    10.2 Removing the door
    Open the door completely.
    Insert two pins into the holes on the hinges
    towards the back of them until they engage.
    Grasp the door on both sides with both hands,
    lift it forming an angle of around 30° and
    remove it.
    To reassemble the door, put the hinges in the
    relevant slots in the oven, making sure that
    grooved sections C are resting completely in
    the slots.  Lower the door and once it is in place
    remove the pins from the holes in the hinges. 
    						
    							Instructions for the installer
    90
    11.INSTALLING THE APPLIANCE
    11.1 Installing in kitchen units
    Veneers, adhesives or plastic coatings on adjacent furniture should be
    temperature-resistant (no less than 90°C). If they are not sufficiently
    temperature-resistant, they may warp over time. 
    The appliance must be installed by a qualified technician and according to the
    regulations in force.
    Depending on the type of installation, this appliance belongs to class 2,
    subclass 1 (Fig. A - Fig. B) or to class 1 (Fig. C).
    It may be installed next to walls, one of which must be higher than the worktop,
    at a minimum distance of 50 mm from the side of the appliance, as shown in
    figures A and C relative to the installation classes.
    Make sure that there is a minimum distance of 750 mm between the stoves of
    the hob and any shelf that may be installed directly above it. If a hood is installed
    above the hob, refer to the hood instruction manual to ensure the correct
    clearance is left.
    Built-in appliance (Class 2 subclass 1)
    Built-in appliance (Class 2 subclass 1)
    Free-standing appliance (Class 1) 
    						
    							Instructions for the installer
    91
    11.2 Electrical connection
    Make sure the voltage and the cross-section of the power supply line match the
    specifications indicated on the identification plate positioned on the appliance.
    Do not remove this plate for any reason. A copy of the plate is attached to the
    instructions.
    The appliance must be connected to the power supply by a qualified technician.
    Before performing any operations, switch off the power supply to the appliance.
    The appliance must be connected to earth in compliance with electrical system
    safety standards.
    Where the appliance is connected to the power grid via plug and socket, both of
    these must be of the same type and connected to the power cable in
    accordance with current standards. The socket must be accessible after the
    appliance has been built in. 
    NEVER UNPLUG BY PULLING ON THE CABLE.
    Should the earthing wire need replacing it must be longer than the conducting
    wires so that, if the plug is torn off the power cable, it is the last to be detached.
    Avoid use of adapters and shunts as these could cause overheating and a risk
    of burns.
    If a fixed connection is being used, fit the power line with an omnipolar circuit
    breaker with a contact opening gap equal to or greater than 3 mm, in an easily
    accessible position close to the appliance.
    The manufacturer declines all responsibility for damage to persons or things
    caused by non-observance of the above prescriptions or by interference with
    any part of the appliance. 
    						
    							Instructions for the installer
    92
    POSSIBLE 
    CONNECTION TYPESCABLE TYPE
    (if not present)
    380 - 415 V 3N~5-pole5 x 2.5 mm² H05V2V2-F
    380 - 415 V 2N~4-pole4 x 4 mm² H05V2V2-F
    220 - 240 V 1N~3-pole3 x 6 mm² H05V2V2-F
    •  Use H05V2V2-F cables withstanding temperatures of 90°C or higher.
    •  The values indicated above refer to the cross-section of the internal
    conductor.
    •  The tightening torque of the screws of the terminal supply wires must be 1.5
    - 2 Nm.
    The aforementioned power cables are sized taking into account the coincidence
    factor (in compliance with standard EN 60335-2-6). 
    						
    							Instructions for the installer
    93
    11.3 Positioning the skirt
    WARNING: The skirt provided is an integral part of the product; it must be
    fastened to the appliance prior to installation.
    •  Position the skirt above the top, taking care
    to align holes A with holes B.
    •  Secure the skirt to the top by tightening
    screws C.
    11.4 Positioning and levelling the appliance
    After making the electrical and/or gas connections, properly level
    the appliance on the floor to ensure better stability. Screw or
    unscrew the bottom part of the foot until the appliance is stable and
    level on the floor. 
    						
    							Instructions for the installer
    94
    11.5 Wall mounting instructions  (some markets only)
    1 Fasten a hook bolt (not supplied) into the wall at
    a height (h) of 800 mm from the floor.
    The installer must provide the hook bolt when installing the appliance.
    2 Attach the snap hook to the chain.
    3 Attach the end of the chain to the hook bolt
    fastened in the wall.
    4 Finally, connect the snap hook to the appropriate
    hole on the back of the appliance. 
    						