Runco Vx 2dcx Projector User Manual
Have a look at the manual Runco Vx 2dcx Projector User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 123 Runco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Maintenance and Troubleshooting Runco VX-2cx/VX-2dcx Owner’s Operating Manual 59 PREL IMINARY 5.3 Troubleshooting Tips Table 5-1 provides some general guidelines for troubleshooting problems you may encounter with the VX-2. If you encounter an issue not described here, please contact Runco Technical Support. Table 5-1. Troubleshooting Chart SymptomPossible Cause(s)Solution The projector does not turn on after initial installation. The power LED on the front of the DHD Controller lights red after you press the power button. The DHD Controller is connected to the VX-2 incorrectly or not at all. The VX-2 is not plugged in or the AC outlet is not active. Verify the DVI cable connection from the DHD Controller to the VX-2. Ensure that the VX-2 is plugged in and that the AC outlet is active. The projector and DHD Con- troller are both on, but there is no video image on-screen. Incorrect source selection. Source component is not turned on. Select the correct source. Turn on the source. A projected image from a DVD is split or otherwise scrambled. DVD player is connected to the Component input and set to progressive scan mode. Turn off progressive scan on the DVD player. Or, connect the DVD player to the HD1 or HD2 input. Image is too bright and/or lacks definition in the bright areas of the image. Contrast is set too high. Lower the contrast setting. Image appears “washed out” and/or dark areas appear too bright. Brightness is set too high. Lower the brightness setting. Colors in the image are swapped; for example, reds appear blue or vice versa. The Red/Pr, Green/Y or Blue/Pb outputs from the source are connected to the wrong inputs on the DHD Controller. Ensure that the source outputs are connected to the correct DHD Controller input. Image geometry is incorrect. Incorrect aspect ratio selection. Select the aspect ratio that best matches the source image and screen size (refer to Table 4-1). The projector will not turn back on after it was powered down, or the image disap - pears during operation. The projector will not turn on for two minutes after power-down, to protect the lamp. The lamp has failed. Wait two minutes until the LED at the front of the DHD Controller turns red. Replace the lamp.
Maintenance and Troubleshooting 60 Runco VX-2cx/VX-2dcx Owner’s Operating Manual PREL IMINARY Notes:
Runco VX-2cx/VX-2dcx Owner’s Operating Manual 61 PREL IMINARY 6.1 RS-232 Connection and Port Configuration To interface the DHD Controller with a home theater automation/control system or a PC running terminal emulation software, connect it to your control system or PC as shown in Figure 3-11. Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit and no flow control. Set the baud rate to 19200, to match that of the DHD Controller RS-232 port. 6.2 Serial Command Syntax Serial commands to the DHD Controller take the following form: Commands are not case-sensitive. For a single command that takes no parameters, type the command followed by a carriage return; for example, to set the aspect ratio to Letterbox, type LETTERBOX . For a single command that takes a parameter, type the command, a space or a comma and the desired value followed by a carriage return; for example, to set the brightness to -10, type BRIGHTNESS -10 or BRIGHTNESS,-10 . You can also send a string of multiple commands on a single line, separated by commas. For example, COMPOSITE,BRIGHTNESS 100,ANAMORPHIC switches to the Composite video input, sets the brightness to 100 and sets the aspect ratio to Anamorphic. Command strings can be up to 255 characters long. Table 6-1 lists the RS-232 command set. The “Parameter (min/max)” column shows the valid parameter ranges, or “NA” for commands that take no parameters. When you enter a valid command, the DHD Controller executes it and acknowledges it with a plus sign on the command line (+ >). When you enter an invalid command – one that is misspelled or followed by values outside the valid range for that command – the DHD Controller ignores it and returns a minus sign (- >). 6. Serial Communications Avoid combining the ON or POWER 1 commands with other commands on a single line. After sending ON or POWER 1, allow at least 15 seconds for the DHD Controller to power up. Once it does, it will accept and properly execute multiple serial commands. Table 6-1. Serial Commands CommandParameter (min/max)Value Stored?Description Power On/Off Commands OFFNANATurns projector off ONNANATurns projector on POWER0/1NATurns projector on and off POWER?NANAReturns power status Note
Serial Communications 62 Runco VX-2cx/VX-2dcx Owner’s Operating Manual PREL IMINARY Input Selection Commands COMPONENTNAYESSelects the Component input COMPOSITENAYESSelects the Composite video input DVI1NAYESSelects the DVI 1 input DVI2NAYESSelects the DVI 2 input HD1NA YESSelects the RGB HD 1 input HD2NA YESSelects the RGB HD 2 input INPUT?NANAReturns active input SVIDEO1NAYESSelects the S-Video 1 input SVIDEO2NAYESSelects the S-Video 2 input Aspect Ratio Commands ANAMORPHICNAYESSelects the Anamorphic aspect ratio ASPECT?NANAReturns current aspect ratio ASPECTIN?NANAReturns the input source aspect ratio ASPECTOUT?NANAReturns output screen size CINEMANAYESSelects the Cinema aspect ratio LETTERBOXNAYESSelects the Letterbox aspect ratio OUT169NAYESSets the output screen to 1.78:1 (16:9) OUT235NAYESSets the output screen to 2.35:1 STANDARDNAYESSelects the Standard (4:3) aspect ratio VIRTUALWIDENAYESSelects the VirtualWide aspect ratio VIRTUAL235NAYESSelects the Virtualwide 2.35 aspect ratio Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
Serial Communications Runco VX-2cx/VX-2dcx Owner’s Operating Manual 63 PREL IMINARY Picture Adjust Commands BRIGHTNESS-100/100YESSets a value for brightness BRIGHTNESS?NANAReturns brightness setting value CHROMADELAY-12/12YESSets a value for input color chroma delay CHROMADELAY?NANAReturns input color chroma delay setting COLOR-100/100YESSets a value for color COLOR?NANAReturns color setting value CONTRAST-100/100YESSets a value for contrast CONTRAST?NANAReturns contrast setting value FILMMODE0/1YESSets Film Mode off (0) or on (1) FILMMODE?NANAReturns Film Mode setting (0 = off; 1 = on) FILTER0/15YESSets a value for input color noise filter FILTER?NANAReturns input color noise filter setting PHASE0/3YESAdjusts phase PHASE?NANAReturns phase setting value SHARPNESS-6/6YESSets a value for sharpness SHARPNESS?NANAReturns sharpness setting value TINT-100/100YESSets a value for tint TINT?NANAReturns tint setting value Image Preset Commands CUSTOM1NAYESLoads “Custom 1” image preset CUSTOM2NAYESLoads “Custom 2” image preset DAYNAYESLoads “ISF Day” image preset NIGHTNAYESLoads “ISF Night” image preset PRESET?NANAReturns currently-selected preset (ISF Day, ISF Night, Custom 1 or Custom 2) Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
Serial Communications 64 Runco VX-2cx/VX-2dcx Owner’s Operating Manual PREL IMINARY Input Position Commands IHEIGHT-100/100YESSets the value for input height IHEIGHT?NANAReturns input height value IHPOS-100/100YESSets a value for horizontal input position IHPOS?NANAReturns input horizontal position value IVPOS-100/100YESSets a value for vertical input position IVPOS?NANAReturns input vertical position value IWIDTH-100/100YESSets the value for input width IWIDTH?NANAReturns input horizontal width value OVERSCAN 0/10YESSets the overscan percentage OVERSCAN?NANAReturns overscan percentage Output Shift Commands OHEIGHT-100/100YESSets the value for output height OHEIGHT?NANAReturns output height value OHPOS-100/100YESSets the value for output horizontal position OHPOS?NANAReturns output horizontal position value OVPOS-100/100YESSets the value for output vertical position OVPOS?NANAReturns output vertical position value OWIDTH-100/100YESSets the value for output width OWIDTH?NANAReturns output horizontal width value Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
Serial Communications Runco VX-2cx/VX-2dcx Owner’s Operating Manual 65 PREL IMINARY Miscellaneous Commands BKGND-100/100YESSets the background color for letterbox or 4:3 aspect ratio (-100 = black; 100 = white) BKGND?NANAReturns background setting value DATE?NANAReturns product manufacture date HDINPUTRESNAYESSets YPbPr input resolution and refresh rate for HD1/HD2, as follows: 0 = 480i 1 = 480p 2 = 576i 3 = 576p 4 = 720p / 60 Hz 5 = 1080i / 60 Hz 6 = 720p / 50 Hz 7 = 1080i / 25 Hz Any other value = Auto HWVER?NANAReturns hardware version number INRES?NANAReturns input resolution LENS10 or 4YESSet primary lens configuration: 0 = No anamorphic lens present 4 = Anamorphic lens present LENS1?NANAReturns Lens 1 configuration LENS20 or 8YESSet anamorphic lens type: 0 = Fixed CineWide 8 = CineWide with AutoScope LENS2?NANAReturns Lens 2 configuration OUTRES0/5YESSets output resolution, as follows: 0 = 480i 1 = 576i 2 = 480p 3 = 576p 4 = 720p 5 = 1080i OUTRES?NANAReturns output resolution SWVER?NANAReturns software version number TRIGGER1/3YESAssigns trigger to currently-selected aspect ratio Table 6-1. Serial Commands (continued) CommandParameter (min/max)Value Stored?Description
Serial Communications 66 Runco VX-2cx/VX-2dcx Owner’s Operating Manual PREL IMINARY Notes:
Runco VX-2cx/VX-2dcx Owner’s Operating Manual 67 PREL IMINARY 7.1 VX-2 Specifications Table 7-1 lists the VX-2 specifications. 7. Specifications Table 7-1. VX-2 Specifications Projector Type:Digital Light Processing (DLP), 3-chip, 16:9 SuperOnyx DMD Native Resolution:1280 x 720 (16:9) Aspect Ratios:Refer to Table 7-2 Video Standards:Refer to Table 7-2 DTV Compatibility:480p, 720p, 1080i THX recommends the use of 720p source material for optimal performance with this product. Scan Frequency:Horizontal: 15 - 100 kHz Vertical: 28 - 78 Hz Picture Size (16:9 Screen):Recommended Width: 72 - 120 in. Maximum Width: 250 in. Throw Distance (Factor x Screen Width):VX-2cx: Refer to Table 3-3 VX-2dcx: Refer to Table 3-4 Horizontal and Vertical Offset:VX-2cx/Proteus A: None VX-2cx/Proteus B, C, D, E, F: Horizontal: 10% of screen width left or right Vertical: 80% of screen height down; 0% up VX-2dcx: Refer to Table 3-5 Lamp:275 Watts Estimated Lamp Life: 2000 hours Inputs: (1) DVI with HDCP (from DHD Controller) Controls:Built-in keypad
Specifications 68 Runco VX-2cx/VX-2dcx Owner’s Operating Manual PRELI MINARY Brightness and Contrast: Cinema Standards Measurement System (CSMS) Specifications - Brightness: 52.1 foot-Lamberts (fL) (VX-2cx); 57.6 foot-Lamberts (fL) (VX-2dcx) - Contrast Ratio: 271:1 (VX-2cx); 304:1 (VX-2dcx) These measurements are taken from the projector in a controlled, home theater environment. All measurements are made to ANSI/NAPM IT7.228-1997 specifications using the Photo Research PR-650 SpectraColorimeter and Minolta LS-100 Luminance Meter, Video Essentials test DVD and a 1.3 gain, 72-inch wide screen. The projector is calibrated to a color temperature of 6,500K and has a minimum of 150 hours of usage. The foot-Lambert (fL) is the unit of measurement used in commercial movie theaters to express image brightness at the screen surface. The Society of Motion Picture and Television Engineers (SMPTE) specifies 16 fL as the target image brightness for film-based projectors using an open gate (without film in the projector). More importantly, today SMPTE specifies 12 fL as the target image brightness in Digital Cinema theaters. The foot-Lambert measurement is dependent on screen size, screen gain and projector light output. Home Theater Calibration Specifications - Light Output: 1227 ANSI Lumens (VX-2cx); 1389 ANSI Lumens (VX-2dcx) - Contrast Ratio: 271:1 (VX-2cx); 304:1 (VX-2dcx) These specifications are obtained by calibrating the projector as described above for CSMS measurements. Industry-Standard Specifications - Light Output: 2500 ANSI Lumens (VX-2cx); 2800 ANSI Lumens (VX-2dcx) - Contrast Ratio: 3100:1 (VX-2cx); 3500:1 (VX-2dcx) These are typical projector brightness and contrast specifications found in most companies’ sales literature. Runco includes these measurements in its literature to allow for direct comparison with other manufacturers’ projectors. These measurements are typically taken at 9,000K to 13,000K to get expected performance data when the projector is used in professional, commercial and industrial displays. Power Requirements: 100 to 240 VAC (auto-sensing), 50/60 Hz, 510 Watts Operating Environment:41°F to 95°F (5°C to 35°C), 0% to 90% humidity (non-condensing) Dimensions:VX-2cx: See Figure 7-1 VX-2dcx: See Figure 7-2 Weight (without lens):VX-2cx: 81 lbs. (36.74 kg) VX-2dcx: 83 lbs. (37.65 kg) Regulatory Approvals:Complies with FCC, CE C-Tick Limited Warranty: Projector: Two (2) years parts and labor from the date of delivery to the end user. Lamp: 1000 hours or six (6) months, whichever comes first. Specifications are subject to change without notice. Table 7-1. VX-2 Specifications (continued)