RCD2200M 5 – 3 [3] DESCRIPTION AND FUNCTION OF COMPONENTS 1. DOOR OPEN MECHANISM 1. The handle lever is pulled. 2. The upper and lower latch heads are lifted up by the linked latch lever. 3. The latch lever is lifted up by the handle lever. 4. Now both latch heads are lifted up, so they can be released from the latch hook. 5. Now the door can be opened. Figure D-1. Door Open Mechanism 2. DOOR SENSING SWITCH The door sensing switch is activated by the latch head of the door and switch lever C. When the door is opened, the contacts of the switch open and interrupt the circuit to the coils of the primary interlock relay. The contacts of the primary relay then open and interrupt the circuit to the primary winding of the power transformers. 3. SECONDARY INTERLOCK SWITCHES (1), (2) The secondary interlock switches (1), (2) are activated by the upper latch head of the door and switch lever B. When the door is opened, the contacts of the switch open and interrupt the circuit to the primary winding of the power transformers (1), (2). 4. MONITOR SWITCHES (1), (2) The monitor switches (1), (2) are mounted in the upper position of the latch hook. The monitor switches are activated by the upper latch head of the door and switch lever A. When the door is opened, the contacts of the monitor switches close. Monitor switch (1) is intended to render the oven inoperative by means of blowing the monitor fuse, when the contacts of the primary interlock relay and secondary interlock switch (1) fail to open when the door is opened. Monitor switch (2) is intended to render the oven inoperative by means of blowing the monitor fuse, when the contacts of the primary interlock relay and secondary inter- lock switch (2) fail to open when the door is opened. Functions: With the door shut, the contacts of the door sensing switch and the secondary interlock switches (1), (2) are closed and the contacts of the monitor switches (1), (2) are open. 1. When the door is opened, the contact of the door sensing switch and secondary interlock switches (1), (2) are opened first, then the contact of the monitor switches (1), (2) are closed. 2. As the door goes to a closed position, the contacts of the monitor switches (1), (2) are opened first, then the contacts of the door sensing switch and the secondary interlock switches (1), (2) close.3. If the door is opened, and the contacts of the primary interlock relay and secondary interlock switch of the same circuit fail to open, the monitor fuse blows simultaneously with closing of the monitor switch contacts of that circuit (1 or 2). CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE TEST THE DOOR SENSING SWITCH, PRIMARY INTERLOCK RELAY, SECONDARY INTERLOCK SWITCHES (1), (2), DOOR SENSING SWITCH AND MONITOR SWITCHES (1), (2) FOR PROPER OPERATION. (REFER TO CHAP- TER “TEST PROCEDURE”). NOTE: MONITOR FUSE AND SWITCH ARE REPLACED AS AN ASSEMBLY. 5. MONITOR FUSE 1. The monitor fuse blows when the contacts (COM-NO) of the pri- mary interlock relay (RY1) and secondary interlock switch remain closed with the oven door open and when the monitor switch closes. 2. If the wire harness or electrical components are short-circuited, this monitor fuse blows to prevent an electric shock or fire hazard. 6. MAGNETRON TEMPERATURE FUSES (1), (2) The temperature fuses (1), (2) located on the top of the upper and lower waveguide, are designed to prevent damage to the magnetrons (1), (2). If an over heated condition develops in the tube due to blower motor failure, obstructed air ducts, dirty or blocked air intake, etc., the circuit to the magnetrons are interrupted. Under normal operation, the temperature fuses remains closed. However, when abnormally high temperatures are generated within the magnetron, the temperature fuse will open at 302°F (150°C) causing the microwave energy to stop. The defective temperature fuse must be replaced with new rated one. 7. OVEN TEMPERATURE FUSE The temperature fuse, located on the side of the exhaust duct assem- bly, is designed to prevent damage to the oven by fire. If the food load is overcooked, by either error in cook time or defect in the control unit, the temperature fuse will open. Under normal operation, the oven tem- perature fuse remains closed. However, when abnormally high tem- peratures are generated within the oven cavity, the oven temperature fuse will open at 248°F (120°C), causing the oven to shut down. The defective temperature fuse must be replaced with new rated one. 8. EXHAUST THERMISTOR The exhaust thermistor is located on the side of the exhaust duct assembly. The temperature in the exhaust duct is detected through the resistance of the thermistor. If the temperature is high, the control panel will display”EE7” and the oven will stop to avoid overheating and catching fire. If the thermistor is open, the control panel will display “EE8” and the oven will stop. 9. MAGNETRON THERMISTOR The thermistor is a negative temperature coefficient type. The air tem- perature around the upper and lower magnetrons is detected through the resistance of the thermistor. If the temperature is high, the control panel will display “EE7” and the oven will stop to protect the magne- trons against overheat. If the magnetron thermistor is open, the control panel will display “EE8” and the oven will stop. 10. FAN MOTORS The fan motors drive blades which draw external cool air into the oven. This cool air is directed through the air vanes surrounding the magne- trons and cools the magnetrons. This air is channelled through the oven cavity to remove steam and vapours given off from the heating foods. It is then exhausted through the exhausting air vents at the oven cavity. Latch hook Latch lever Monitor switch (2) Secondary interlock switch (2) Secondary interlock switch (1) Door sensing switch Monitor switch (1) Switch lever A Switch lever B Switch lever C Latch head Latch head Handle lever
RCD2200M 5 – 4 During cooking, they operate. After cooking, they will operate at least for 1 minute and the maximum operating time is 4 minutes. When the temperature of the magnetron thermistor becomes bellow 110°C, the fan motors will stop. These two (2) fan motors are D.C. motors. 11. EXHAUST MOTOR The exhaust motor is located on the side of the exhaust duct assem- bly. This motor drives a blade in the exhaust duct assembly. The driven blade draws the external cool air into the oven from the intake duct assembly. Then it sends the air out of the oven through the exhaust duct assembly. During cooking, the exhaust motor operates. After cooking, it will operate at least for 1 minute and the maximum operating time is 4 minutes. When the temperature of the exhaust thermistor becomes bellow 65°C, the exhaust motor will stop. This motor is D.C. motor. NOTE: Do not disconnect the power supply from the exhaust motor when it is turned on. Or it may be out of order. 12. ANTENNA MOTORS The upper and lower antenna motors drive antennas to radiate the microwave. 13. EXHAUST FAN The exhaust fan is located to the rear cover. It sends the air (which is at the top of the oven cavity) out of the oven. This motor is D.C. motor. 14. ANTENNA SENSOR The antenna sensors are located to the top and bottom of the oven cavity. And they watch if the antennas are rotating or not. 15. MIROWAVE SENSOR The microwave sensor is located on the top of the oven cavity. And it watch if the microwave is radiated into the oven cavity or not. 16. FUSE 12A (1) (2) 1. If the wire harness or electrical components are short-circuited, this fuse blows to prevent an electric shock or fire hazard. 2. The fuse also blows when the asymmetric rectifier, H.V. rectifier, H.V. wire harness, H.V. capacitor, magnetron or secondary winding of high voltage transformer is shorted. 17. H.V. ASYMMETRIC RECTIFIER (1) (2) The H.V.asymmetric rectifiers (1) (2) are solid state devices that pre- vent current flow is both directions. And they prevent the temperature rise of the high voltage transformers (1) (2) by blowing the fuses 12A (1) (2) when the high voltage rectifiers (1) (2) are shorted. The rated peak reverse voltage of D1 of the asymmetric rectifier is 6 KV. The rated peak reverse voltage of D2 of the asymmetric rectifier is 1.7 KV. D1 and D2 of the asymmetric rectifier or high voltage rectifier are shorted when the each peak reverse voltage goes beyond the each rated peak reverse voltage. (The process of the blowing the fuse 12A.) NOTE: The H.V.asymmetric rectifier is assembled with the high volt- age rectifier actually. 1. The high voltage rectifier is shorted by some fault when microwave cooking or dual cooking. 2. The peak reverse voltage of D2 of the rectifier goes beyond the rated peak reverse voltage 1.7 KV in the voltage doubler circuit. 3. D2 of the rectifier is shorted.4. The large electric currents flow through the high voltage winding of the high voltage transformer. 5. The large electric currents beyond 12A flow through the primary winding of the high voltage transformer. 6. The fuse 12A blows by the large electric currents. 7. The power supplying to the high voltage transformer is cut off. 18. OVEN LAMP The oven cavity light illuminates the interior of the oven so that food being cooked can be examined visually through the door window with- out having to open the door. 19. NOISE FILTER The noise filter prevents the radio frequency interference that might flow back in the power circuit. D2 D1 ASYMMETRIC RECTIFIER HIGH VOLTAGE RECTIFIER
RCD2200M 6 – 2 Home fuse blows when power cord is plugged into wall receptacle It seems that the output power is lower or higher than the rated one. Monitor fuse blows when power cord is plugged into wall receptacle. " . " does not appear in display when power cord is first plugged into wall receptacle. Oven lamp does not go on for 1 minute after door is opened. Oven lamp and antenna motors do not go on in cook cycle. Oven goes into a cook cycle but shuts down before and off cooking cycle. Oven does not go into cook cycle when START pad is touched. Low or no power is produced during cooking condition. (The food is heated incompletely or not heated at all.) Variable cooking does not operates properly, except HIGH power functions. Fan motor does not operate. Exhaust fan does not operate. Exhaust motor does not operate. Oven doen not go into cook cycle when START pad on the door is touched. OFF CONDITION CONDITION PROBLEM COOKING CONDITION POSSIBLE CAUSE AND DEFECTIVE PARTSTEST PROCEDURE MAGNETRON (1), (2) POWER TRANSFORMER (1), (2) H.V. RECTIFIER ASSEMBLY (1), (2) HIGH VOLTAGE CAPACITOR (1), (2) SECONDARY INTERLOCK SWITCH (1), (2) PRIMARY INTERLOCK SYSTEM DOOR SENSING SWITCH MONITOR SWITCH (1), (2) MONITOR FUSE MAGNETRON TEMP. FUSE (1), (2) OVEN TEMPERATURE FUSE OVEN LAMP OR SOCKET FAN MOTORS EXHAUST FAN EXHAUST MOTOR FUSE 12A (1), (2) VOLTAGE SELECT RELAY (1), (2) EXHAUST THERMISTOR MAGNETRON THERMISTOR NOISE FILTER KEY UNITS POWER UNIT RELAY UNIT CONTROL UNIT SWITCH UNIT. AIR FLOW BLOCKED LOOSE WIRING SHORT IN POWER SUPPLY CORD NO POWER AT OUTLET LOW POWER SUPPLY VOLTAGE AB CDEF FGH JJ I LK NPQOM
RCD2200M 6 – 3 SPECIFICATION OF ERROR Outline Operation when error occurs Display in operation usually When a basic performance and the function are ruined Displaying and heating stop EE0, EE1, EE2, EE3, EE8 When the dangers of the state of the high temperature and the ignition, etc. are foreseenDisplaying and heating stop EE7 When you mistake the setting of the heating time Operation stop EE9 When neither the power supply nor the environmental condition are proper Operation stop EE4, EE5, EE6 When informing of the exchange time of parts Display Only CC1, CC2, CC3, CC4 Display for maintenance Error his- tory displayContent of maintenance Check itemParts to be replaced CC1 CC2 CC3 CC4 {– MG1 exchange time information Using time of MG1 MG1 {– MG2 exchange time information Using time of MG2 MG2 {– Exhaust Fan motor exchange time information Using time of Exhaust motor Exhaust motor {– T/C unit exchange time information Using number of times of RY2/RY3 Relay unit A TEST PROCEDURE POSSIBLE CAUSE AND DEFECTIVE PARTS BDC E F I JK L QORR S EE0 EE0 EE0 EE0 EE0 EE0 EE0EE1 EE1 EE2 EE2EE3 EE3 EE3EE4 EE5 EE6 EE6EE7 EE7 EE7EE8 EE8 EE8 EE8 EE8 EE8 EE8 EE8 EE8EE9 Magnetron 1and /or 2 Power transformer 1 & 2 High voltage capacitor 1 and /or 2 H.V.rectifier assembly 1 and/or 2Secondary interlock switch 1 and/orPrimary interlock system Fuse 12A 1 and/or 2 Magnetron temp. fuse 1 and/or 2 Magnetron thermistor 1 and/or 2 Exhaust thermistor Fan motors Exhaust motor Antenna motor 1 and/or 2 Air flow blocked Low or High power supply voltage No load or small load operation Loose wiring Exceeding of maxmum cooking time Burned food Relay unit Control unit Antenna sensor (1) (Upper) Antenna sensor (2) (Lower) Microwave sensor EE 1Failer of high voltage circuit 1EE 2Failer of high voltage circuit 2EE 3Failer of high voltage circuit 1&2EE 4Too high of input voltage(+13%)EE 5Too low of input voltage(-13%)EE 7Food burned (temp., too high)EE 8Melted contacts of relaysEE 9Over maximum cooking timeEE 10EEPROM errorEE 11Life end of magnetron 1EE 21Life end of magnetron 2EE 31Life end of magnetron 1&2EE 81Life end of relays RY2/RY3EE 83Over Current errorEE 14MG1 Cooling Fan lock judgeEE 24MG2 Cooling Fan lock judgeEE 44Exhaust motor lock judgeEE 54Life end of exhaust motorEE 15MG1 antenna rotation errorEE 25MG2 antenna rotation errorEE 35MG1/2 antenna rotation errorEE 16MG1 thermistor openEE 26MG2 thermistor openEE 17MG1 temperature, too high EE 27MG2 temperature, too high EE 18Magnetron 1 EE 28Magnetron 2 EE 38Magnetron 1& 2 EE 29Exhaust thermistor open/short EE 19No food EE 39small food Error history displayUsual error displayContent of error If the power supply voltage is higher than 230V+13% (259.9V), EE4 will be displayed. If the power supply voltage is lower than 208V-13% (180.96V), EE5 will be displayed. NOTE 1: " " means that the parts should be replaced when EE11, EE21, EE31 or EE81 is indicated on the display. NOTE 2:
RCD2200M 7 – 2 4. Isolate the high voltage rectifier assembly from the HV circuit. The high voltage rectifier can be tested using an ohmmeter set to its highest range. Connect the ohmmeter across the terminal B+C of the high voltage rectifier and note the reading obtained. Reverse the meter leads and note this second reading. The normal resistance is infinite in one direction and more than 100k ohms in the other direction. 5. Reconnect all leads removed from components during testing. 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. 2. ASYMMETRIC RECTIFIER TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge two high voltage capacitors. 4. Isolate the high voltage rectifier assembly from the HV circuit. The asymmetric rectifier can be tested using an ohmmeter set to its highest range across the terminals A+B of the asymmetric rectifier and note the reading obtained. Reverse the meter leads and note this second reading. If an open circuit is indicated in both directions then the asymmetric rectifier is good. If the asymmetric rectifier is shorted in either direction, then the asymmetric rectifier is faulty and must be replaced with high voltage rectifier. When the asymmetric rectifier is defective, check whether magne- tron, high voltage rectifier, high voltage wire or filament winding of the high voltage transformer is shorted. 5. Reconnect all leads removed from components during testing. 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. NOTE: Be sure to use an ohmmeter that will supply a forward bias voltage of more than 6.3 volts. [4] D: HIGH VOLTAGE CAPACITOR (1) AND/OR (2) TEST 1. Disconnect the power supply cord, and then remove outer case and rear cover. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input leads and check for short or open between the termi- nals using an ohmmeter. Checking with a high ohm scale, if the high voltage capacitor is normal, the meter will indicate continuity for a short time and should indicate an open circuit once the capacitor is charged. If the above is not the case, check the capacitor with an ohmmeter to see if it is shorted between either of the terminals and case. If it is shorted, replace the capacitor. 5. Reconnect all leads removed from components during testing. 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. [5] E: SECONDARY INTERLOCK SWITCH (1) AND/OR (2) TEST 1. Disconnect the power supply cord, and then remove outer case and rear cabinet. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal of the switch. The meter should indicate an open circuit with the door open and a closed circuit with the door closed. If improper operation is indicated, replace the secondary interlock switch. 5. Reconnect all leads removed from components during testing. 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. D2 D1 ASYMMETRIC RECTIFIER HIGH VOLTAGE RECTIFIERAB C
RCD2200M 7 – 3 [6] F: PRIMARY INTERLOCK SYSTEM TEST 1. DOOR SENSING SWITCH 1. Disconnect the power supply cord, and then remove outer case and rear cabinet. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal of the switch. The meter should indicate an open circuit with the door open and a closed circuit with the door closed. If improper operation is indicated, replace the door sensing switch. 5. Reconnect all leads removed from components during testing. 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. NOTE: If the door sensing switch contacts fail in the open position and the door is closed, the blower motor, stirrer motors and oven light will be acti- vated by RY1. 2. PRIMARY INTERLOCK RELAY RY1 1. Disconnect the power supply cord, and then remove outer case and rear cabinet. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Disconnect two (2) wire leads from the male tab terminals of the Primary Interlock Relay RY1. Check the state of the relay contacts using a ohm- meter. The relay contacts should be open. If the relay contacts are closed, replace the circuit board entirely or the relay itself. 5. Reconnect all leads removed from components during testing. 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. [7] G: MONITOR SWITCH (1) AND/OR (2) TEST 1. Disconnect the power supply cord, and then remove outer case and rear cabinet. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Before performing this test, make sure that the secondary interlock switches (1), (2) and the primary interlock relay RY1 are operating properly, according to the above Switch Test Procedure. Disconnect the wire lead from the monitor switches (1), (2) (COM) terminals. Check the monitor switches (1), (2) operation by using the ohmmeter as follows. When the door is open, the meter should indicate a closed circuit. When the monitor switch actuator is pushed by a screw driver through the upper latch hole on the front plate of the oven cavity with the door opened (in this condition the plunger of the monitor switch is pushed in), the meter should indicate an open circuit. If improper operation is indicated, the switch may be defective. After testing the monitor switches, reconnect the wire lead to the monitor switch (COM) terminals and check the continuity of the monitor circuit. 5. Reconnect all leads removed from components during testing. 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. [8] H: BLOWN MINITOR FUSE TEST 1. Disconnect the power supply cord, and then remove outer case and rear cabinet. 2. Open the door and block it open. Screw Driver Ohmmeter Monitor switch (2) Latch hook Monitor switch (1)
RCD2200M 7 – 4 3. Discharge high voltage capacitor. 4. If the monitor fuse is blown when the door is opened, check the primary interlock relay RY1, secondary interlock switches (1), (2) and monitor switches (1), (2) according to the “TEST PROCEDURE” for those switches before replacing the blown monitor fuse. CAUTION: CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE, TEST THE PRIMARY INTERLOCK RELAY, SECONDARY INTERLOCK SWITCHES, DOOR SENSING SWITCH AND MONITOR SWITCHES FOR PROPER OPERATION. If the monitor fuse is blown by improper switch operation, the monitor fuse and monitor switch must be replaced with “monitor fuse and monitor switch assembly” part number FFS-BA033WRKZ, even if the monitor switch operates normally. The monitor fuse and monitor switch assembly is comprised of a 20 ampere fuse and switch. 5. Reconnect all leads removed from components during testing. 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. [9] I: FUSE 12A (1) (2) TEST 1. Disconnect the power supply cord, and then remove outer case and rear cabinet. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the fuse is blown, check the magnetron, high voltage capacitor, high voltage rectifier assembly, according to the “TEST PROCEDURE” before replacing the blown fuse. Then replace the fuse. 5. Reconnect all leads removed from components during testing. 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. [10] J: TEMPERATURE FUSE TEST 1. Disconnect the power supply cord, and then remove outer case and rear cabinet. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. A continuity check across the temperature fuse terminals should indicate a closed circuit unless the temperature of the temperature fuse reaches specified temperature as shown below. 5. Reconnect all leads removed from components during testing. 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. CAUTION: IF THE TEMPERATURE FUSE INDICATES AN OPEN CIRCUIT AT ROOM TEMPERATURE, REPLACE TEMPERATURE FUSE. [11] K: MAGNETRON THERMISTOR TEST 1. Disconnect the power supply cord, and then remove outer case and rear cabinet. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Disconnect the connector of the magnetron thermistor from the harness. Measure the resistance of the thermistor with an ohmmeter. Connect the ohmmeter leads to the connector of the thermistor. If the meter does not indicate above resistance, replace the thermistor. 5. Reconnect all leads removed from components during testing.Open temperature Close temperature Display or ConditionCheck point Magnetron temperature fuse (1) 150°C Non resetable typeEE1Magnetron (1) Failure: Test magnetron (1) and fan motor. Magnetron temperature fuse (2)EE2Magnetron (2) Failure: Test magnetron (2) and fan motor. Magnetron temperature fuse (1), (2)EE3Magnetron (1), (2) Failure: Test magnetron (1), (2). Check fan motor and ventilation opening. Oven temperature fuse 120°C Non resetable type Oven shut offFood has been burned in oven. Temperature of oven inside is very high. Room temperature Resistance 68°F (20°C) Approx. 750KΩ
RCD2200M 7 – 5 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. [12] L: EXHAUST THERMISTOR TEST The exhaust thermistor can be checked by using the Special function (SF-6). Check the exhaust thermistor, referring to the pages of the Exhaust ther- mistor check (SF-6). If the display shows “OH”, the exhaust thermistor is normal. If the display shows “no”, the exhaust thermistor is abnormal and it should be replaced. [13] M: NOISE FILTER TEST 1. Disconnect the power supply cord, and then remove outer case and rear cabinet. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Disconnect the lead wires from the terminal the noise filter. Using an ohmmeter, check between the terminals as described in the following table. If incorrect reading are obtained, replace the noise filter. 5. Reconnect all leads removed from components during testing. 6. Reinstall the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord after the rear cover and the outer case are installed. 8. Run the oven and check all functions. [14] N: KEY UNIT TEST 1. Disconnect the power supply cord, and then remove outer case and rear cabinet. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Check Key unit ribbon connection before replacement. 5. If key unit ribbon connection is normal, carry out the following procedures. 6. Re-install the rear cover and the outer case (cabinet). 7. Reconnect the power supply cord. 8. The following symptoms indicate a defective key unit. 1) When touching the pads, a certain pad produces no signal at all. 2) When touching a number pad, two figures or more are displayed. 3) When touching the pads, sometimes a pad produces no signal. 9. When you can not judge if the key unit is normal or not by using the item 8 above, carry out following test procedures. 1) Disconnect the power supply cord, and then remove outer case and rear cover. 2) Open the door and block it open. 3) Discharge two high voltage capacitors. 4) Disconnect the leads to the primary of the power transformer. 5) Ensure that these leads remain isolated from other components and oven chassis by using insulation tape. 6) Reconnect the power supply cord. 7) If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable is making good contact, verify that the door sensing switch (stop switch) operates prop- erly; that is the contacts are closed when the door is closed and open when the door is open. If the door sensing switch (stop switch) is good, disconnect the flat ribbon cable that connects the key unit to the control unit and make sure the door sensing switch is closed (either close the door or short the door sensing switch connector). Use the Key unit matrix indicated on the control panel schematic and place a jumper wire between the pins that correspond to the STOP/CLEAR pad making momentary contact. If the control unit responds by clearing with a beep the key unit is faulty and must be replaced. If the control unit does not respond, it is faulty and must be replaced. If a specific pad does not respond, the above method may be used (after clearing the control unit) to determine if the control unit or key pad is at fault. MEASURING POINT INDICATION OF OHMMETER Between source terminals Approx. 470KΩ Between source (Black) and load (Black) terminals Short circuit. Between source (White) and load (White/Brown) terminals Short circuit. FUSE 20A NOISE FILTER NOISE SUPPRESSION COILLINE CROSS CAPACITOR 1.0μF / AC 250V DISCHARGE RESISTOR 470K 1/2W LINE BYPASS CAPACITOR 0.0033μF / AC 125V LINE BYPASS CAPACITOR 0.0033μF / AC 125V Load (Black) Load (White/Brown)Source (White)Source (Black) 5432 7 8 9 61 2 3 4 1 5 6 72 3 4 1 5 6 72 3 4 1 5 6 7 8 STOP CLEAR 1 START 3 4 956 07 8 STOP CLEAR 12 X2/X3 START 3 4 956 07 8 CN-M CN-R CN-Z 2 CUSTOM HELP SET MEMORYEXPRESS DEFROSTSELECT TIME SELECT POWER CN-Q< KEY UNIT >