Installation Runco VX-44d/-55d Owner’s Operating Manual 29 PREL IMINARY 3.7 Connections to the VX-44d/-55d and DHD Controller Proceed as follows to connect the DHD Controller to the VX-44d/-55d, your video sources, external controller(s) – if present – and AC power. When connecting your equipment: Turn off all equipment before making any connections. Use the correct signal cables for each source. Ensure that the cables are securely connected. Tighten the thumbscrews on connectors that have them. Connector Panel AccessTo access the connector panel, pull firmly on the cable access cover to open it. Connecting the DHD Controller to the VX-44d/-55d Connect the HDMI and RS-232 outputs from the DHD Controller to the corresponding inputs on the VX-44d/-55d; see Figure 3-8. Figure 3-8. Connecting the VX-44d/-55d to the DHD Controller Pb Pr Y Video3 IR RS-232 Control S-Video 1 S-Video 2 HD1 HD212 R/Pr G/Y B/Pb R/Pr G/Y B/Pb H V HDMI 1 HDMI 2 HDMI OutHVTRIGGERS RS-232 OutCAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER- SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE CENTER. AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR CAUTIONRISK OF ELECTRIC SHOCK DO NOT OPEN! WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. 100-230VAC 50-60 Hz, 165 Watts Max INPUTSSYSTEM CONTROL INTERFACE Component Video SDI Option Serial No Video Processor / ControllerModel Runco International Union City, CA Made In USA HDMI OUTRS-232 OUT
Installation 30 Runco VX-44d/-55d Owner’s Operating Manual PREL IMINARY Connecting Source Components to the DHD Controller Connect your video sources to the DHD Controller as shown and described in the sections that follow. Connect your video sources to the DHD Controller as shown and described in the sections that follow. HDMI Connections: See Figure 3-9. Figure 3-9. HDMI Source Connections ➤ Use the HDMI inputs whenever possible. This ensures the highest video quality because the signal is carried in the digital domain throughout the entire signal path, from source component output into the projector. Tip HD1 HD2 G/YINPUTS HV R/Pr B/PbG/Y H V R/Pr B/Pb Component Video Pb Pr Y Video S-Video 2S-Video 1IR 12 3TRIGGERS HDMI 1 HDMI 2 HDMI Source (HD-DVD/BD/DVD Player or HD Tuner with HDMI or DVI out)
Installation Runco VX-44d/-55d Owner’s Operating Manual 31 PREL IMINARY Digital (DTV) RGB or Component Video Connections: See Figure 3-10. Figure 3-10. Digital (DTV) RGB or Component Video Connections HD1 HD2 G/YINPUTS HV R/Pr B/PbG/Y H V R/Pr B/Pb Component Video Pb Pr YVideo S-Video 2 S-Video 1 12 3TRIGGERS HDMI 1 HDMI 2 DTV or Progressive Component (YPbPr) Source Red/Pr Green/Y Blue/Pb Horiz Vert
Installation 32 Runco VX-44d/-55d Owner’s Operating Manual PREL IMINARY Analog (Computer) RGB Connections: See Figure 3-11. Figure 3-11. Analog RGB Connections HD1 HD2 G/YINPUTS HV R/Pr B/PbG/Y H V R/Pr B/Pb Component Video Pb PrY Video S-Video 2S-Video 1 12 3TRIGGERS HDMI 1 HDMI 2 Personal Computer Red Green Blue Horiz Vert
Installation Runco VX-44d/-55d Owner’s Operating Manual 33 PREL IMINARY Composite/S-Video/Component Video Connections: See Figure 3-12. Figure 3-12. Composite, S-Video and Component Video Connections HD1 HD2 G/YINPUTS HV R/Pr B/PbG/Y H V R/Pr B/Pb Component Video Pb PrY Video S-Video 2S-Video 1 12 3TRIGGERS HDMI 1 HDMI 2 DVD Player, VCR, Satellite Receiver, Laser Disc etc. Pb Pr Y
Installation 34 Runco VX-44d/-55d Owner’s Operating Manual PREL IMINARY RS-232 Controller Connection Use a standard, 9-pin RS-232 cable to connect a PC or home theater control/automation system (if present) to the RS-232 Control port on the DHD Controller; see Figure 3-13. For more information about using this connection, refer to Serial Communications on page 83. Figure 3-13. RS-232 Control System Connection Connecting 12-Volt Trigger Outputs to External Theater Equipment If your VX-44d/-55d is equipped with a CineWide with AutoScope system, connect the AutoScope lens motor to a 12-volt trigger output on the DHD Controller; see Figure 3-14. Similarly connect other 12-volt trigger-activated equipment (such as retractable screens or screen masks) to the other trigger outputs. ➤ Pb Pr Y Video3 IR RS-232 Control S-Video 1 S-Video 2 12 TRIGGERS RS-232 Out Component Video12345 7896 to Automation/ Control System or PC 2 Transmit Data 3 Receive Data 5 Ground (none of the other pins are used) ➤
Installation Runco VX-44d/-55d Owner’s Operating Manual 35 PREL IMINARY Figure 3-14. Connecting 12-Volt Trigger Outputs Connecting an External IR Receiver to the DHD Controller If infrared signals from the remote control cannot reach the DHD Controller due to excessive distance or obstructions such as walls or cabinet doors, you can connect an external IR receiver to the DHD Controller to extend the range of the remote control. See Figure 3-15. Figure 3-15. External IR Receiver Connection Tip = +12V Sleeve = Ground Pb Pr Y Video3 IR RS-232 Control S-Video 1 S-Video 2 HD1 HD212 R/Pr G/Y B/Pb R/Pr G/Y B/Pb H V DVI 1 DVI 2 DVI Out H/V V H R/Pr G/Y B/PbHVTRIGGERS RS-232 OutCAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER- SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE CENTER. AV I S : RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR CAUTIONRISK OF ELECTRIC SHOCK DO NOT OPEN! WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. 100-230VAC 50-60 Hz, 165 Watts Max OUTPUTSINPUTS SYSTEM CONTROL INTERFACE Component Video SDI Option Serial No Video Processor / ControllerModel Runco International Union City, CA Made In USA DHD Controller Rear Panel AutoScope Lens Motor (Rear) 3.5-mm mini plug AC Input Power Switch Retractable Screen or other 12-volt trigger-activated device Video3 IR RS-232 Control S-Video 1 S-Video 2 12 TRIGGERS RS-232 OutCAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER- SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE CENTER. AV I S : RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR CAUTIONRISK OF ELECTRIC SHOCK DO NOT OPEN! WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. 100-230VAC 50-60 Hz, 165 Watts Max SYSTEM CONTROL INTERFACE Made In USA DHD Controller Rear Panel Ring = +5V Tip = IR Input Sleeve = Ground (3.5-mm mini phono plug)IR Receiver Remote Control
Installation 36 Runco VX-44d/-55d Owner’s Operating Manual PREL IMINARY Connecting to AC PowerThe VX-44d/-55d system includes two (2) AC power cords (one each for the DHD Controller and projector). DHD Controller: Plug the female end of one power cord into the AC receptacle on the rear of the DHD Controller. Connect the other end to your AC power source (100 to 240 VAC). Projector: Similarly connect the VX-44d/-55d to a nearby AC outlet. The input voltage to a VX-44d must be between 100 and 240 VAC. The input voltage to a VX-55d must be between 200 and 240 VAC. The LED status window displays an active pattern of segments to indicate the projector is changing its state from powered down to powered up. “--” appears in the display when the projector is ready to be turned on. AutoScope Lens Motor: With AutoScope-equipped projectors, a third power cord is provided for the lens motor. Plug the female end of the AC power cord into the AC receptacle on the rear of the lens motor assembly. Connect the other end to a 110 VAC power source. When an external IR receiver is connected to the wired IR input, the built-in IR sensor on the DHD Controller is disabled. Note ➤ The input voltage to the AutoScope lens motor must be between 100 and 120 VAC. Do not connect the AutoScope lens motor to a 200-240 VAC power source! Caution
Installation Runco VX-44d/-55d Owner’s Operating Manual 37 PREL IMINARY 3.8 Turning on the Power 1. Turn on your source components. 2. Turn on the main power switch at the rear of the DHD Controller. 3. If this is an AutoScope-equipped projector, turn on the main power switch at the rear of the AutoScope lens motor. The lens motor power switch is located next to the AC input (see Figure 3-14). 4. Press the ON button on the remote control – or the POWER button on the DHD Controller front panel – to turn on the system. The vacuum fluorescent display on the DHD Controller front panel briefly displays “Starting Display.” The LED status window at the rear of the projector displays an active pattern of segments to indicate that it is changing its state from “standby” to “on.” 5. When the projector has completed its initialization and is ready for use, “On” appears in the projector LED status window. The fluorescent display on the DHD Controller indicates the active source, signal format (NTSC or PAL), input resolution and aspect ratio; for example: Component SD NTSC 480i Anamorphic Vx44/55 Current SourceFormat Input Resolution Aspect Ratio
Installation 38 Runco VX-44d/-55d Owner’s Operating Manual PREL IMINARY 3.9 Adjusting the Picture Orientation By default, the VX-44d/-55d is configured for a “floor/front” installation, in which the projector is installed upright and in front of the screen. If it is installed behind the screen and/or mounted on a ceiling, you must change the picture orientation. To do this: 1. Select an input OTHER THAN HDMI 1 or HDMI 2 on the DHD Controller. 2. On the DHD Controller, press MENU and enter the Service Menu passcode. 3. Select Service from the Main Menu. 4. Select Display Device from the Service Menu. 5. Select Configure from the Display Device menu, then select Installation. 6. Choose Floor/Rear, Ceiling/Front or Ceiling/Rear, to match the installation method. 3.10 Primary Lens Adjustments To access the motorized primary lens controls: 1. On the DHD Controller, press MENU and enter the Service Menu passcode. 2. Select Service from the Main Menu. 3. Select Display Device from the Service Menu. 4. Select Configure from the Display Device menu, then select Lens. The Lens menu gives you a great deal of control over the picture size, position and focus: FocusTo focus the projected image, use the cursor buttons to highlight “In” or “Out.” Then, press and hold the ENTER button. ZoomTo make the picture smaller (zoom out), use the cursor buttons to highlight the minus sign (-). Then, press and hold the ENTER button. To enlarge the picture (zoom in), use the cursor buttons to highlight the plus sign (+). Then, press and hold the ENTER button. Vertical and Horizontal Lens Shift To change the lens position, use the cursor buttons to highlight “Left,” “Right,” “Up” or “Down” in the Lens menu. Then, press and hold the ENTER button to shift the lens in that direction. ➤ ➤ ➤