Instructions for the installer 93 11.2 Room ventilation and combustion extraction The room containing the appliance should have a permanent air supply in accordance with the standards in force. The room where the appliance is installed must have enough air flow for the regular combustion of gas and for the air exchange needed in the room itself. The air vents, protected by grills, must be suitably dimensioned in compliance with current standards and positioned so that no part of them is obstructed. The appliance must be kept adequately ventilated in order to eliminate the heat and humidity produced by cooking: in particular, after prolonged use, you are recommended to open a window or to increase the speed of any fans. Combustion products can be extracted by means of hoods connected to a natural draught chimney whose efficiency is assured or via forced extraction. An efficient extraction system requires precision planning by a specialist qualified in this area and must comply with the positions and distances indicated by the applicable standards. When the job is complete, the installer must issue a certificate of conformity. Extraction using a hood. Extraction without a hood. Single natural draught chimney. Single chimney with extractor fan. Directly outdoors with wall- or window-mounted extractor fan. Directly outdoors through wall. Air Combustion products Extractor fan
Instructions for the installer 94 11.3 Gas connection At the end of the installation, check for any leaks with a soapy solution, never with a flame. The tightening torque between connections that incorporate a gasket must be between 10 and 15 Nm. After carrying out any operation on the appliance, check that the gas connections are properly tightened. If the appliance is fuelled by LPG, use a standards-compliant pressure regulator and connect to the gas cylinder in accordance with the standards in force. Make sure that the feed pressure complies with the values indicated in table “12.2 Burner and nozzle characteristics table”.
Instructions for the installer 95 11.3.1 Connection with a rubber hose WARNING: The following instructions are valid solely for Class 1 installations. See fig. C in chapter “11.1 Installing in kitchen units”. Connection using a rubber hose complying with current standards is only permitted if the hose can be inspected along its entire length. The inside diameter of the hose must be 8 mm for LPG GAS and 13 mm for NATURAL GAS and CITY GAS. Installation with a standards-compliant rubber hose must be carried out so that the length of the piping does not exceed 1.5 metres; make sure that the hose does not come into contact with moving parts and that it is not crushed in any way. Verify that all following conditions are met: the hose is fixed to the hose connection with safety clamps; no part of the hose is in contact with hot walls (max. 50°C); the hose is not under traction or tension and has no kinks or twists; the hose is not in contact with sharp objects or sharp corners; if the hose is not perfectly airtight and leaks gas, do not try to repair it: verify that the hose is not past its expiry date (serigraphed on the hose itself). Make the connection to the gas mains using a rubber hose whose specifications comply with current standards (verify that the reference standard is stamped on the hose). Carefully screw the hose connector 3 to the appliance’s gas connector 1 (1/2” thread ISO 228-1), placing the seal 2 between them. The hose connector 4 can also be screwed to the hose connector 3, depending on the diameter of the gas hose used. After having tightened the hose connector(s), push the gas hose 6 onto the hose connector and secure it with the clamp 5 that is compliant with the applicable standard. 32 1 4 3 6 5
Instructions for the installer 9611.3.2 Connection with a flexible steel hose WARNING: The following instructions are valid for all types of installation, see fig. A, B, C in chapter “11.1 Installing in kitchen units”. Only use standards-compliant continuous wall steel hoses no longer than 2 metres. This type of installation can be used for both built-in and free- standing appliances. Make the connection to the gas mains using a continuous wall flexible steel hose whose specifications comply with the applicable standard. Carefully screw the connector 3 to the appliance’s gas connector 1 (1/2” thread ISO 228-1), placing the seal 2 between them. 11.3.3 Connection with a flexible steel hose with conical fitting (where present) WARNING: The following instructions are valid for all types of installation, see fig. A, B, C in chapter “11.1 Installing in kitchen units”. Only use standards-compliant continuous wall steel hoses no longer than 2 metres. This type of installation can be used for both built-in and free- standing appliances. Make the connection to the gas mains using a continuous wall flexible steel hose whose specifications comply with the applicable standard. Carefully screw the connector 3 to the appliance’s gas connector 1 (½” thread ISO 228-1), placing the seal 2 between them. Apply insulating material to the thread of the connector 3, and then tighten the flexible steel hose 4 to the connector 3. 2 1 3 2 1 4 3
Instructions for the installer 97 11.4 Electrical connection Make sure the voltage and the cross-section of the power supply line match the specifications indicated on the identification plate positioned on the appliance. Do not remove this plate for any reason. A copy of the plate is attached to the instructions. The appliance must be connected to the power supply by a qualified technician. Before performing any operations, switch off the power supply to the appliance. The appliance must be connected to earth in compliance with electrical system safety standards. Where the appliance is connected to the power grid via plug and socket, both of these must be of the same type and connected to the power cable in accordance with current standards. The socket must be accessible after the appliance has been built in. NEVER UNPLUG BY PULLING ON THE CABLE. Should the earthing wire need replacing it must be longer than the conducting wires so that, if the plug is torn off the power cable, it is the last to be detached. Avoid use of adapters and shunts as these could cause overheating and a risk of burns. If a fixed connection is being used, fit the power line with an omnipolar circuit breaker with a contact opening gap equal to or greater than 3 mm, in an easily accessible position close to the appliance. The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance.
Instructions for the installer 98 POSSIBLE CONNECTION TYPESCABLE TYPE (if not present) 220 - 240 V 1N~3-pole3 x 1.5 mm² H05V2V2-F Use H05V2V2-F cables withstanding temperatures of 90°C or higher. The values indicated above refer to the cross-section of the internal conductor. The tightening torque of the screws of the terminal supply wires must be 1.5 - 2 Nm. The aforementioned power cables are sized taking into account the coincidence factor (in compliance with standard EN 60335-2-6). 11.5 Positioning the skirt WARNING: The skirt provided is an integral part of the product; it must be fastened to the appliance prior to installation. Position the skirt above the top, taking care to align holes A with holes B. Secure the skirt to the top by tightening screws C. 11.6 Positioning and levelling the appliance After making the electrical and/or gas connections, properly level the appliance on the floor to ensure better stability. Screw or unscrew the bottom part of the foot until the appliance is stable and level on the floor.
Instructions for the installer 99 11.7 Wall mounting instructions (some markets only) 1 Fasten a hook bolt (not supplied) into the wall at a height (h) of 800 mm from the floor. The installer must provide the hook bolt when installing the appliance. 2 Attach the snap hook to the chain. 3 Attach the end of the chain to the hook bolt fastened in the wall. 4 Finally, connect the snap hook to the appropriate hole on the back of the appliance.
Instructions for the installer 100 12. ADAPTATION TO DIFFERENT TYPES OF GAS BEFORE PERFORMING ANY OPERATIONS, SWITCH OFF THE POWER SUPPLY TO THE APPLIANCE. Appliance set for gas:NATURAL GAS G20 (2H) 20 mbar pressure (see label on product) In case of operation with other types of gas, the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described in the following paragraphs. 12.1 Replacing the hob nozzles 1 Remove the pan stands, and remove all burner caps and flame-spreader crowns to access the burner casings. 2 Unscrew the nozzles using a 7 mm socket wrench. 3 Replace the burner nozzles according to the type of gas to be used (see 12.2 Burner and nozzle characteristics table). 4 Replace the burners in the correct position.
Instructions for the installer 101 12.2 Burner and nozzle characteristics table For burner arrangement, see “Instructions for the user - 6.4 Cookware diameters”. Burner Rated heating capacity (kW) Natural gas – G20 20 mbar Nozzle diameter 1/100 mmReduced capacity (W) 1Auxiliary1.0572400 2Semi-rapid1.897500 3Rapid3.0115800 4Ultra-rapid4.2135 + 751900 5Fish kettle burner1.994800 Burner Rated heating capacity (kW) LPG – G30/G31 28/37 mbar Nozzle diameter 1/100 mmReduced capacity (W)Capacity g/h G30Capacity g/h G31 1Auxiliary1.05504007675 2Semi-rapid1.865500131129 3Rapid3.085800218215 4Ultra-rapid4.291 + 461900305300 5Fish kettle burner1.968800138136
Instructions for the installer 102 12.3 Final operations After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the pan stands. Following adjustment to a gas other than the one originally set in the factory, replace the gas setting label fixed to the appliance with the one corresponding to the new gas. The label is inserted inside the nozzle pack (where present). 12.3.1 Adjusting the minimum setting for natural and city gas Light the burner and turn it to the minimum position. Extract the gas tap knob and turn the adjustment screw next to the tap rod (depending on the model) until the correct minimum flame is achieved. Refit the knob and verify that the burner flame is stable (when turning the knob rapidly from the maximum to the minimum position the flame must not go out). Repeat the operation on all the gas taps. 12.3.2 Adjusting the minimum setting for LPG In order to adjust the minimum setting with LPG, the screw at the side of the tap rod must be tightened clockwise all the way.