Page 11
Instructions for the installer 31 6.2 Fixing to the electric model support structure Create an opening with the dimensions shown in the figure in the work surface of the piece of furniture. The lower part of the casing must be fully accessible after the appliance has been installed. 1) A (mm)B (mm)C (mm)D (mm)E (mm)L (mm)X (mm)Y (mm) min 150min 460min 75020÷40min 50620592488 Make sure that there is a minimum of 750 mm between the hob ring flames and any shelves placed directly above them (Fig. 1)....
Page 12
Instructions for the installer 32 Obstructions: location of gas and electric connectors (measured in mm). IMPORTANT: if the appliance is mounted on a unit, make sure that a separating shelf is installed, as shown in the figure. However, if the appliance is on an oven installed under the hob, there is no need to install a separating shelf. If installed on top of an oven, the latter must be equipped with a cooling fan.
Page 13
Instructions for the installer 33 6.3 Electrical connection Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason. The plug at the end of the supply cable and the wall socket must be of the same type and must conform to the applicable legislation on electrical installations. Make sure that the supply line is suitably earthed. Fit power line with an omnipolar circuit breaker with a contact opening...
Page 14
Instructions for the installer 34 6.4 Ventilation in the premises. The room containing the appliance should have a permanent air supply in accordance with the standards in force. The room where the appliance is installed must have enough air flow needed for the regular combustion of gas and the necessary air change in the room itself. The air vents, protected by grills, must be the right size to comply with current regulations and positioned so that no part of them is obstructed, not even partially. The...
Page 15
Instructions for the installer 35 6.6 Gas connection Connection to the gas supply network can be made using a rigid copper hose or a flexible steel hose with a continuous wall and in compliance with the guidelines established by the applicable standard. Once the operation is complete, check the hose fittings for leaks using a soapy solution; never use a flame. The hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. To set it up for supply using other types of gas, see “3. ADAPTATION TO...
Page 16
Instructions for the installer 36 7. ADAPTATION TO DIFFERENT TYPES OF GAS Before carrying out the following operations, disconnect the appliance from the power supply. The appliance is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of operation with other types of gas, the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described in the following paragraphs. 7.1 Replacement of the cooking hob nozzles 1 Extract the pan...
Page 17
Instructions for the installer 37 7.2 Burner and nozzle characteristics table Burner Rated heating capacity (kW) LPG – G30/G31 28/37 mbar Nozzle diameter 1/100 mmBy-pass mm 1/100Rated capacity (W)Rated g/h G30Rated g/h G31 Auxiliar y (1)1.0550284007675 Rapid (2)2.507942800182179 Ultra-rapid (3)3.90100631600284279 Burner Rated heating capacity (kW) Natural gas – G20 20 mbar Nozzle diameter 1/100 mmReduced capacity (W) Auxiliar y (1)1.0572400 Rapid (2)2.50108800 Ultra-rapid (3)3.901351600 Burner Rated...
Page 18
Instructions for the installer 38 8. FINAL OPERATIONS After making the adjustments described above, reassemble the appliance by following in reverse the instructions reported in paragraph 7.1 Replacement of the cooking hob nozzles. After adjustment with a gas other than the preset one, replace the label on the casing of the appliance with the label corresponding to the new gas. This label can be obtained from the nearest Authorised Service Centre. 8.1 Adjusting the minimum for town and natural gas Light...