Steinberg Cubase 8 Manual
Here you can view all the pages of manual Steinberg Cubase 8 Manual. The Steinberg manuals for Music Production System are available online for free. You can easily download all the documents as PDF.
Page 311
MixConsole VCA Faders (Cubase Pro only) 311 Assigning VCA Faders to Link Groups You can link channels and assign VCA faders to control them. PREREQUISITE You have selected channels. PROCEDURE 1. Click Link on the MixConsole toolbar. The Link Group Settings dialog opens. 2. Click in the Name field to enter a name for the link group. 3. Activate Use VCA Fader. The Volume parameter is automatically deactivated. 4. Specify if you want to create a new VCA fader or select an existing VCA fader from the...
Page 312
MixConsole VCA Faders (Cubase Pro only) 312 3. Click OK. 4. Specify if the channels in the link group keep the combined automation. RESULT The VCA fader is removed from the link group and is deleted from the list of channels. NOTE You can keep the VCA fader in the fader section. In this case, open the VCA fader pop-up menu, select VCA Fader Controls Link Group: , and select None. This removes only the VCA fader assignment. Nested VCA Faders VCA faders can control other VCA faders. If you use several...
Page 313
MixConsole VCA Faders (Cubase Pro only) 313 VCA Fader Automation VCA fader automation influences the automation of link groups. When you create VCA faders, their tracks in the Project window contain the static value line that is default for all automation tracks and that turns into an automation curve once you start writing automation. When you write automation for a VCA fader of a link group, it affects the volume automation of the linked channels. This has different effects: • If a linked channel...
Page 314
MixConsole Metering (Cubase Pro only) 314 The lighter static value line displays the VCA fader automation that has not been written yet. VCA fader track automation The VCA fader track has a different automation curve that affects the automation of the audio track. Original audio track automation and combined automation of VCA fader and audio track The underlying darker automation curve displays the original automation of the audio track. The overlaying lighter automation curve displays the combined...
Page 315
MixConsole Metering (Cubase Pro only) 315 Displaying Meters PROCEDURE 1. In the MixConsole, click the Set up Window Layout button on the toolbar and activate Control Room/Meter. 2. Click the Meter tab at the top of the Control Room/Meter section. By default, the master meter is displayed. Master Meter The master meter is a multi-channel true peak meter. 1)Control Room view Activates the Control Room section in the MixConsole. 2)Scales Lets you select a scale according to different broadcast standards...
Page 316
MixConsole Metering (Cubase Pro only) 316 5)AES17 standard Activates the AES17 standard that adds an offset of 3 dB to the RMS value. 6)RMS/Peak meter Shows the RMS and peak hold values as blue lines and the peak values as gray lines. The following parameters are available: RMS Max Shows the maximum RMS value. Peak Max Shows the maximum peak value. RELATED LINKS Control Room (Cubase Pro only) on page 352 Loudness Meter The loudness meter complies to the loudness recommendation R 128 of the European...
Page 317
MixConsole Metering (Cubase Pro only) 317 1)Control Room view Activates the Control Room section in the MixConsole. 2)Loudness meter Shows the Momentary Max value as a green triangle in the left meter scale and the Integrated value as a gray triangle in the right meter scale. 3)Measure Loudness Activates the loudness measurement. 4)Switch between LUFS and LU Switches the meter scale between LUFS (absolute values) and LU (relative values). 5)Configure Loudness Settings Lets you specify a threshold value...
Page 318
MixConsole Input Levels 318 The following parameters are available: Momentary Max Shows the maximum loudness measured over a duration of 400 ms. Short Term Shows the loudness measured over a duration of 3 ms. Integrated Shows the average loudness measured from start to stop. The period of measurement is shown in the Time display. The recommended value for the integrated loudness is -23 LUFS. This absolute value is the reference point for the relative LU scale where -23 LUFS equals 0 LU. Range Shows...
Page 319
MixConsole Copying and Moving Rack and Channel Settings 319 3. Play back the audio and check the level meter for the input channel. The signal should be as loud as possible without exceeding 0 dB that is the clipping indicator for the input bus should not light up. 4. If necessary, adjust the input level in one of the following ways: • Adjust the output level of the sound source or the external mixer. • If possible, use the audio hardware’s own application program to set the input levels. See the...
Page 320
MixConsole Fader Section 320 The following applies: • To copy the rack settings from one rack to another, drag the rack and drop it on the rack to which you want to copy the settings. • To move the rack settings from one rack to another, press [Alt]/[Option], drag the rack, and drop it on the rack to which you want to move the settings. • To copy the channel settings from one channel to another, drag the channel and drop it on the channel to which you want to copy the settings. You can copy rack and...