Sony Projector Srx R220 User Manual
Have a look at the manual Sony Projector Srx R220 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 980 Sony manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
21 Location and Function of Controls Rear aSTATUS MESSAGE window Displays various messages. For details on the messages, see page 22. bStatus indicators Combinations of the MAIN and LAMP indicators indicate the status of the projector as follows: z: Lights : Flashes –: Goes out cLamp adjustment window The lamp adjustment screw is inside this window. Fine adjustment of the lamp position is necessary after replacing the lamp. For adjustment, contact Qualified Sony Service Personnel. dVentilation holes (intake) (rear) eMAIN switch Turns on/off the main switch. To turn off the projector completely The projector is ready to be turned off when the LAMP indicator flashes in green then lights in red steadily. You can then turn off the MAIN switch to turn off the projector completely. You can turn on the projector in any order. For more information, refer to the Installation Manual (not supplied). fLAMP switch Turn on/off the lamp switch. gINGEST PORT connector Connects a removable drive to ingest the digital cinema contents. If you use this connector, you must make the necessary connections with this connector inside the projector housing referring to the Installation Manual when the projector is installed. For details, refer to the Installation Manual (not supplied). hRS-232C connector Connects the SRX controller. This is for service use. MAIN indicatorLAMP indicatorStatus of the projector –z (in red) The LAMP switch is turned on and the unit is in standby mode. z (in red) – The MAIN switch is turned on and the unit is in standby mode. z (in red)z (in red) The unit is in standby mode. You can turn on the unit with the controller. z (in green)z (in green) The unit is turned on with the controller. You can operate the unit with the controller. (in green) (in green)The unit is in standby after shutting it down with the controller. Cooling fans are running. z (in green) (in green)The unit is in lamp-off mode. 1 2 3 4 5 6 7 8 Note
22Messages Messages Various messages may be displayed in the STATUS MESSAGE window at the rear of the projector during operation. Displayed messages are classified into “Error messages” and “Information messages.” Error Messages Error messages are classified into three types, described below, depending on the danger level. If an error occurs, the message number and the message are displayed in the STATUS MESSAGE window. ALERT : Danger level - High Message number: ALERT_xx WARNING: Danger level - Middle Message number: WARN_xx FAILURE: Danger level - Low Message number: FAIL_xx If an error message is displayed, contact Qualified Sony Service Personnel and give them the message and its number. The error messages to be displayed are listed below. ALERT : Danger level - High Rear of the projector STATUS MESSAGE window Message number Message Message numberError messageMeaning ALERT_01 BOARD ERROR Trouble with power of IFA board ALERT_02 BOARD ERROR Trouble with power of IFB board ALERT_03 BOARD ERROR Trouble with power of IFC board ALERT_04 BOARD ERROR Trouble with power of IFD board ALERT_05 BOARD ERROR Trouble with power of MX board ALERT_06 BOARD ERROR Trouble with power of LPD board ALERT_07 BOARD ERROR Trouble with power of CT board
23 Messages WARNING: Danger level – Middle ALERT_08 BOARD ERROR Trouble with power of DST board ALERT_09 BOARD ERROR Trouble with power of PR1 board ALERT_10 BOARD ERROR Trouble with power of PR2 board ALERT_11 BOARD ERROR Trouble with power of SY board ALERT_12 BOARD DETACHED CN board disconnected ALERT_13 BOARD DETACHED MX board disconnected ALERT_14 BOARD DETACHED LPD board disconnected ALERT_15 BOARD DETACHED CT board disconnected ALERT_16 BOARD DETACHED DST board disconnected ALERT_17 BOARD DETACHED PR1 board disconnected ALERT_18 BOARD DETACHED PR2 board disconnected ALERT_19 TEMPERATURE ERROR Temperature of R panel is too high, and the unit stops operation. ALERT_20 TEMPERATURE ERROR Temperature of G panel is too high, and the unit stops operation. ALERT_21 TEMPERATURE ERROR Temperature of B panel is too high, and the unit stops operation. ALERT_22 COVER DETACHED Rear cover detached and/or internal mirror position changed ALERT_25 TEMPERATURE ERROR Temperature of lamp power is too high, and the unit stops operation. ALERT_27 FAN ERROR Abnormal in fan 2 for lamp ALERT_28 FAN ERROR Abnormal in fan 3 for lamp ALERT_29 FAN ERROR Abnormal in fan 4 for lamp ALERT_30 FAN ERROR Abnormal in fan 5 for lamp ALERT_32 BALLAST ERROR Temperature of lamp power is too high, and the unit stops operation. ALERT_33 BALLAST ERROR Abnormal in the fans for lamp power ALERT_34 BALLAST ERROR Abnormal in the lamp power ALERT_35 LAMP ERROR The lamp does not light, or goes out. ALERT_36 BALLAST ERROR Abnormal in the lamp power ALERT_37 COVER DETACHED Abnormal position of the lamp house cover ALERT_38 BOARD ERROR Trouble with power of CN board ALERT_39 TEMPERATURE ERROR Temperature of 8-inch duct attachment part is too high, and the unit stops operation. Message numberError messageMeaning Message numberError messageMeaning WARN_01 FAN ERROR Abnormal in fan 1 for the main power WARN_02 FAN ERROR Abnormal in fan 2 for the main power WARN_05 FAN ERROR Abnormal in fan for board 1 WARN_06 FAN ERROR Abnormal in fan for board 2 WARN_11 FAN ERROR Abnormal in fan for PBS B WARN_12 FAN ERROR Abnormal in fan for peltier R WARN_13 FAN ERROR Abnormal in fan for peltier G WARN_14 FAN ERROR Abnormal in fan for peltier B WARN_16 FAN ERROR Abnormal in fan for optical unit 2 WARN_18 FAN ERROR Abnormal in fan for the PSCon WARN_19 COVER DETACHED Air filter cover is open. WARN_20 DEVICE ERROR Failure of the peltier R control WARN_21 DEVICE ERROR Failure of the peltier G control
24Messages FAILURE: Danger level – Low Information Messages The message number is not displayed for information messages. Check the following if a message appears in the STATUS MESSAGE window. WARN_22 DEVICE ERROR Failure of the peltier B control WARN_23 CONNECTOR DETACHED The peltier R connector disconnected WARN_24 CONNECTOR DETACHED The peltier G connector disconnected WARN_25 CONNECTOR DETACHED The peltier B connector disconnected WARN_26 DOUSER ERROR Trouble with the douser operation WARN_27 BALLAST ERROR Failure of the ballast communication for the lamp power WARN_28 BALLAST ERROR Incorrect settings of the lamp S/N or the lamp power wattage Message numberError messageMeaning Message numberError messageMeaning FAIL_01 TEMPERATURE ERROR Temperature of the system area is too high. FAIL_02 TEMPERATURE ERROR Temperature of the projector head area is too high. FAIL_03 TEMPERATURE ERROR Temperature of the power area is too high. FAIL_04 TEMPERATURE ERROR Temperature of the intakes is too high. FAIL_06 TEMPERATURE ERROR Temperature of the optical unit area is too high. FAIL_10 TEMPERATURE ERROR Warning for abnormal temperature of Panel R FAIL_11 TEMPERATURE ERROR Warning for abnormal temperature of Panel G FAIL_12 TEMPERATURE ERROR Warning for abnormal temperature of Panel B FAIL_13 TEMPERATURE ERROR Warning for abnormal temperature of the lamp FAIL_15 TEMPERATURE ERROR Warning for abnormal temperature of the lamp power FAIL_16 LENS ERROR Failure of the zoom position adjustment to the registered setting FAIL_17 LENS ERROR Failure of the lens focus adjustment to the registered setting FAIL_18 LENS ERROR Trouble with the zoom position adjustment FAIL_19 LENS ERROR Trouble with the lens focus adjustment FAIL_21 ADJUSTMENT ERROR Abnormal in the Z-axis adjustment FAIL_24 ADJUSTMENT ERROR Failure of calibration for luminance deterioration FAIL_25 DEVICE ERROR Failure of FPGA configuration FAIL_26 DEVICE ERROR Trouble with the IIC circuit FAIL_27 DEVICE ERROR Trouble with the LVDS circuit FAIL_28 DEVICE ERROR Trouble with the PLL circuit FAIL_29 DEVICE ERROR Trouble with the PARITY circuit FAIL_30 BALLAST ERROR Lamp power interlocked FAIL_34 ADJUSTMENT ERROR Deviation of the Z-axis operation for + direction FAIL_35 ADJUSTMENT ERROR Deviation of the Z-axis operation for – direction FAIL_36 DEVICE ERROR Error of the DVI setting MessageMeaning DOUSER CLOSED Douser is closed. LAMP POWER + LIMIT Lamp power was automatically adjusted by correcting luminance deterioration, but the picture is not brighter.
25 Messages LAMP POWER – LIMIT Lamp power was automatically adjusted by correcting luminance deterioration, but the picture is not darker. LOW REAL TIME CLOCK BATTERYThe RTC battery (BT200) for the SY board should be replaced. LUMI VALUE + LIMIT Correction for luminance deterioration was made, but the picture is not brighter. LUMI VALUE – LIMIT Correction for luminance deterioration was made, but the picture is not darker. MessageMeaning
26Maintenance / Specifications Maintenance Some components of the projector are consumable parts over a long period of use. To keep the projector working properly and to prolong its usable lifetime, have the projector inspected periodically. We recommend you make a maintenance contract for periodical inspection with us. For details on the contract, consult with Qualified Sony Service Personnel. Specifications Optical characteristics Projection system SXRD (Silicon X-tal Reflective Display) 3 panel system SXRD 8,847,360 (4096 (H) × 2160 (V)) pixels × 3 Lens Optional Light output* SRX-R220: 14 ft-L For a screen max. 20 m wide using a 4.2 kW lamp For a screen max. 17 m wide using a 3.0 kW lamp For a screen max. 14 m wide using a 2.0 kW lamp SRX-R210: 14 ft-L For a screen max. 17 m wide using a 3.0 kW lamp For a screen max. 14 m wide using a 2.0 kW lamp Lamp Optional * When the screen gain is 1.8 Input/output RS-232C For service use (to connect the SRX controller) INGEST PORT For service use (to ingest the contents) Input signal DVI-D The following signals are acceptable when the optional interface board is installed. HD-SDI (4:4:4/4:2:2) (SMPTE-292M) DC-SDI (4:4:4) For details on optional interface boards, contact Qualified Sony Service Personnel. General Dimensions 740 × 1535 × 1396 mm (29 1/4 × 601/2 × 55 inches) (w/h/d) Mass Approx. 300 kg (661 lb 6 oz) (excluding the optional lamp and lens) Power requirements 100 to 240 V AC, 50/60 Hz (single-phase main power)
27 Specifications 200 to 208/380 to 415 V AC, 50/60 Hz (three-phase lamp power) Current consumption SRX-R220: 11 to 5 A (single-phase main power) 21/11 A (three-phase lamp power) SRX-R210: 11 to 5 A (single-phase main power) 13.5/7 A (three-phase lamp power) Operating temperature 5°C to 35°C (41°F to 95°F) Performance guarantee temperature 10°C to 30°C (50°F to 86°F) Operating humidity 35% to 85% (no condensation) Storage temperature –20°C to +60°C (–4°F to +140°F) Storage humidity 10% to 90% Supplied accessories Fall prevention brackets (4) Keys for removing panels (10) Keys for lamp replacement panel/lamp position adjustment (2) Operating Instructions (2) Lens cover assembly (2) Lens attachment screws (M8) (4) AC cable clampers (2 for three-phase power, 3 for single-phase power) Plug holder (B) (retaining holder for AC cable) (1) FAN harness for the system area (1) Attachment screws for clampers +PSW 4 × 8 (5) Status indicator lamp (1) Harness for status indicator lamp (1) Attachment bracket for Touch Panel Controller (TPC) (1 set) Attachment screws for status indicator lamp and TPC attachment bracket +PSW 4 × 8 (2), +B 4 × 12 (4), +B 3 × 6 (2) Edge guard (1) Optional accessories Projection lens with zoom/focus memory function * Projection ratio = Projection distance / Screen width Projection lamp LKRX-2042A (for SRX-R220) LKRX-2030A (for SRX-R220/R210) LKRX-2020A (for SRX-R220/R210) Media block LMT-100 LMT-200 Design and specifications are subject to change without notice. Model nameProjection ratio* LKRL-Z111C 1.07 to 1.71 LKRL-Z114C 1.35 to 1.98 LKRL-Z116C 1.50 to 2.29 LKRL-Z117 1.72 to 2.39 LKRL-Z119 1.81 to 2.94 LKRL-Z122 2.23 to 4.03 Note Always verify that the unit is operating properly before use. SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR REIMBURSEMENT ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS DUE TO FAILURE OF THIS UNIT, EITHER DURING THE WARRANTY PERIOD OR AFTER EXPIRATION OF THE WARRANTY, OR FOR ANY OTHER REASON WHATSOEVER.