    							Operation
    Runco VX-2ix Owner’s Operating Manual 29 
    Figure 4-1. VX-2ix OSD Menu Structure
    Calibration
    ISF Night - Display ColorGain
    Offset
    Gamma
    Lamp Power
    Color Temp 
    ISF Night - Input ImageBrightness
    Contrast
    Color
    Tint
    Sharpness
    ISF Night - Input ColorGain
    Offset
    Chroma Delay
    Phase
    Noise Filter
    ISF Day - Display ColorGain
    Offset
    Gamma
    Lamp Power
    Color Temp
    ISF Day - Input ImageBrightness
    Contrast
    Color
    Tint
    Sharpness
    ISF Day - Input ColorGain
    Offset
    Chroma Delay
    Phase
    Noise Filter
    Save ISF Settings Back / Confirm
    Output ShiftLeft/Right
    Up/Down
    Width
    Height
    Save
    Splash ConfigureOwner Name
    ISF Calibrated
    ISF Other
    OSD Position
    Service
    Test VideoGrey Bars 1
    Grey Bars 2
    Color Bars 1
    Color Bars 2
    Input Names Rename, Restore or Save
    Remote ControlPrimary
    Secondary
    Display DeviceInstallationPicture Orientation
    Lamp Hours (View/Reset)
    LensFocus
    Zoom
    Shift
    DiagnosticsRed Only
    Green Only
    Blue Only
    75 IRE Color Bars
    100 IRE Color Bars
    Horiz. Grey Ramp
    Vert. Grey Ramp
    Checkerboard
    Alignment Grid
    HD FormatHD/RGB 1
    Auto, RGB or YUV
    HD/RGB 2
    ADC Bandwidth Auto, 75 MHz, 150 MHz or 300 MHz
    YPbPr Input Resolution Auto, 480i/p, 576i/p, 720p or 1080i
    Triggers 1 / 2 / 3 / Save
    MiscellaneousLanguage (currently, English only)
    Menu Mode
    Timeout
    Side Bar Color
    Film Mode (SD src. only)
    Resolution800x600 ... 1400x1050 
    480i ... 720p ... 1080i 
    System Reset
    Restore Saved Settings
    Note: Virtualwide 2.35 is 
    available only on VX-2ix 
    projectors equipped with the 
    CineWide option (secondary 
    anamorphic lens). 
    Input Source
    Composite
    S-Video 1
    S-Video 2
    Component SD
    HD/RGB 1
    HD/RGB 2
    DVI 1
    DVI 2
    Aspect Ratio
    Anamorphic
    Standard 4:3
    Letterbox
    VirtualWide
    Cinema
    Virtualwide 2.35
    Picture
    Brightness
    Contrast
    Color
    Tint
    Sharpness
    Input Position
    Left/Right
    Up/Down
    Width
    Height
    Overscan
    ISF Presets
    Recall ISF Night
    Recall ISF Day
    Recall/Save Custom 1
    Recall/Save Custom 2
    Reset Custom 1 & 2 to Factory Default
    Information(read-only)Serial Number
    Hardware
    Firmware
    Date 
    						
    							Operation
    30 Runco VX-2ix Owner’s Operating Manual
    Main Menu The Main Menu is the starting point for accessing all projector functions. 
    (The Calibration and Service menus are hidden and not accessible until you enter a 
    passcode.) 
    Input SourceFrom the Main Menu, select Input Source to choose a video signal source. 
    The active source is indicated by an arrow (>) to its left; in the example at left, Composite 
    is the active source. 
    Aspect RatioTo change the aspect ratio (size and shape) of the projected image, select Aspect Ratio 
    from the Main Menu and press ENTER. Select the appropriate aspect ratio for the type of 
    program material being viewed; refer to 
    Table 4-1. 
    The currently-selected aspect ratio is indicated by a “7” to its left; in the example at left, 
    Anamorphic is selected. 
      
    Runco Video
    Input Source
    Aspect Ratio
    Picture
    Input Position
    ISF Presets
    Information
    Calibration
    Service
    ➤
    Input Source
    >
    Composite
    S-Video 1
    S-Video 2
    Component SD
    HD/RGB 1
    HD/RGB 2
    DVI 1
    DVI 2
    ➤
    Aspect Ratio
    7Anamorphic
    …Standard 4:3
    …Letterbox
    …VirtualWide
    …Cinema
    …Virtualwide 2.35
    ➤
    The aspect ratio selection is automatically saved for each input and 
    resolution.Note 
    						
    							Operation
    Runco VX-2ix Owner’s Operating Manual 31 
    Table 4-1. Aspect Ratio Settings 
    Aspect Ratio
    Remote 
    Control
    Key
    Description
    AnamorphicANASelect Anamorphic to view 16:9 
    DVDs and HDTV programs in 
    their native aspect ratio. 4:3 
    images are stretched 
    horizontally to fit a 16:9 screen. 
    Standard 4:34X3Standard 4:3 scales the input 
    signal to fit in the center of the 
    16:9 screen. 4:3 is the aspect 
    ratio used by computer 
    monitors, standard television 
    programming and most VHS 
    video cassettes. 
    LetterboxLET
    BOXIn Letterbox mode, the image is 
    stretched vertically; the top and 
    bottom portions are “blanked 
    off.” Letterbox is best suited for 
    viewing LaserDisc movies or 
    non-anamorphic DVDs on a 4:3 
    screen.
    VirtualWideV-WIDEVirtualWide scales a 4:3 image 
    NON-linearly (more on the sides 
    than in the center) to fit a 16:9 
    screen. 
    4:3 Image on
    16:9 Screen 16:9 Image on
    16:9 Screen
    Active Image
    Area (4:3)
    Letterbox Image on
    16:9 Screen 
    						
    							Operation
    32 Runco VX-2ix Owner’s Operating Manual
    CinemaCINEMASelect Cinema to view 2.35 
    source material in its native 
    aspect ratio.
    With a 16:9 screen and a 
    non-CineWide projector (no 
    anamorphic lens), the upper and 
    lower portions of the screen are 
    masked, but the geometry of the 
    active image area is unchanged.
    With a 2.35:1 screen and a 
    CineWide-equipped projector, 
    the VX-2ix vertically stretches 
    the 2.35 image so that the active 
    image area fills the 16:9 chip 
    surface, eliminating the black 
    bars. The secondary 
    anamorphic lens then stretches 
    the image back to 2.35:1. 
    Virtualwide 2.35SVCA 16:9 image is scaled 
    NON-linearly (more on the sides 
    than in the center) to fit a 2.35:1 
    screen. 
    Virtualwide 2.35 is available only 
    on CineWide-equipped VX-2ix 
    projectors. 
    Table 4-1. Aspect Ratio Settings (continued)
    Aspect RatioRemote 
    Control
    KeyDescription
    2.35:1 Image on
    16:9 Screen
    (without CineWide)
    2.35:1 Image on
    2.35:1 Screen
    (with CineWide)
    16:9 Image on
    2.35:1 Screen with
    VirtualWide 2.35
    16:9 Image on
    2.35:1 Screen16:9 Image on
    2.35:1 Screen 
    						
    							Operation
    Runco VX-2ix Owner’s Operating Manual 33 
    Picture Use the controls in the Picture Menu to calibrate your VX-2ix for optimum picture quality.
    The VX-2ix has been designed to incorporate setup and calibration standards established 
    by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted, 
    industry-recognized standards for optimal video performance and has implemented a 
    training program for technicians and installers to use these standards to obtain optimal 
    picture quality from Runco video display devices. Accordingly, Runco recommends that 
    setup and calibration be performed by an ISF certified installation technician.
    All signal types require separate processing. Therefore, you need to calibrate each input 
    separately. 
    Although it may be possible to obtain satisfactory picture quality using the naked eye and 
    regular program material, Runco recommends using the following calibration tools for best 
    results: 
     External test pattern source – Ovation Multimedia, Digital Video Essentials or AVIA test 
    DVD or equivalent.
     A blue filter (provided with many test DVDs), for color level and tint adjustments.
    Connect your test pattern source to the input that you are calibrating and proceed as 
    follows. Perform the adjustments in the order listed here.
    Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an 
    acronym for “Picture Line-Up Generation Equipment.”) 
    Figure 4-2 shows a typical PLUGE 
    pattern.
    Figure 4-2. Typical PLUGE Pattern for Adjusting Brightness
    Picture
    Brightness
    Contrast
    Color
    Tint
    Sharpness
    When you change a picture quality setting, save the change to a 
    preset afterwards. Otherwise, the change will be lost when a 
    different input is selected. (Picture quality settings are saved for 
    each input separately.) For information about saving settings, refer 
    to 
    ISF Presets on page 37. 
    Note
    Below Black
    Above Black 
    						
    							Operation
    34 Runco VX-2ix Owner’s Operating Manual
    PLUGE patterns vary but generally consist of some combination of black, white and gray 
    areas against a black background. The example above includes two vertical bars and four 
    shaded boxes.
    Select Brightness from the Picture menu and press ENTER. Adjust the brightness so that:
     The darkest black bars disappear into the background. 
     The dark gray areas are barely visible.
     The lighter gray areas are clearly visible.
     The white areas are a comfortable level of true white.
     The image contains only black, gray and white (no color).
    Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the 
    one shown in 
    Figure 4-3. 
    Figure 4-3. Typical Gray Bar Pattern for Adjusting Contrast
    Select Contrast and press ENTER. Adjust the contrast to a point just below which the 
    white rectangle starts to increase in size.
    Brightness and contrast controls are interactive. A change to one 
    may require a subtle change to the other in order to achieve the 
    optimum setting. Note 
    						
    							Operation
    Runco VX-2ix Owner’s Operating Manual 35 
    Color Saturation: On your external test pattern source, select a color bar pattern like the 
    one shown in 
    Figure 4-4. 
    Figure 4-4. Typical Color Bar Pattern for Adjusting Color Saturation and Tint
    Select Color and press ENTER. While looking at the color bar pattern through a blue filter, 
    adjust the color saturation level until the outermost (gray and blue) color bars appear to be 
    a single shade of blue: 
    Tint: Tint or “hue” is essentially the ratio of red to green in the color portion of the image. 
    When tint is decreased, the image appears redder; when it is increased the image 
    appears greener. To set the tint, select Tint and press ENTER. While looking at the color 
    bar pattern through a blue filter, adjust the tint level until the cyan and magenta color bars 
    (on either side of the green bar) appear to be a single shade of blue. 
    Like the brightness and contrast controls, the color and tint controls 
    are interactive. A change to one may require a subtle change to the 
    other in order to achieve the optimum setting. 
    gray
    yellow
    cyan
    green
    magenta
    red
    blue
    gray
    yellow
    cyan
    green
    magenta
    red
    blue
    Note 
    						
    							Operation
    36 Runco VX-2ix Owner’s Operating Manual
    Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust 
    sharpness, select Sharpness from the Picture menu and press ENTER. On your external 
    test pattern source, select a pattern like the one shown in 
    Figure 4-5. Adjust as needed, 
    looking for white edges around the transitions from black to gray and differently-sized lines 
    in the “sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate 
    them. 
    Figure 4-5. Typical Test Pattern for Adjusting Sharpness
    Input PositionUse the controls in the Input Position Menu to fine-tune the aspect ratio and image 
    position for the current source.
    Left/Right: Select Left/Right from the Input Position menu to shift the projected image 
    horizontally. Use the right or up cursor button to shift the image to the right; use the left or 
    down button to shift it to the left.
    Up/Down: Select Up/Down from the Input Position menu to shift the projected image 
    vertically. Use the right or up cursor button to shift the image upward; use the left or down 
    button to shift it downward.
    Width: Select Width from the Input Position menu to change the projected image width. 
    Use the right or up cursor button to increase the width; use the left or down button to 
    decrease it.
    Height: Select Height from the Input Position menu to change the projected image 
    height. Use the right or up cursor button to increase the height; use the left or down 
    button to decrease it.
    Input Position
    Left/Right
    Up/Down
    Width
    Height
    Overscan
    ➤
    The input position settings are automatically saved for each input 
    and resolution.Note 
    						
    							Operation
    Runco VX-2ix Owner’s Operating Manual 37 
    Overscan: Image Overscan pushes the outside edge of the active picture area of the 
    video signal out beyond the edge of the display area. 
    Some television programs are produced based on the assumption that older television 
    sets may not display the outer edges of the broadcast picture area. Overscan effectively 
    trims away these inactive, outer edges and enlarges the remaining portion of the image to 
    fill the display area.
    Select from 1% to 10% of Overscan, as desired.
    For HDTV, DVDs and other video sources, Overscan is generally not necessary or 
    desirable.
    ISF PresetsFor each input, the VX-2ix lets you save image quality settings as presets that you can 
    recall at a later time. You can create up to four presets per input and resolution. Use the 
    ISF Presets menu to recall saved image presets, or to save image settings in the 
    “Custom
     1” or “Custom 2” memory location. The currently-selected preset is indicated by 
    a “
    7” to its left; in the example shown here, ISF Night is selected.
    You should save changes to any of the following settings to a preset; otherwise they will 
    be lost when a new input source or resolution is selected:
     Brightness
    Contrast
     Color saturation
    Tint
     Sharpness
    To reset the Custom 1 and Custom 2 image presets to their factory defaults, select 
    Factory Default and press ENTER. 
    InformationSelect Information from the Main Menu to see information that uniquely identifies your 
    projector: its serial number, the installed hardware and firmware versions and the firmware 
    version build date. Should you ever need to contact Runco Technical Support, this 
    information will help them answer your questions or resolve product performance issues. 
    ISF Presets
    7ISF Night
    …ISF Day
    …Custom 1      Save
    …Custom 2      Save
    Factory Default
    Information
    Serial Number
    Hardware 0
    Firmware 0002.012A
    Date Mar 29 2006 
    						
    							Operation
    38 Runco VX-2ix Owner’s Operating Manual
    CalibrationUse the Calibration menu to perform advanced picture quality adjustments. This menu 
    should be used by ISF-certified technicians only. 
    To recall the ISF Night or ISF Day settings, select “ISF Night” or “ISF Day” from the ISF 
    Presets menu (
    page 37). 
    ISF Night - Display Color: Use the Display Color settings to adjust the color balance at 
    the projector output. These settings are saved independently for each input.
    Gain: Use the Gain controls to correct color imbalances in the bright areas of the 
    image. A good way to do this is to use a test pattern consisting mostly of solid white 
    areas, such as an 80 IRE “window” pattern. If the white areas contain traces of red, 
    green or blue, decrease the Gain for that color.
    Offset: Use the Offset controls in the White Balance sub-menu to correct color 
    imbalances in the dark areas of the image. A good way to do this is to use a test 
    pattern consisting mostly of dark gray areas, such as a 30 IRE “window” pattern. If the 
    gray areas contain traces of red, green or blue, decrease the Offset for that color.
     Gamma: “Gamma” is a global setting that determines how gray shades are displayed 
    between minimum input (black) and maximum input (white) for all signals. A good 
    gamma setting helps to optimize blacks and whites while ensuring smooth transitions 
    for the “in-between” values utilized in other grays. Unlike “Brightness” and “Contrast” 
    controls, the overall tone of your images can be lightened or darkened without 
    changing the extremes and all images will be more vibrant while still showing good 
    detail in dark areas. 
    In all but the most unusual situations, the appropriate “Color Temp” selection (see 
    below) will produce accurate colors and a satisfying contrast level. However, it is 
    sometimes necessary to adjust the red, blue and green gamma curves individually. To 
    do this, select Gamma from the Display Color sub-menu and use the left- and 
    right-arrow buttons to manipulate the on-screen slidebars. 
    Lamp Power: Select Lamp Power from the Display Color Menu to adjust the lamp 
    output level. You can choose to run the lamp as bright as possible (“1”; this is the 
    default setting) or you can choose the lower setting (“0”). Generally, lower lamp output 
    can prolong the life of the lamp, but decreases brightness. 
     Color Temp: Select Color Temp from the Display Color menu to adjust the color 
    temperature. The default setting is appropriate for most situations. Higher settings 
    produce a “bluer” picture.
    ISF Night - Input Image: The Input Image controls are similar to those in the Picture 
    menu, but are accessible only by entering the Calibration menu passcode. This makes it 
    possible to restore the picture quality settings to what they were when the projector was 
    installed, simply by recalling the “ISF Night” preset. 
    Calibration
    ISF Night
        Display Color
        Input Image
        Input Color
    ISF Day
        Display Color
        Input Image
        Input Color
    Save ISF Settings
    Output Shift
    Splash Configure
    OSD Position
    ➤
    You must enter a passcode to access the Calibration menu. Note 
    						
    All Runco manuals Comments (0)

    Related Manuals for Runco Vx 2ix Projector User Manual