Home > Runco > Projector > Runco Rs 1100 Ultra Projector User Manual

Runco Rs 1100 Ultra Projector User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Runco Rs 1100 Ultra Projector User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 123 Runco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Installation
    Runco RS-1100 Series Owner’s Operating Manual 29 
    PREL
    IMINARY
    RS-232 Controller 
    Connection 
    Connect a PC or home theater control/automation system (if present) to the RS-232 port 
    on the RS-1100; see 
    Figure 3-13. Use a standard, 4-wire RJ-11 telephone cable, wired 
    straight-through.
    For more information about using this connection, refer to Serial Communications on 
    page 69.
    Figure 3-13. RS-232 Control System Connection
    S-VID /S-VID
    123457896
    D-Sub 9-pin female RJ-11 MaleRJ-11 to
    D-Sub 9-pin Adapter
    (not included)
    1
    2
    3
    4
    Ye l l o w
    Ye l l o w
    RedRedBlackGreen
    Green
    Black
    RS-232 Adapter Wiring
    D-Sub 9-pin female 4-pin RJ-11 Function
    2 2 Transmit Data
    3 3 Receive Data
    5 1, 4 Ground
    1, 4, 6, 7, 8, 9 -- Not Connected 
    						
    							Installation
    30 Runco RS-1100 Series Owner’s Operating Manual
    PREL
    IMINARY
    Connecting 12-Volt 
    Trigger Output to External 
    Theater Equipment
    If your RS-1100 is equipped with a CineWide with AutoScope system, use the cable 
    supplied with the AutoScope Lens Motor to connect the motor to the 12-volt trigger 
    output as shown in 
    Figure 3-14. 
    Figure 3-14. Connecting the 12-Volt Trigger Output to the AutoScope Lens Motor
    If your home theater contains a retractable screen, screen mask or other 12-volt 
    trigger-activated equipment, use the cable supplied with the RS-1100 to connect it to the 
    12-volt trigger output as shown in 
    Figure 3-15. 
    Figure 3-15. Connecting the 12-Volt Trigger Output to Other Equipment
    ➤
    S-VID /S-VID
    3.5-mm
    mini plug
    to AutoScope
    Lens Motor
    S-VID /S-VID
    to other,
    12-volt
    trigger-activated equipment
    (screen, screen mask etc.)Red = +12V (Tip) Black = Ground (Sleeve)3.5-mm
    mini plug 
    						
    							Installation
    Runco RS-1100 Series Owner’s Operating Manual 31 
    PREL
    IMINARY
    Connecting to AC PowerProjector: The RS-1100 ships 
    with various types of AC power 
    cords. Choose the one that is 
    appropriate to your locale. 
    Plug the female end of the power 
    cord into the AC receptacle on the 
    rear of the projector (AC 100V ~ 
    240V). Then, connect the other end 
    to your AC power source. 
    AutoScope Lens Motor: With AutoScope-equipped projectors, an additional power 
    cord is provided for the lens motor. Plug the female end of the AC power cord into the AC 
    input on the rear of the lens motor assembly. Connect the other end to a 110
     VAC power 
    source. 
    3.7 
    Turning on the Power
    1. Turn on your source components. 
    2. If this is an AutoScope-equipped projector, turn on the main power switch at the rear 
    of the AutoScope lens motor. The lens motor power switch is located next to the AC 
    input (see above). 
    3. Turn on the main power switch at the rear of the projector. The POWER LED lights 
    orange. The LAMP and TEMP LEDs light red briefly, then go out. 
    4. Press the ON button on the remote control to turn on the RS-1100. The POWER LED 
    flashes orange to indicate that it is warming up. 
    5. When the projector is ready for use, the POWER LED lights green. 
    6. “Searching...” appears on the screen before the RS-1100 identifies the input signal 
    and remains there until a valid signal is detected. 
    7. If an incompatible input signal exceeds the range of the projector, a “No signal 
    supported message appears on the screen. This message remains on the screen 
    until you change the input signal. 
    The input voltage to the AutoScope lens motor must be between 
    100 and 120 VAC. Do not connect the AutoScope lens motor 
    to a 200-240
     VAC power source!
    Power
    switch 
    Caution
    AutoScope Lens Motor (Rear)
    AC Input Power
    Switch
    to 
    110 VAC
    Power 
    						
    							Installation
    32 Runco RS-1100 Series Owner’s Operating Manual
    PREL
    IMINARY
    3.8 
    Changing the OSD 
    Language
    The RS-1100 OSD language is initially set to English, but can also display the menus in 
    French, Spanish, Italian or German. To change the OSD language:
    1. Press MENU.
    2. Select Installation from the Main Menu and press ENTER.
    3. Select Language from the Installation Menu and press ENTER.
    4. Press  or  to highlight the desired language. (The change takes effect 
    immediately.)
    3.9 
    Adjusting the Picture 
    Orientation
    By default, the RS-1100 is configured for a “floor/front” installation, in which the projector 
    is installed upright and in front of the screen. If it is installed behind the screen and/or 
    mounted on a ceiling, you must change the picture orientation. To do this:
    1. Press MENU on the remote control. 
    2. Select Installation from the Main Menu and press ENTER. 
    3. Select Picture Orientation from the Installation Menu and press ENTER.
    4. Choose Floor Rear, Ceiling Front or Ceiling Rear to match the installation method.
    3.10 
    Primary Lens 
    Adjustments
    The RS-1100 gives you a great deal of control over the 
    picture size, position and focus. To access the motorized 
    lens controls, use the FOCUS, ZOOM and LENS buttons 
    on the remote control. 
    FocusTo focus the projected image, press the FOCUS button, then use the left- and right-arrow 
    buttons to adjust the focus. 
    ZoomTo make the picture smaller (zoom out), press the ZOOM button, then use the left-arrow 
    (
      ) button. 
    To enlarge the picture (zoom in), press the ZOOM button, then use the right-arrow (  ) 
    button. 
    Vertical and Horizontal 
    Lens Shift
    Vertical Lens Shift: To shift the projected image vertically, press the LENS button, then 
    use the up and/or down-arrow ( 
    ,  ) buttons. 
    Horizontal Lens Shift (RS-1100 Ultra Only): To shift the projected image horizontally, 
    press the LENS button, then use the right and/or left-arrow buttons. 
    FOCUS   LENSZOOMFOCUSZOOM
    LENS
    ➤
    ➤
    ➤ 
    						
    							Installation
    Runco RS-1100 Series Owner’s Operating Manual 33 
    PREL
    IMINARY
    3.11 
    Installing and 
    Adjusting the 
    CineWide Anamorphic 
    Lens
    If you are installing a CineWide-equipped projector, proceed as follows to install and 
    adjust the anamorphic lens. 
    The standard RS-1100/CineWide uses a prismatic-style anamorphic lens. This type of 
    lens compresses the height of the image (as opposed to stretching the width) to achieve a 
    2.35:1 aspect ratio with a 1.78:1 display device. 
    The RS-1100 Ultra/CineWide and RS-1100 Ultra/CineWide with AutoScope use a 
    cylindrical anamorphic lens with a much larger aperture than the prismatic lens used with 
    the standard RS-1100/CineWide. 
    If you are installing a standard RS-1100/CineWide or RS-1100 Ultra/CineWide, refer to 
    Anamorphic Lens Installation and Adjustment - Standard RS-1100/CineWide or 
    RS-1100 Ultra/CineWide on page 38. If you are installing an RS-1100 Ultra/CineWide 
    with AutoScope, continue with the next section. 
    Anamorphic Lens 
    Installation and 
    Adjustment - RS-1100 
    Ultra/CineWide with 
    AutoScope
    The RS-1100 Ultra Anamorphic lens mount kit consists of everything shown in Figure 
    3-16. Some components shipped with your projector may differ slightly from what is 
    shown in these instructions. 
    Figure 3-16. RS-1100 Ultra Anamorphic Lens Mounting Assembly - Exploded 
    View
    It is extremely important that the primary lens is properly 
    adjusted before you install the anamorphic lens. Ensure that 
    the image from the primary lens is perfectly centered on the 
    screen. Note
    Pitch Adjustment Yoke
    for Lens
    Height/Y Adjustment 
    T-Screw (2)
    and Washer (2)
    Pitch Adjustment 
    T-Screw (2)
    and Washer (2) 
    Anamorphic Lens 
    Holder
    1/4-20 Hex Bolts (2)
    AutoScope Carriage Plate  Yaw/X Adjustment
    Levers (2) and
    Washers (2)2
    3
    4
    6
    7 8
    5
    Anamorphic Lens Mount1 
    						
    							Installation
    34 Runco RS-1100 Series Owner’s Operating Manual
    PREL
    IMINARY
    Attaching Lens Mounting Assembly to Lens Motor Carriage Plate: 
    1. Remove the two Yaw/X Adjustment Levers and 1/4-20 Fiber Washers from the 
    bottom of the lens mounting assembly.
    2. Place the Lens Mounting Assembly on top of the Lens Motor Carriage Plate. Position 
    the bracket so that the long slot at the bottom of the bracket is perpendicular to the 
    corresponding slots on the carriage plate.
    3. Secure the Lens Mounting Assembly to the plate with the Yaw/X Adjustment Levers 
    and Washers that you removed in Step 1. 
    4. Attach the Lens Adapter Ring to the Pitch Adjustment Yoke using the three Lens 
    Rotation Set Screws; see 
    Figure 3-17. Then, attach the lens to the Lens Adapter Ring 
    by threading it clockwise. 
    Figure 3-17. Attaching the Anamorphic Lens to the Lens Ring
    FOCUS
    LENS THREADS
    INTO RINGLens Rotation Set Screws 
    						
    							Installation
    Runco RS-1100 Series Owner’s Operating Manual 35 
    PREL
    IMINARY
    Configure Lens Motor Trigger: CineWide with AutoScope maintains constant image 
    height independent of the aspect ratio, while using the full display resolution of the 
    projector. It accomplishes this by moving the anamorphic lens in front of the primary lens 
    when widescreen material is being viewed. When the viewer transitions back to 16:9 or 
    4:3 source material, the anamorphic lens moves out of the light path.
    To configure the lens motor trigger on the RS-1100 Ultra for proper AutoScope operation: 
    1. Press MENU on the remote control.
    2. Select Service from the Main menu and press ENTER. 
    3. Use the number buttons on the remote to enter the Service menu passcode when 
    prompted and press ENTER again. Then, press MENU on the remote control. 
    4. Select Screen Trigger Mode from the Service menu. 
    5. Set the Screen Trigger Mode to “AutoScope.” This enables the lens motor to move 
    the anamorphic lens into position (in front of the primary lens) when the Cinema or 
    Virtual Cinema aspect ratio is selected. 
    6. Select the Cinema or Virtual Cinema aspect ratio to move the anamorphic lens into 
    position, if it isn’t already. To do this, press CINEMA or VCINE on the RS-1100 
    remote control (
    Figure 2-4). 
    Adjusting the Horizontal (X) Lens Position: 
    1. Project a white field on the screen. 
    2. Loosen the Yaw/X-Adjustment Levers underneath the lens. 
    3. Slowly move the anamorphic lens into place (from right to left or vice versa) so that 
    there are no shadows on either side of the screen: 
     
    4. When the horizontal position is properly set, tighten the Yaw/X-Adjustment Levers to 
    secure the lens in place.
    Adjusting the Height (Y): With the white field still on-screen, loosen the 
    Height/Y
     Adjustment T-Screws on either side of the lens. Then, slowly move the 
    anamorphic lens into place so that there are no shadows on the top or bottom of the 
    screen: 
    Too Far RightToo Far Left
    Correct position 
    						
    							Installation
    36 Runco RS-1100 Series Owner’s Operating Manual
    PREL
    IMINARY
    When the height is properly set, tighten the Height Adjustment T-Screws to secure the 
    lens in place.
    Adjusting the Pitch (Angle): Next, angle the lens to even out any top-to-bottom 
    pincushion distortion. To do this, loosen the Pitch Adjustment T-Screws (directly below 
    the Height/Y Adjustment T-Screws) on either side of the lens to allow it to pivot freely. 
    Then, adjust the anamorphic lens angle so that the projected image is rectangular: 
    The anamorphic lens will almost always be angled with respect to the projector; this is 
    normal.
    Once the proper lens angle has been set, firmly tighten the Pitch Adjustment T-Screws to 
    secure the lens in place. 
    Adjusting the Yaw: Loosen the Yaw/X-Adjustment Levers to allow the lens to pivot freely 
    from side to side. Then, angle the lens to even out any left-right pincushion distortion: 
    There may be some pincushion distortion even after the lens is 
    properly adjusted, especially at shorter throw distances. If this is the 
    case, Runco recommends that you slightly over-scan the image 
    into the screen frame area to mask the distortion. 
    Too HighToo Low
    Correct position
    Correct Lens Angle
    Incorrect Lens Angle
    Note 
    						
    							Installation
    Runco RS-1100 Series Owner’s Operating Manual 37 
    PREL
    IMINARY
    Once the proper lens angle has been set, firmly tighten the Yaw/X-Adjustment Levers to 
    secure the lens in place. 
    Geometry: 
    1. Input an anamorphic cross-hatch test pattern to the projector.
    2. Loosen the three Lens Rotation Set Screws (shown in Figure 3-17) on the lens 
    adapter plate just enough to allow it to rotate freely.
    3. Grasp the lens by the center ring and rotate the lens until the image is properly 
    anamorphic: 
    4. When the image geometry appears correct, tighten the three Lens 
    Rotation Set Screws to secure the lens in place. (When viewed 
    from the front, the rear opening on the anamorphic lens should 
    appear as a tall, narrow oval.) 
    Anamorphic Lens (Top View)
    Wrong PositionCorrect Position
    Wrong Position Correct Position 
    						
    							Installation
    38 Runco RS-1100 Series Owner’s Operating Manual
    PREL
    IMINARY
    Focus: Finally, rotate the Focus Ring on the anamorphic 
    lens to fine-tune the optical focus. 
    Anamorphic Lens 
    Installation and 
    Adjustment - 
    Standard 
    RS-1100/CineWide or 
    RS-1100 Ultra/CineWide
    Standard RS-1100/CineWide (Prismatic Lens): The standard RS-1100 Anamorphic 
    lens mount kit consists of everything shown in 
    Figure 3-18. Some components shipped 
    with your projector may differ slightly from what is shown in these instructions. 
    Figure 3-18. Standard RS-1100 Anamorphic Lens Mounting Assembly - Exploded 
    View
    1. Use the Pitch Adjustment Screws 
    (item #3) and Washers (item #6) to 
    attach the Mounting Brackets (item 
    #2) to the Anamorphic Lens (item 
    #1). 
     
    2. Use the four Y-Adjustment Screws 
    (item #5) and Washers (item #4) to 
    attach the Anamorphic Lens 
    assembly to the front of the 
    projector. (Do not fully tighten the 
    screws yet.)
    Adjusting the Lens Height (Y): 
    1. Project a white field on the screen.
    2. Ensure that the four Height (Y) Adjustment Screws are loose enough to allow vertical 
    movement of the lens assembly. 
    3. Slowly move the anamorphic lens into place so that there are no shadows on the top 
    or bottom of the screen: 
    FOCUS
    ➤
    3   Pitch Adjustment Screw,
         4-40 x 5/16 (4x)
    6   Fender Washer (4x) 2   Mounting Bracket (2x)
    4   Washer (4x)
    5   Y-Adjustment Screw,
         Phillips Pan-Head,
         6-32 x 3/8 (4x) 1    Anamorphic Lens 
    						
    All Runco manuals Comments (0)

    Related Manuals for Runco Rs 1100 Ultra Projector User Manual