Page 51
47 Appendix Cleaning the lens■Use a commercially available blower or lens cleaning paper (for glasses and camera lenses) for cleaning the lens. Do not use any liquid type cleaning agents, as they may wear off the coating film on the surface of the lens. ■ As the surface of the lens can easily get damaged, be careful not to scrape or hit the lens. Cleaning the exhaust and intake vents■Use a vacuum cleaner to clean dust from the exhaust vent and the intake vent. Cleaning the projector■Ensure that you have...
Page 52
48 Maintenance Indicators About the lamp indicator ■When the remaining lamp life becomes 5% or less, (yellow) and “Change The Lamp” will be displayed on the screen. When the percentage becomes 0%, it will change to (red), the lamp will automatically turn off and then the projector will automatically enter standby mode. At this time, the lamp indicator will illuminate in red. ■ If you try to turn on the projector a fourth time without replacing the lamp, the projector will not turn on. About the...
Page 53
49 Appendix •If the temperature warning indicator illuminates, and the projector enters standby mode, follow the possible solutions above and then wait until the projector has cooled down completely before plug- ging in the power cord and turning the power back on. (At least 10 minutes.) • If the power is turned off for a brief moment due to power outage or some other cause while using\ the projector, and the power supply recovers immediately after that, the lamp indicator will illumi- nate in red and...
Page 54
50 Regarding the Lamp Lamp■It is recommended that the lamp (sold separately) be replaced when the remaining lamp life becomes 5% or less, or when you notice a significant deterioration in the pictur\ e and color quality. The lamp life (percentage) can be checked with the on-screen display. (See page 44.) ■ Purchase a replacement lamp of type AN-XR30LP from your place of purchase, nearest Sharp Authorized Projector Dealer or Service Center. Caution Concerning the Lamp■This projector utilizes a...
Page 55
51 Appendix Removing and Installing the Lamp Unit •Do not touch the glass surface of the lamp unit or the inside of the projector. •T o avoid injury to yourself and damage to the lamp, make sure you carefully follow the steps below. • Do not loosen other screws except for the lamp unit cover and lamp unit. Press STANDBY/ON on the projec- tor or STANDBY on the remote control to put the projector into standby mode. •W ait until the cooling fan stops. W arning! •Do not remove the lamp unit from the...
Page 56
52 Regarding the Lamp (Continued) Remove the lamp unit.•Loosen the securing screws from the lamp unit. Hold the lamp unit and pull it in the direction of the arrow. At this time, keep the lamp unit horizontal and do not tilt it. Resetting the Lamp Timer Reset the lamp timer after replacing the lamp. Insert the new lamp unit.•P ress the lamp unit firmly into the lamp unit compartment. Fasten the securing screws. Replace the lamp unit cover.• Align the tab on the lamp unit cover (1 ) and place it while...
Page 57
53 Appendix Connecting Pin Assignments COMPUTER Input/OutputPin No. Signal 1. Video input (red) 2. Video input (green/sync on green) 3. Video input (blue) 4. Not connected 5. Not connected 6. Earth (red) 7. Earth (green/sync on green) 8. Earth (blue) 9. Not connected 10. GND 11. Not connected 12. Bi-directional data 13. Horizontal sync signal: TTL level 14. Vertical sync signal: TTL level 15. Data clock COMPUTER/COMPONENT input and COMPUTER/COMPONENT output Terminals: mini D-sub 15 pin...
Page 58
54 RS-232C Terminal: D-sub 9 pin male connector of the DIN-D-sub RS-232C adaptor RD SD SG RS CS Signal Name Pin No. 1. 2. 3. 4. 5. 6. 7. 8. 9. I/O Reference Not connected Connected to internal circuit Connected to internal circuit Not connected Connected to internal circuit Not connected Connected to CS in internal circuit Connected to RS in internal circuit Not connected Receive Data Send Data Signal Ground Request to Send Clear to Send Input Output 15 69 CD RD SD ER SG DR RS CS CI Signal Pin No. 1. 2....
Page 59
55 Appendix RS-232C Specifications and Command Settings Computer control A computer can be used to control the projector by connecting an RS-232C serial control cable (cross type, sold separately) to the projector. (See page 24 for connection.) Communication conditions Set the serial port settings of the computer to match that of the table. Signal format: Conforms to RS-232C standard. Parity bit: None Baud rate: * 9,600 bps/115,200 bps Stop bit: 1 bit Data length: 8 bits Flow control: None * Set the...
Page 60
56 RS-232C Specifications and Command Settings (Continued) → ←POWR_1 __OK Projector Computer Commands Example: When turning on the projector, make the following setting. Computer DVINormal Stretch Border Normal Stretch Border CONTROL CONTENTS Power ONStandby mode (or 30-second startup time)COMMAND PARAMETERRETURN Power Projector Condition Lamp Name Input Change Volume Keystone AV Mute Freeze Auto Sync Resize On Off Status Status Power Status Quantity Usage Time(Hour) Usage Time(Minute) Life(Percentage)...