Home > Sharp > Projector > Sharp Xg C430x Projector Quickstart Guide

Sharp Xg C430x Projector Quickstart Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Sharp Xg C430x Projector Quickstart Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 615 Sharp manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							-31
    Setting up the Projector Using RS-232C or Telnet
    SETUP MENU (Main Menu)
    [1]IP Address
    IP address settings. (Page 34)
    [2] Subnet Mask
    Subnet mask settings. (Page 34)
    [3] Default Gateway
    Default gateway settings. (Page 34)
    [4]User Name (Factory default setting : Not Re-
    quired)
    Setting of user name for security protection. (Page 34)
    [5]Password (Factory default setting : Not Required)
    Setting of password for security protection. (Page 35)
    [6]RS-232C Baud Rate (Factory default setting :
    9600 bps)
    Baud rate settings for the RS-232C terminals. (Page
    35)
    [7] Projector Name
    It is possible to assign a projector name. (Page 35)
    [8] DHCP Client
    DHCP Client settings. (Page 35)
    [A] Advanced Setup
    Enters ADVANCED SETUP MENU. (Page 36)
    [D] Disconnect All
    Disconnect all connections. (Page 36)
    [V] View All Setting
    Displays all setting values. (Page 32)
    Can also be used with ADVANCED SETUP MENU.
    [S] Save & Quit
    Save set values and quit menu. (Page 33)
    [Q]Quit Unchanged
    Quit menu without saving setting values. (Page 33)
    Note
    •When “DHCP Client” is set to “OFF” on the pro-
    jector:
    IP address : 192.168.150.2
    Subnet mask : 255.255.255.0
    Default gateway : 0.0.0.0
    ADVANCED SETUP MENU
    [1]Auto Logout Time (Factory default setting : 5 min-
    utes)
    Setting of time until automatic disconnection of net-
    work connection. (Page 36)
    [2] Data Port (Factory default setting : 10002)
    Setting the TCP port number used when exchang-
    ing data. (Page 36)
    [5] Network Ping Test
    It is possible to confirm that a network connection
    between the projector and a computer etc. is work-
    ing normally. (Page 37)
    [6] Accept IP Addr(1)
    [7] Accept IP Addr(2)
    [8] Accept IP Addr(3)
    [9] Accept All IP Addr (Factory default setting : Ac-
    cept All)
    For improved security, it is possible to set up to three
    IP addresses allowing connection to the projector.
    Set IP addresses can be cancelled using [9] Accept
    All IP Addr. (Page 37)
    [0] Search Port (Factory default setting : 5006)
    Setting the port number used when searching for
    the projector. (Page 38)
    [!] Restore Default Setting
    Restores all setting values that can be set using the
    menu to the default state. (Page 38)
    [Q]Return to Main Menu
    Return to the main SETUP MENU. (Page 38)
    ▼SETUP MENU▼ADVANCED SETUP MENU
    ---------------------------------SETUP MENU--------------------------------
    [1]IP Address [2]Subnet Mask [3]Default Gateway
    [4]User Name [5]Password
    [6]RS-232C Baud Rate [7]Projector Name [8]DHCP Client
    [A]Advanced Setup [D]Disconnect All
    [V]View All Setting [S]Save & Quit [Q]Quit Unchanged
    setup>******************** ADVANCED SETUP MENU ***********************
    [1]Auto Logout Time [2]Data Port
    [5]Network Ping Test
    [6]Accept IP Addr(1) [7]Accept IP Addr(2) [8]Accept IP Addr(3)
    [9]Accept All IP Addr [0]Search Port
    [!]Restore Default Setting
    [Q]Return to Main Menu
    advanced> 
    						
    							-32
    View Setting Detail List
    ([V]View All Setting)
    1 11 1
    1Enter “v” and press the “Enter” key.
    Display all setting values(*).
    Enter number or symbol of item to be selected on the SETUP MENU. When setting, input the
    details to be set. Setting is carried out one item at a time, and saved at the end.
    ▼SETUP MENU
    ---------------------------------SETUP MENU--------------------------------
    [1]IP Address [2]Subnet Mask [3]Default Gateway
    [4]User Name [5]Password
    [6]RS-232C Baud Rate [7]Projector Name [8]DHCP Client
    [A]Advanced Setup [D]Disconnect All
    [V]View All Setting [S]Save & Quit [Q]Quit Unchanged
    setup>v
    Model Name : XX-XXXX
    Projector Name : XX-XXXX
    MAC Address : 08:00:1F:B1:B7:74
    DHCP Client : Enabled
    IP Address : 192.168.150.2
    Subnet Mask : 255.255.255.0
    Default Gateway : Not Used
    RS-232 Baud Rate : 9600 bps
    Password : Not Required
    **********(Advanced Status)**********
    Data Port : 10002
    Accept IP Address : Accept All
    Auto Logout Time : 5 minutes
    Search Port : 5006
    1
    *
    Set Items
    Example: When setting IP Address (change from
    192.168.150.2 to 192.168.150.3)
    1 11 1
    1Enter “1” (number of item to be set), and press
    the “Enter”  key.
    Display current IP address (*1).
    2 22 2
    2Enter IP address to be set and press the “En-
    ter” key.
    Display IP address after change (*2).
    3 33 3
    3Enter “v” and press the “Enter” key to verify
    setting detail list.
    IP address is being changed (*3).
    Note
    •Verification of setting detail list can be omitted.
    •Setting details are not effective until they have
    been saved. (Page 33)
    •If an invalid number is entered, an error message
    (“Parameter Error!”) will be displayed. ▼SETUP MENU
    ---------------------------------SETUP MENU--------------------------------
    [1]IP Address [2]Subnet Mask [3]Default Gateway
    [4]User Name [5]Password
    [6]RS-232C Baud Rate [7]Projector Name
    [8]DHCP Client[A]Advanced Setup [D]Disconnect All
    [V]View All Setting [S]Save & Quit [Q]Quit Unchanged
    setup>1
    IP Address : 192.168.150.2
    Please Enter : 192.168.150.3
    (change) —> 192.168.150.3
    ---------------------------------SETUP MENU--------------------------------
    [1]IP Address [2]Subnet Mask [3]Default Gateway
    [4]User Name [5]Password
    [6]RS-232C Baud Rate [7]Projector Name
    [8]DHCP Client[A]Advanced Setup [D]Disconnect All
    [V]View All Setting [S]Save & Quit [Q]Quit Unchanged
    setup>v
    Model Name : XX-XXXX
    Projector Name : XX-XXXX
    MAC Address : 08:00:1F:B1:B7:74
    IP Address : 192.168.150.3
    Subnet Mask : 255.255.255.0
    Default Gateway : Not Used
    RS-232C Baud Rate : 9600 bps
    Password : Not Required
    **********(Advanced Status)**********
    Data Port : 10002
    Accept IP Address : Accept All
    Auto Logout Time : 5 minutes
    Search Port : 5006
    1
    2
    3*1
    *2
    *3
    Setting up the Projector Using RS-232C or Telnet 
    						
    							-33
    Save Settings and Quit
    ([S]Save & Quit)
    Save set values and quit menu.
    1 11 1
    1Enter “s” and press the “Enter” key.
    2 22 2
    2Enter “y” and press the “Enter” key. ▼SETUP MENU
    ---------------------------------SETUP MENU--------------------------------
    [1]IP Address [2]Subnet Mask [3]Default Gateway
    [4]User Name [5]Password
    [6]RS-232C Baud Rate [7]Projector Name
    [8]DHCP Client[A]Advanced Setup [D]Disconnect All
    [V]View All Setting [S]Save & Quit [Q]Quit Unchanged
    setup>s
    All Connection will be disconnect.
    Continue(y/n)? y
    Apply New setting...Done.
    1
    2
    Quit without Saving Set-
    tings ([Q]Quit Unchanged)
    Quit menu without saving setting values.
    1 11 1
    1Enter “q” and press the “Enter” key.
    2 22 2
    2Enter “y” and press the “Enter” key. ▼SETUP MENU
    ---------------------------------SETUP MENU--------------------------------
    [1]IP Address [2]Subnet Mask [3]Default Gateway
    [4]User Name [5]Password
    [6]RS-232C Baud Rate [7]Projector Name
    [8]DHCP Client[A]Advanced Setup [D]Disconnect All
    [V]View All Setting [S]Save & Quit [Q]Quit Unchanged
    setup>q
    Quit Without Saving(y/n)? y
    Setting Unchanged.
    1
    2
    Setting up the Projector Using RS-232C or Telnet 
    						
    							-34
    IP Address Setting
    ([1]IP Address)
    Setting of IP address.
    1 11 1
    1Enter “1” and press the “Enter” key.
    2 22 2
    2Enter numerical value to be set and press the
    “Enter” key.
    Display IP address after change (*).
    Subnet Mask Setting
    ([2]Subnet Mask)
    Setting subnet mask.
    1 11 1
    1Enter “2” and press the “Enter” key.
    2 22 2
    2Enter numerical value to be set and press the
    “Enter” key.
    Display subnet mask after change (*).
    The setting procedure for each item will be explained. For the basic procedure, please refer
    to “Set Items” on page 32.
    setup>1
    IP Address :192.168.150.2
    Please Enter :192.168.150.3
    (change)      —>  192.168.150.31
    2
    *
    setup>2
    Subnet Mask :255.255.255.0
    Please Enter :255.0.0.0
    (change)      —>  255.0.0.01
    2
    *
    Default Gateway Setting
    ([3]Default Gateway)
    Setting default gateway.
    1 11 1
    1Enter “3” and press the “Enter” key.
    2 22 2
    2Enter numerical value to be set and press the
    “Enter” key.
    Display gateway address after change (*).
    Note
    •If the values for IP Address, Subnet Mask or Gate-
    way of the projector have been changed via Telnet,
    the computer cannot be connected to the projector
    depending on the computer’s network settings.
    User Name Setting
    ([4]User Name)
    Carrying out security protection using user name.
    1 11 1
    1Enter “4” and press the “Enter” key.
    2 22 2
    2Enter user name and press the “Enter” key.
    Display set user name (*).
    Note
    •User name can be up to 8 characters.
    •You can input the characters below :
    a-z, A-Z, 0-9, -, _
    •In the default state, user name is not set.
    setup>3
    note: “0.0.0.0” means “Using no default gateway.”
    Gateway Address :0.0.0.0
    Please Enter :192.168.150.1
    (change)          —>  192.168.150.11
    2
    *
    setup>4
    User Name :
    Please Enter : XX-XXXX
    (change)        —>   XX-XXXX1
    2
    *
    Setting up the Projector Using RS-232C or Telnet 
    						
    							-35
    Password Setting
    ([5]Password)
    Carrying out security protection using password.
    1 11 1
    1Enter “5” and press the “Enter” key.
    2 22 2
    2Enter password and press the “Enter” key.
    Display set password (*).
    Note
    •Password can be up to 8 characters.
    •You can input the characters below :
    a-z, A-Z, 0-9, -, _
    •In the default state, the password is not set.
    RS-232C Baud Rate Set-
    ting ([6]RS-232C Baud Rate)
    Setting of baud rate for RS-232C terminals.
    1 11 1
    1Enter “6” and press the “Enter” key.
    2 22 2
    2Select and enter the number 0, 1 or 2 and
    press the “Enter” key.
    Display set baud rate (*).
    Note
    •Set the projector’s baud rate to the same rate as
    that used by the computer.
    setup>5
    Password :
    Please Enter : sharppj
    (change)        —>   sharppj1
    2
    *
    Projector Name Setting
    ([7]Projector Name)
    It is possible to assign a projector name.
    1 11 1
    1Enter “7” and press the “Enter” key.
    2 22 2
    2Enter projector name.
    Display set projector name (*).
    Note
    •Projector name can be up to 12 characters.
    •You can input the characters below :
    A-Z, 0-9, -, _, (,), space
    (When “a-z” are input, they are converted to “A-Z”
    automatically.)
    •It is the same as the name which can be con-
    firmed or set, using RS-232C commands “PJN0”,
    “PJN1”, “PJN2” and “PJN3”.
    DHCP Client Setting
    ([8]DHCP Client)
    Setting DHCP Client to “ON” or “OFF”.
    Example: When setting DHCP Client to “ON”
    1 11 1
    1Enter “8” and press the “Enter” key.
    2 22 2
    2Enter “1” and press the “Enter” key.
    Display the obtained values (*).
    setup>6
    0 ...  9600 bps
    1 ...   38400 bps
    2 ... 115200 bps
    Baud Rate Select[0-2] :2
    RS-232C Baud Rate : 115200 bps1
    2
    *
    setup>7
    Projector Name : XX-XXXX
    Please Enter : MY XX-XXXX
    (change)       —>   MY XX-XXXX1
    2
    *
    setup>8
    note: It sets DHCP Client.
    0 ... OFF
    1 ... ON
    DHCP Select[0-1] : 1
    DHCP Client : ON
    Success get data from DHCP server.
    [MAC Address      
     ] : [08:00:1F:B1:B7:74]
    [IP Address           ] : [192.168.150.2]
    [Subnet Mask        ] : [255.255.255.0]
    [Default Gateway   ] : [0.0.0.0]
    [DHCP IP Address] : [192.168.150.1]
    1
    2
    *
    Setting up the Projector Using RS-232C or Telnet 
    						
    							-36
    Disconnecting All Connec-
    tions ([D]Disconnect All)
    It is possible to disconnect all the TCP/IP connec-
    tions currently recognized by the projector. Even if
    the COM Redirect port is fixed in the Busy status
    due to a problem, it is possible to force the Ready
    status back by carrying out this disconnection.
    1 11 1
    1Enter “d” and press the “Enter” key.
    2 22 2
    2Enter “y” and press the “Enter” key.
    Note
    •If Disconnect All is performed, the connection to
    the projector via network will be forcibly discon-
    nected.
    Entering ADVANCED
    SETUP MENU
    ([A]Advanced Setup)
    Enters ADVANCED SETUP MENU.
    1 11 1
    1Enter “a” and press the “Enter” key.
    Setting Auto Logout Time
    (ADVANCED[1]Auto Logout Time)
    If there is no input after a fixed time, the projector
    automatically disconnects network connection using
    the Auto Logout function. It is possible to set the time
    until the projector is automatically disconnected in
    units of a minute (from 1 to 65535 minutes).
    1 11 1
    1Enter “1” and press the “Enter” key.
    2 22 2
    2Enter numerical value and press the “Enter” key.
    Display set numerical value (*).
    Note
    •If the set value is made 0, the Auto Logout func-
    tion is disabled.
    •
    If an invalid number is entered, an error message
    (“Parameter Error!”) will be displayed and the
    screen returns to the ADVANCED SETUP MENU.
    Data Port Setting
    (ADVANCED[2]Data Port)
    Setting of TCP port number. It is possible to set in
    the range of 1025 to 65535.
    1 11 1
    1Enter “2” and press the “Enter” key.
    2 22 2
    2Enter numerical value and press the “Enter” key.
    Display set numerical value (*).
    Note
    •Set according to need. Normally, use with the fac-
    tory default setting.
    setup>d
    Disconnect All  Connections(y/n)?y
    Now Disconnecting...1
    2
    setup>a
    ******************** ADVANCED SETUP MENU ***********************
    [1]Auto Logout Time [2]Data Port
    [5]Network Ping Test
    [6]Accept IP Addr(1) [7]Accept IP Addr(2) [8]Accept IP Addr(3)
    [9]Accept All IP Addr [0]Search Port
    [!]Restore Default Setting
    [Q]Return to Main Menu
    advanced>1
    advanced>1
    Valid range : 0 to 65535 (minute)
    note: if you enter “0”, auto logout function will be disable.
    Auto Logout Time : 5
    Please Enter :15
    (change)        —>  151
    2
    *
    advanced>2
    Valid range :1025 to 65535
    Data Port :10002
    Please Enter :10005
    (change)          —>  100051
    2
    *
    Setting up the Projector Using RS-232C or Telnet 
    						
    							-37
    Carrying out Network Ping
    Test
    (ADVANCED[5]Network Ping Test)
    It is possible to confirm that a network connection
    between the projector and a computer etc. is work-
    ing normally.
    1 11 1
    1Enter “5” and press the “Enter” key.
    2 22 2
    2Enter IP address of device to be tested and
    press the “Enter” key.
    Display entered IP address (*1).
    Display test result (*2).
    Note
    •If the “Enter” key is pressed without entering an
    IP address, the Ping destination IP address used
    previously is entered.
    •If there is a fault with the connection, “Error: No
    answer” is displayed after a 5 second retry. In this
    case, please confirm the settings for the projector
    and the computer, and contact your network ad-
    ministrator.
    Setting of Accept IP Ad-
    dress 
    (ADVANCED[6]Accept IP
    Addr(1) - [8]Accept IP Addr(3))
    It is possible to improve security of the projector by
    allowing connection from only a prescribed IP ad-
    dress. It is possible to set up to three IP addresses
    allowing connection to the projector.
    1 11 1
    1Enter “6”, “7” or “8” and press the “Enter” key.
    2 22 2
    2Enter numerical value and press the “Enter” key.
    Display set numerical value (*).
    Note
    •To invalidate the Accept IP Address being cur-
    rently set, enter “0.0.0.0”.
    •If there is one or more Accept IP Addr being set,
    no connections are allowed from IP addresses
    that are not yet set. They can be cancelled using
    [9]Accept All IP Addr.
    Accepting All IP Addresses
    (ADVANCED[9]Accept All IP Addr)
    Removes IP addresses set with “Accept IP Addr”.
    1 11 1
    1Enter “9” and press the “Enter” key.
    2 22 2
    2Enter “y” and press the “Enter” key.
    Note
    •At the point in time where “y” was entered, the
    numerical values for Accept IP Addr(1)-(3) are
    reset to “0.0.0.0”.
    •If “n” is entered, setting is not altered.
    advanced>5
    Ping dest IP addr :192.168.150.1
    Please Enter :192.168.150.152
    (change)         —>  192.168.150.152
    32 bytes from 192.168.150.152: icmp_seq = 1, time = 0 ms
    32 bytes from 192.168.150.152: icmp_seq = 2, time = 0 ms
    32 bytes from 192.168.150.152: icmp_seq = 3, time = 0 ms
    32 bytes from 192.168.150.152: icmp_seq = 4, time = 0 ms1
    2
    *1
    *2advanced>6
    Accept IP Addr(1) : 0.0.0.0
    Please Enter : 192.168.150.152
    (change)         —>   192.168.150.1521
    2
    *
    advanced>9
    Accept All  IP Addresses(y/n)?  y1
    2
    Setting up the Projector Using RS-232C or Telnet 
    						
    							-38
    Setting of Search Port
    (ADVANCED[0]Search Port)
    Sets the port number used when searching for the
    projector from the network.
    1 11 1
    1Enter “0” and press the “Enter” key.
    2 22 2
    2Enter numerical value and press the “Enter” key.
    Display set numerical value (*).
    Note
    •Set according to need. Normally, use with the fac-
    tory default setting.
    Return to Default Settings
    (ADVANCED[!]Restore Default
    Setting)
    Returns all menu setting values to the default state.
    1 11 1
    1Enter “!” and press the “Enter” key.
    2 22 2
    2Enter “y” and press the “Enter” key.
    Note
    •If the values for IP Address, Subnet Mask or Gate-
    way of the projector have been returned to the
    default settings via Telnet, the computer cannot
    be connected to the projector depending on the
    computer’s network settings.
    Return to Main Menu
    (ADVANCED[Q]Return to Main Menu)
    Returns to the main SETUP MENU.
    1 11 1
    1Enter “q” and press the “Enter” key.
    Returns to the SETUP MENU.
    advanced>0
    Please Enter Port Number for Search from Computer.
    Valid range : 1025 to 65535
    Search Port : 5006
    Please Enter : 5004
    (change)         —>   50041
    2
    *
    advanced>!
    Restore All Setting to Default(y/n)? y
    — User Setting Initialized —1
    2
    advanced>q
    ---------------------------------SETUP MENU--------------------------------
    [1]IP Address [2]Subnet Mask [3]Default Gateway
    [4]User Name [5]Password
    [6]RS-232C Baud Rate [7]Projector Name [8]DHCP Client
    [A]Advanced Setup [D]Disconnect All
    [V]View All Setting [S]Save & Quit [Q]Quit Unchanged
    setup>1
    Setting up the Projector Using RS-232C or Telnet 
    						
    							-39
    1Click “Start” – “All Programs” –
    “Accessories” – “Communica-
    tions” – “HyperTerminal”.
    •If you do not have HyperTerminal in-
    stalled, see the operation manual of your
    computer.
    •Depending on the settings of your com-
    puter, you may be required to enter your
    area code and other details. Enter the
    information as required.
    2Enter a name in the “Name” field,
    and click “OK”.
    3If you are required to enter the
    area code, enter it in the “Area
    code” field. From the “Connect
    using” drop-down menu, select
    “TCP/IP (Winsock)”, and click
    “OK”.
    4Enter the IP address of the pro-
    jector in the “Host address” field
    (see “TCP/IP” on the “Network”
    menu of the projector), and en-
    ter the data port of the projector
    in the “Port number” field
    (“10002” is the factory default
    setting), and click “OK”.
    Resetting the Lamp Timer of the Projector via LAN
    When the projector is connected to a network, you can use HyperTerminal or a similar com-
    munications program to send a command to reset the lamp timer. The example below uses
    Windows
    ® XP as the operating system.
    Select
    “TCP/IP (Winsock)” 
    						
    							-40
    Resetting the Lamp Timer of the Projector via LAN
    5Click “Properties” on the “File”
    menu.
    6Click the “Settings” tab, and
    then click “ASCII Setup”.
    7Select the check boxes next to
    “Send line ends with line feeds”,
    “Echo typed characters locally”,
    and “Append line feeds to in-
    coming line ends”, and click
    “OK”.
    •The LAMPRESET Properties window
    appears, click “OK”.
    8If a user name and/or password
    is set for the projector, enter the
    user name and password.
    9Send the lamp reset command
    “LPRE0001”.
    •This command can only be sent when
    the projector is in standby mode.
    •When “OK” is received, this indicates
    that the lamp was successfully reset.
    10Close HyperTerminal. 
    						
    All Sharp manuals Comments (0)

    Related Manuals for Sharp Xg C430x Projector Quickstart Guide