Home > Sony > Computer Monitor > Sony Monitor Gdm F520 Manual

Sony Monitor Gdm F520 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Sony Monitor Gdm F520 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 980 Sony manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							GDM-F520(E) 1-4
    1-4. BEZEL, H2 BOARD, MAGNETIC SENSOR REMOVAL
    3Bezel
    7Input selector
    9H2 board
    5Three screws
    (+BVTP 3 x 10)
    4Screw  (+BVTP 4 x 16)
    10
    Lifting up two claws 
    in the direction of arrow.
    4Screw  
    (+BVTP 4 x 16)
    11
    L1 bracket
    12
    Magnetic MIU-221D
    sensor
    2Four tapping screws (5)
    8Menu button
    6Control panel assembly
    CN1500
    CN1401
    CN1400
    1
    Picture tube shield
    Before removing the bezel assembly, secure
       the picture tube by attaching two screws to
       the picture tube shield at the positions shown
       with an arrow (diagonal two places) to prevent 
       the picture tube from falling.
       (Use the screws +BVTT 4 x 8 that fix EMI shield.)  
    						
    							GDM-F520(E) 1-5
    1-5. D BOARD REMOVAL
    A2 board
    (C block)
    Two screws
    (+BVTT 4 x 6)
    4
    Two screws
    (+BVTP 3 x 10)
    3
    Video block assembly
    Rear plate assembly
    6
    Five screws
    (+BVTP 3 x 10)
    CN315
    CN1103
    CN1600
    CN1601
    CN1003
    CN605
    CN701
    CN501
    GND
    CN602
    CN601
    CN318
    GND
    Connector (4P) Connector (4P)
    1
    5
    2
    Screw (+BVTP 3 x 10)
    4
    D board
    7  
    						
    							GDM-F520(E) 1-6
    1-6. SERVICE POSITION
    1
    2
    4
    1
    Remove the D board.D board 2Remove the Video block assembly.3Install the Adaptor board 
    (XT MOUNT) (A-1391-123-A).4Lay the Video block assembly.
    Video block assembly
    Video block assembly
    5Install the video block assembly.
    6Put a box which is about 15cm in height 
    under the D board to fix it. 
    D board
    Box
    3  
    						
    							GDM-F520(E) 1-7
    1-7. PICTURE TUBE REMOVAL
    4
    Picture tube
    1
    Anode cap
    (Refer to page 1-8)
    2
    A2 board
    (C block)
    3
    Neck assembly
    CN3
    CN7CN2
    CN1
    GND  
    						
    							CPD-G520(E) 1-8
    3When one side of the rubber cap is
    separated from the anode button, the
    anode-cap can be removed by turning up
    the rubber cap and pulling up it in the
    direction of the arrow  c.
    •HOW  TO  HANDLE  AN  ANODE-CAP1 Don’t scratch the surface of anode-caps with sharp shaped
    material!
    2 Don’t press the rubber hardly not to damage inside of anode-
    caps!
    A material fitting called as shatter-hook terminal is built in the
    rubber.
    3 Don’t turn the foot of rubber over hardly!
    The shatter-hook terminal will stick out or damage the rubber.• REMOVAL  OF  ANODE-CAPNOTE: Short circuit the anode of the picture tube and the anode cap to the met\
    al chassis, CRT shield or carbon painted on the CRT, after
    removing the anode.•REMOVING  PROCEDURES1 Turn up one side of the rubber cap in the
    direction indicated by the arrow  a. 2
    Using a thumb pull up the rubber cap
    firmly in the direction indicated by the
    arrow  b.
    a
    b
    c
    Anode Button  
    						
    							GDM-F520(E) 1-9
    1-8. HARNESS  LOCATION
    CN602
    CN601CN604 CN1102 
    CN312 CN311
    CN318
    CN319 CN320
    CN316
    CN315
    CN303
    CN1103
    CN1003
    CN1401
    CN1500 CN1400
    CN605 CN1600
    CN1
    CN1 
    CN3
    CN1602
    CN701
    CN501
    4P
    4P5P
    CN904
    CN2601
    Picture tube A2 board
    AC inlet
    D board
    US board
    Magnetic sensor
    L2 board
    N board
    H2 board
    CN1601  
    						
    							GDM-F520(E) 2-1
    SECTION  2
    SAFETY  RELATED  ADJUSTMENT
    HV Regulator
    Circuit CheckHV Protector
    Circuit CheckBeam Current
    Protector Circuit
    Check
    When replacing or repairing the shown below table, the following
    operational checks must be performed as a safety precaution against X-ra\
    ys
    emissions from the unit.
    Part Replaced ( [)
    RV901
    HV ADJ
    * Confirm one minute after turning on the power.
    Part Replaced ( ])
    D Board C925, IC901, R901, R902, R905, R924, R925, R926, RV901, T901
    (FBT)• Mounted D Board
    D Board C920, C923, D911, D912, R903, R917, R918, R919, R920, R923, T901 (FBT)
    • Mounted D Board
    N Board IC1001, RB1001• Mounted N Board
    D Board C930, D917, R921, R932, R933, R935, T901 (FBT)
    • Mounted D Board
    N Board IC1001, RB1001 • Mounted N Board
    a) HV Regulator Circuit Check1) Turn the RV901 slowly, and adjustment so that high voltage is in thespecified range.
    [Specification]: 27.00 ± 0.05 kV
    2) Check that the voltage of D912 cathode on the D board is 17.0 V or more.
    b) HV Protector Circuit Check 1) Using external DC Power Supply, apply the voltage shown belowbetween cathode of D912 and GND, and check that the RASTER
    disappers.
    [Specification]: 19.95 + 0.00/– 0.05 V
    c) Beam Current Protector Circuit Check 1) Connect constant current source to a section between T901 (FBT)  qa
    pin and GND, and check that the RASTER disappers when the
    specified current flows to the  qa pin.
    [Specification]: 2.12 + 0.00/– 0.01 mA  
    						
    							GDM-F520(E) 3-1
    SECTION  3
    ADJUSTMENTS
    Note: Hand degauss 
    must be used on stand-by or power-off condition.
    This model has an automatic earth magnetism correction function by using\
     an earth magnetism sensor and a LCC coil.
    When using a hand degauss while monitor (LCC coil) is being operated, \
    it sometimes gets magnetized, and the system may
    not work properly as a result.
    • Landing Rough Adjustment1. Display all white pattern (or black dot pattern).
    2. Set contrast to 255.
    3. Display green plain pattern.
    4. Side back DY and roughly adjust green plain pattern to be centered on the useful screen with Purity Magnet.
    5. Adjust DY tilt.
    Note: Set ROTATION to 128 and LCC_NS to 128 when adjusting DY tilt.
    6. LIghtly tighten the DY screw.• Landing Fine AdjustmentNote: (1) After adjust W/B (9300k), measure the average of  IK with all
    white video input, while CONTRAST is maximum and
    BRIGHTNESS is center. And adjustment shall be made so that
    the miss-landing become least after aging 2H with the IK 30% of
    measured value shown above.
    (2) The magnetic field shall be BH = 0.
    (3) When adjusting at other than BH = 0, calculate the shifted value from BH = 0.
    1. Put the monitor in helmholz coil. 2. Set as follows;
    LCC_SW = 0 (LCC Correction Current = 0)
    FUNCTION_SW bit1 = (Auto Degauss = On)
    CONTRAST = 255
    3. Display green plain pattern.
    4. Degauss the iron part of chassis with a hand degausser and degauss coil.\
    5. Degauss CRT face with a hand degausser again.
    6. Input AC 230V to AC IN and turn the monitor off and on. Then auto- degauss works.
    7. Reset FUNCTION_SW bit1 to 0 (auto-degauss = off)
    8. Degauss CRT face with a hand degausser again.
    9. Attach wobbling coil to the specified place on CRT neck.
    10. Put on landing sensor to CRT face.
    11. Set LCC_SW to 12.
    12. With landing checker, adjust DY position, purity, DY center and landing of the 4 corners.
    13. Read VX and VY value which are the read out of magnetic sensor, and write to LCC_VX_REF and LCC_VY_REF.  
    						
    							GDM-F520(E) 3-2
     ± 6  ± 6  ± 6
     ± 6  ± 6  ± 6
     ± 6  ± 6  ± 6
    (µm)
    10 10 10
    10 7 10
    10 10 10(µm)
    The red and blue must be within the
    specification given right with re-
    spect to the green.
    A difference between red and blue
    must be within the specification
    given right.
    Adjust so that the green is within
    the specification given right.
    4 corner adjust target : within ± 1
    0 ± 3 0 ± 7.5 0 ± 3
    0 ± 3 0 ± 7.5 0 ± 3
    0 ± 3 0 ± 7.5 0 ± 3 (µm)
    14. Adjust landing by LCC_NS, LCC_LT, LCC_LB, LCC_RT, and
    LCC_RB. Adjustment of registers shall be limited within the following
    range.
    LCC_NS: 128 ± 15
    LCC_LT, LCC_LB, LCC_RT, and LCC_RB: 128 ± 40
    a
    b
    cd
    
    Green plain crosshatch pattern
    a and b should be equal.
    c and d should be equal.
    Plaster RTV to both sides for the upper wedge. Make sure that they settle inside DY.
    Plaster RTV to one side for other wedges.
    Set LCC_SW to 13, and Perform Service Save.
    15. Tighten DY screw within specified torque, and auto-degauss.
    Note: Torque 22 ± 2 kgcm (2.2 ± 0.2Nm) 16. Adjust the vertical angle of DY to make top and bottom pins equal (a =
    b). The horizontal angle shall not be changed (straight). Settle DY
    upright without leaning, and insert wedges firmly so that DY shall not
    move.
    17. Adjust top and bottom pins correction VR.
    18. Adjust the horizontal trapezoid distortion by DY horizontal trapezoid correction VR.  
    						
    							GDM-F520(E) 3-3
    19. Check landing at each corner and in case not in specification, adjustlanding of 4 corners with LCC_NS, LCC_LT, LCC_LB,
    LCC_RT, and LCC_RB. The limitations of registers are shown
    below.
    LCC_NS: 128 ± 15
    LCC_LT, LCC_LB, LCC_RT, and LCC_RB: 128 ± 40
    20. Remove the sensor and wobbling coil.
    21. Switch signals to R, G, and B, and then check that the pure colors have good color purity.
    22. Fix purity magnets with white paint.  
    						
    All Sony manuals Comments (0)

    Related Manuals for Sony Monitor Gdm F520 Manual