24cm.
    B)  Screw the exhaust ducts clockwise with one end to the terminal end of the back of the unit and
    the other end to the window kit adapter.
    C)  Mount the terminal end of the exhaust duct to the back of the unit.
    D)  Open window or sliding door for approximately 5”/12.7cm.
    E)  Adjust the length of the window kit to the same length of the window or the sliding door. Use
    all of the panels if necessary. Cut the window piece as needed to fit the length of your window
    or sliding door. Make sure that the hole on the main piece is not covered by other pieces.
    F)  Place the window kit in the window or sliding door. Close the window or door as far as it goes.
    G)  Adjust the length of exhaust duct and affix the window kit adapter onto the holes on the
    window kit.
    NOTE:When using the window kit on a window or sliding door it will cause the window or sliding 
    door to not be properly closed and/or locked. Additional security measurements should 
    be taken.
    10
    When you use the unit as an air conditioner or a
    dehumidifier, the hot air must be exhausted out of
    the room to complete the air exchange of the
    condenser. When the unit is operating on fan, no
    outdoor air exchange takes place. You do not need
    to hookup the window kits and hot air exhaust
    ducts when you use the unit as a fan.
    Figure 9 
    						
    							SECTION 4                INSTALLATION INSTRUCTIONS
    11
    4.3 INSTALLING THE DUCTS IN THE WALL
    Figure 11 A) You do not need to use window kit adapter. Mount one end of the exhaust duct into a hole
    of 5.6”/14.22cm in diameter in the wall; attach the other end to the back of the unit (same 
    as above).
    B)  Use the exhaust outlet wall covers to cover the holes in the wall when the unit is not in use.
    NOTE:
    Mounting the exhaust pipe
    • The supplied exhaust hose can extend from 5.75”
    to 63” / 40cm to 160cm for mounting. It is
    recommended that you use the shortest possible
    length of hose.
    •  Take care to prevent any kind of bend in the
    middle of the exhaust hose, as this will trap hot
    exhaust air, which will radiate back into the
    room and affect the cooling function of the unit
    (Fig. 10).
    The length of the exhaust pipe is specially designed
    according to the specification of this product. Do not
    replace or extend it with your own hose as this could
    cause the unit to malfunction (Fig. 11).
    C)  After installing the ducts, plug in the unit and turn the unit on.
    Figure 10
    MANUFACTURER’S RECOMMENDATION.
    BEFORE UNDERTAKING ANY INSTALLATION OF DUCTS INTO WALL, WE
    RECOMMEND THAT YOU CONSULT A KNOWLEDGABLE PROFESSIONAL.
    CAUTION
    WARNING 
    						
    							SECTION 5  OPERATING YOUR PORTABLE AIR CONDITIONER
    5.1  CONTROL PANEL AND OPERATING FUNCTIONS
    If the unit is turned off during operation please wait at least
    three minutes before starting it again.
    Figure 12
    1)         On/Off Button: Use to Start or Stop the unit.
    2)         Operation Mode Selection Button: Use to select the operation mode: 
    AutoMode, Fan-OnlyMode, Soft-DryMode, and CoolingMode. 
    3)         Fan Speed Selection Button: Use to Select the fan speed: 
    Highspeed or Lowspeed.
    4)         “Up”  or          “Down”: Temperature or Time Changing Button:  Use these two buttons to 
    set to your desired temperature. The temperature unit can be on Fahrenheit or Centigrade. Press the 
    ON/OFF Button for more than 20 seconds, then release. The temperature unit will be changed from 
    Fahrenheit to Centigrade or vice versa. During the timer set-up, these buttons are also used to 
    change the time.  
    5)         Timer Setting or Cancel Button:Use to set or cancel TIMER-ON or TIMER-OFF timer. When 
    the unit is on, the unit can be set with Timer-OFF. When the unit is off, the unit can be set with 
    Timer-ON.
    12
    WARNING 
    						
    							SECTION 5  OPERATING YOUR PORTABLE AIR CONDITIONER
    13
    5.1  CONTROL PANEL AND OPERATING FUNCTIONS CONT’D
    HOW TO SET:
    When the unit is ON, press the        Timer button, “      “ will flash in Timer Set Display Windowand the
    Timer Indicatorwill be on in the control panel.  Pressing the         “Up” or the         “Down” button will
    change the time accordingly; the flashing digits will change accordingly, until your desired delay time appears.
    Your desired time delay will flash for ten (10) seconds. After these ten (10) seconds the digits will change to
    display your selected time delay. Time displayed will decrease in ten (6) minute increments.
    When the unit is OFF, if it hasn’t been set on Time Delay, press the        Timer button.  The unit enters Timer
    Program.Also, the  “      “ will flash in Timer Set Display Windowand the Timer Indicator will be on in the
    control panel. Press the         “Up” or the         “Down” button to set to your desired time. When you are
    setting the time, the other settings like Operation Mode, Fan Mode, or Set Temperature, will also display.
    Ten (10) seconds later, these modes will disappear but be remembered by the Main Controller.
    HOW TO CANCEL:  
    When the unit is set with the TIMER-OFF or the TIMER-ON procedures, press the         Timer buttonto check
    the Timer set time, then press within ten (10) seconds to cancel the timer setting.
    5.2  LCD DISPLAY PANEL
    Auto mode
    Soft-dry mode
    Cooling mode
    Fan-only modeFahrenheit mode
    Centigrade mode
    Figure 13 
    						
    							SECTION 5  OPERATING YOUR PORTABLE AIR CONDITIONER
    5.3  OPERATING REMOTE CONTROL (MODEL KY-25Y ONLY)
    14
    The functionality of the six (6) buttons on the Remote
    Control are identical to the functionality of the buttons
    on the Control Panel. Icons for certain buttons may differ
    slightly. The Remote Control uses the lithium batteries,
    Model: CR2025 (Included). Install the batteries before
    using the Remote Control.
    You can operate the unit either on the Control Panel or
    with the Remote Control.
    COOLING OPERATION:
    1)  Plug the Power Cord into the power outlet.
    2)  Turn on the unit by pressing the      ON/OFF Button
    on the control panel or the remote control.
    3) Press the Mode Button on the remote control      or
    the control panel      until the      symbol appears on
    the display.
    4)  Set the room temperature to your desired room
    temperature with the temperature ranges from 64°F-
    90°F/18°C-32°C. Recommended temperatures are 80°F-
    84°F/27°C-29°C.
    5)   Select the fan speed by pressing the Fan Buttonon
    either the remote control      or the control panel    .
    SOFT-DRY OPERATION:
    1) Plug the Power Cord into the power outlet.
    2) Turn on the unit by pressing the      ON/OFF Buttonon the control panel or the remote control.
    3) Press the Mode Button on the remote control      or the control panel      until the      symbol
    appears on the display.
    4) Set the room temperature to an appropriate temperature.
    5)  Keep the windows and the doors closed to aid the effectiveness of the unit in removing the
    moisture from the room.
    NOTE:  The unit will not perform its dehumidifying function when the room temperature is lower
    than 64°F/18°C. Soft-Dry Modeis a very gentle cooling operation consisting primarily of
    dehumidifying. It will not lower the room temperature very much. The indoor unit Fan
    always runs at Low speed.
    Figure 14 
    						
    							SECTION 5  OPERATING YOUR PORTABLE AIR CONDITIONER
    15
    5.3  OPERATING REMOTE CONTROL (MODEL KY-25Y ONLY) CONT’D...
    FAN-ONLY OPERATION:
    1)  Plug the Power Cord into the power outlet.
    2)  Turn on the unit by pressing the      ON/OFF Buttonon the control panel or the remote control.
    3) Press the Mode Button on the remote control      or the control panel      until the      symbol
    appears on the display.
    4)  Select the fan speed by pressing the Fan Buttonon either the remote control      or the control
    panel     .
    When inFan-Only Mode, the exhaust duct is not needed, and the compressor and condenser side fan
    motor will not work. Temperature setting has no meaning and no controlling action. 
    AUTO OPERATION:
    1) Plug the Power Cord into the power outlet.
    2)  Turn on the unit by pressing the      ON/OFF Buttonon the control panel or the remote control.
    3) Press the Mode Button on the remote control      or the control panel      until the      symbol
    appears on the display.
    4)  Set the room temperature to your desired room temperature with        “Down” or         “Up”
    Temperature Changing Buttons.
    5)  Select the fan speed by using the FAN Speed button on either the remote control      or the
    control panel     . 
    When in the AUTOmode, the unit will be in Fan-Only Mode when the room temperature is below
    81°F/27°C.  It will operate in Cooling Mode when the room temperature is above 81°F/27°C. 
    TIMER-ON PROGRAM SETTING:
    How to set:
    When the unit is off, you can set the timer to let the unit automatically turn on.
    1) Press the Timer Set Buttonon the control panel      or on the remote control     . The “      “ will
    flash in Timer Set Display Window, and the Timer Indicator, on the control panel, will turn on. The
    other mode settings like Operation Mode, Fan Mode, Set Temperature Mode, will also be
    displayed, allowing you to change or set them as well.
    2) Press the       “Down” button or the      “Up” button to change the Timer delay time to your 
    desired time.
    3 After a ten (10) second delay (not pressing on any buttons), the digit will change to display, and
    the other setting modes will disappear.  Now the Timer Setting Process is complete.  Once some
    time has passed, the digits will decrease in 6 minute increments.
    When the digits decrease to ZERO and disappear, the unit will start to run automatically
    according to your setting.
    How to cancel:
    When the unit is set with TIMER-ON while it’s off, press the Timer Buttonon the control panel      or
    on the remote control       to check the Timer setting and the Time digits will flash. Press the
    TIMERbutton again; this will cancel the timed setting. The Timer Indicator on the control panel will
    then turn off. 
    						
    							SECTION 5  OPERATING YOUR PORTABLE AIR CONDITIONER
    16
    TIMER-OFF PROGRAM SETTING:
    How to set:
    When the unit is on, after being set with the TIMER-OFF, the unit will stop after your set delay time.
    1) Press the Timer Buttonon the control panel      or on the remote control     .  Now the TIMER
    INDICATOR “      “ will flash in the Timer Set Display Window, and the Timer Indicator on the
    control panel will be on.
    2)  Press the       “Down” button or the      “Up” button to change the delay time to your desired time.
    3)  After a 10 second delay (not pressing on any buttons), the digits will change to display.  The Timer
    Setting Process is complete.  Once some time has passed, the digits will decrease in 10 minute
    increments.
    How to cancel:
    When the unit is set with TIMER-OFF, while the unit is on, first press Timer Buttonon the control
    panel      or on the remote control      to check the Timer setting and the Time digits will flash. Press
    the TIMER buttonagain and the Timer Setting will be cancelled. The Timer Indicator on the control
    panel will then turn off.
    WATER FULL INDICATION:
    Under normal temperatures, water will evaporate without the need to drain it from the unit.
    The WATER FULLindicator light will turn on during days of extreme humidity, when in Cooling Mode
    or Soft-Dry Mode. When the WATER FULLindicator light turns on, it means that the water reservoir is
    full. The compressor will stop working, but both of the two fan motors will continue working. The unit
    will drain excess water once a Drain Hose or Garden Hose is connected to it. When the WATER FULL
    indicator light disappears, the compressor will start to work again.
    5.3  OPERATING REMOTE CONTROL (MODEL KY-25Y ONLY) CONT’D...
    5.4  WATER FULL INDICATION AND DRAINING
    DRAINING:
    Only in extreme humidity
    1)  To add a Drain Hose or Garden Hose you must first stop the unit by turning it OFF. You must then
    unscrew the Drain Cap on the Pump Drain before inserting the white Drain Hose (5’3”/1.61m)
    provided with your unit. (Attention: there may be some water behind the Drain Cap. Have a bowl
    or receptacle ready to catch any runoff). 
    After connecting the Drain Hose to the inner spout (Fig.15) of the Pump Drain, ensure that the
    other end is placed in a bucket or receptacle for gathering the excess water. Check the water level
    in the receptacle to avoid any possibilities of leaking. 
    Instead of the Drain Hose provided with your unit, you may also use a Garden Hose (in cases where
    you require a distance longer than that provided by the Drain Hose). In this case screw the female
    end of a Garden Hose to the outer threaded spout of the Pump Drain (Fig.16). After connecting the
    Garden Hose, place the outer end outside of the house or in a convenient area where the excess
    water can be safely expelled. 
    2) Now, turn the unit ON and back to its previous setting (either COOLING or SOFT-DRY mode).  The
    Pump Drain will begin to pump water out of the unit. (If using a water bucket, please check the
    expelled water level to ensure that it does not over flow.)  Once the WATER FULL light indicator
    turns off … the DRAIN cycle is complete.  At this point, turn OFF the unit, remove the Drain Hose or
    Garden Hose and then turn the unit back ON and to its previous setting (COOLING or SOFT-DRY
    mode). 
    						
    							SECTION 5  OPERATING YOUR PORTABLE AIR CONDITIONER
    17
    1
    2
    3
    1. Pump Drain
    2. Drain Hose
    3. Water bucket
    Figure 15Figure 16
    5.4  WATER FULL INDICATION AND DRAINING CONT’D...
    NOTE:The cooling efficiency of your unit will be affected if the Drain Hose or the Garden Hose is 
    always attached to it. The Drain Hose or Garden Hose must be used only when the WATER 
    FULL indicator is on.
    MAKE SURE THAT THE DRAIN CAP IS REINSTALLED PROPERLY TO PREVENT LEAKING. 
    						
    							6.2 CLEANING OR REPLACING THE AIR FILTER
    If the air filter is blocked with a lot of dust, the volume of airflow will be reduced and the cooling
    effect will be lower.  It is recommended to clean the filter once every two weeks or as needed.
    A)  Pull out the filter from the filter compartment in front of the unit.
    B) Wash the air filter by immersing it gently into warm (about 104°F/40°C) water with a gentle
    detergent.  Rinse the filter and dry it thoroughly in a shaded place.
    C)  Place the filter back into the filter compartment after it is thoroughly dried.
    D)  If the filter is torn or unusable, order a new filter by calling the Sunbeam Customer Service
    department at 1-877-383-6399 (8:30am-5:30pm E.S.T.).
    SECTION 6   CARING FOR YOUR PORTABLE AIR CONDITIONER
    18
    6.3 EXTERNAL PLASTIC PARTS
    A)  Keep the unit from being exposed directly to the sun.
    B)  Clean the surface with a damp cloth. 
    C)  For the Stainless Steel finished models, a good quality stainless steel cleaner should be used.
    6.4 STORAGE AT THE END OF THE COOLING SEASON
    A)  On a warm day, turn the unit on in the FAN-ONLY
    Mode for a couple of hours so that the inside can dry
    out completely.
    B)  Turn off the unit and unplug the unit.
    C)  Empty the residual condensated water by unplugging
    the LOWER WATER DRAINAGE CAP at the back
    towards the bottom of the unit. 
    After connecting the
    12’/3.65m white Drain Hose, ensure that the other end is
    in a bucket or receptacle for gathering the water.
    D)  Discharge the Hot air duct and shorten it and pack it
    in the box.
    E)   Clean the filter and dry it completely before fitting
    back in place.
    F)  Cover the appliance to protect it from dust. It is
    recommended that the unit be put back into its
    original box and package.
    G)  The unit should be stored in a cool dry place.  Do not
    stack heavy objects on the top of the unit.
    Figure 17
    Lower drain port
    6.1 MAINTENANCE
    WARNING
    •  Make sure the power supply is switched off and the plug is pulled out of the power outlet
    before performing any maintenance activities.
    •  Do not immerse the unit in water or other liquids.
    •  Do not pour liquids into the unit.
    •   Take special precaution to avoid the sharp cutting edges of some parts.
    •  Do not use any kind of chemical solvents to clean the unit, as they may deform the
    unit cabinet. 
    						
    							SECTION 7                            TROUBLESHOOTING
    19
    You can solve many common portable air conditioner problems easily, saving you the cost of a
    service call. Try the suggestions below to see if you can solve your problem without outside help.
    Check if... Then...
    Wait until local power is restored. The local power 
    has failed.
    The plug is loose.Firmly insert the plug into the wall socket.
    Drain out the water (see page 16).
    Set the proper time. The power fuse 
    is burned.
    Replace the fuse. Make sure the portable air conditioner is plugged
    into an exclusive properly grounded outlet as described in the
    Installation Instructions.
    The water tank is full.
    LCDI plug has tripped.
    Press the RESET button on the LCDI plug.
    The time is set properly.
    Check if... Then...
    Open the air inlet and outlet. The air inlet or 
    outlet is closed.
    There is a heat source 
    in the room.Move the heat source away.
    Set the cooling temperature at a proper level. The air filter is dirty.
    Clean the air filter, referring to Cleaning the Air Filter section.
    The cooling temperature
    is set properly.
    7.1   PORTABLE AIR CONDITIONER DOES NOT WORK AT ALL
    7.2   LOW COOLING EFFICIENCY
    The indoor fan is 
    set at a low speed.Set the indoor fan speed higher.
    Water-Full Indicator 
    is displayed.Empty the water inside the unit (see page 16). Wait 1 hour to let
    the condenser side fan blow out the water. 
    						
    All Sunbeam manuals Comments (0)