Runco Rs 1100 Projector User Manual
Have a look at the manual Runco Rs 1100 Projector User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 123 Runco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Runco RS-1100 Series Owner’s Operating Manual 69 PREL IMINARY 6.1 RS-232 Connection and Port Configuration To interface the RS-1100 with a home theater automation/control system or a PC running terminal emulation software: 1. Connect it to your control system or PC as shown in Figure 3-13. 2. Start a terminal session on your PC using a terminal-emulation program, such as HyperTerminal. 3. Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit and no flow control. Set the baud rate to match that of the projector (115200, 38400 or 9600). 4. Press . You should see a command prompt (>) in the terminal window. 5. Type a command from among those listed in Table 6-1 and press . For example, to change the aspect ratio to Letterbox, type x063x . 6.2 Serial Command Syntax Serial commands to the RS-1100 take the following form: Commands are in ASCII format. Commands are not case-sensitive; X001X and x001x are equivalent. A carriage return MUST follow each command. 6Serial Communications The RS-1100 will not accept serial commands for 20 seconds after it is turned on or off. Table 6-1. Serial Commands CodeFunction x001xPower On x002xPower Off x003xMenu x004xEnter x005xExit x006xUp (arrow key) x007xDown (arrow key) x008xLeft (arrow key) x009xRight (arrow key) x011xShow active source and aspect ratio information x021xKeypad 1 x022xKeypad 2 Note
Serial Communications 70 Runco RS-1100 Series Owner’s Operating Manual PREL IMINARY x023xKeypad 3 x024xKeypad 4 x025xKeypad 5 x026xKeypad 6 x027xKeypad 7 x028xKeypad 8 x029xKeypad 9 x030xKeypad 0 x031xStore image settings to Memory 1 x032xStore image settings to ISF Night x033xStore image settings to ISF Day x046xRestore image settings from Memory 1 x047xRestore image settings from ISF Night x048xRestore image settings from ISF Day x049xLoad default of current source x051xSingle source, full-screen x052xPIP - graphics on video x053xPIP - video on graphics x054xPBP - graphics by video x055xPBP - video by graphics x056xPIP - increase sub-window size x057xPIP - decrease sub-window size x058xSet PIP/PBP active window x061xAnamorphic (16:9) aspect ratio x062xStandard (4:3) aspect ratio x063xLetterbox aspect ratio x064xVirtualWide aspect ratio x065xCinema aspect ratio x066xVirtual Cinema aspect ratio x071xRS-232 baud rate = 9600 x072xRS-232 baud rate = 38400 x073xRS-232 baud rate = 115200 Table 6-1. Serial Commands (continued) Code Function
Serial Communications Runco RS-1100 Series Owner’s Operating Manual 71 PREL IMINARY x081xImage orientation = floor front x082xImage orientation = ceiling front x083xImage orientation = floor rear x084xImage orientation = ceiling rear x091xLamp Power = 200W x092xLamp Power = 250W x121xOSD Language = English x122xOSD Language = French x123xOSD Language = Spanish x124xOSD Language = German x125xOSD Language = Italian x131xSwitch to Composite input x132xSwitch to S-Video input x133xSwitch to RGB-HD input x134xSwitch to HDMI input x135xSwitch to Component 1 input x136xSwitch to Component 2 input x156xBackground Color = Grey x157xBackground Color = Blue x158xBackground Color = White x161xUn-freeze Image x162xFreeze Image x181xToggle Blue Image on/off x261xVertical Lens Shift = Up (incremental) x262xVertical Lens Shift = Down (incremental) x263xZoom Out (incremental) x264xZoom In (incremental) x265xFocus (rotate lens to right) x266xFocus (rotate lens to left) x267xRVR = +1 (larger aperture) x268xRVR = -1 (smaller aperture) x281xVertical Lens Shift = Max. Up Table 6-1. Serial Commands (continued) Code Function
Serial Communications 72 Runco RS-1100 Series Owner’s Operating Manual PREL IMINARY x282xVertical Lens Shift = Max. Down x283xZoom = Max. Out x284xZoom = Max. In x285xFocus (rotate lens to right, full-range) x286xFocus (rotate lens to left, full-range) x287xRVR = Full On (open) x288xRVR = Full Off (closed) Table 6-1. Serial Commands (continued) Code Function
Runco RS-1100 Series Owner’s Operating Manual 73 PREL IMINARY 7.1 RS-1100 Specifications Table 7-1 lists the RS-1100 specifications. 7Specifications Table 7-1. RS-1100 Specifications Projector Type:Digital Light Processing (DLP), Single-Chip SuperOnyx DMD Native Resolution:1920 x 1080 (16:9) Aspect Ratios:4:3, Letterbox, 16:9 Anamorphic, VirtualWide, Cinema, Virtual Cinema Video Standards:NTSC, PAL, SECAM DTV Compatibility:480p, 576p, 720p, 1080i, 1080p Scan Frequency:Horizontal: 15 - 80 kHz Vertical: 50 - 100 Hz Picture Size (16:9 Screen):Recommended Width: 72 in. (1.83 m) to 96 in. (2.44 m) Capable of screen widths between 48 in. (1.22 m) and 200 in. (5.08 m) Throw Distance (Factor x Screen Width):RS-1100: 1.55 to 1.93 (1.86 to 1.93 with CineWide) RS-1100 Ultra: Refer to Table 3-3 Horizontal and Vertical Offset:Refer to Table 3-4
Specifications 74 Runco RS-1100 Series Owner’s Operating Manual PRELI MINARY Brightness and Contrast: Cinema Standards Measurement System (CSMS) Specifications - Brightness*: 14.5 to 21.6 foot-Lamberts (fL) - Contrast Ratio*: 200:1 to 220:1 *Variable depending on RVR setting These measurements are taken from the projector in a controlled, home theater environment. All measurements are made to ANSI/NAPM IT7.228-1997 specifications using the Photo Research PR-650 SpectraColorimeter and Minolta LS-100 Luminance Meter, Video Essentials test DVD and a 1.3 gain, 72-inch wide screen. The projector is calibrated to a color temperature of 6,500K and has a minimum of 150 hours of usage. The foot-Lambert (fL) is the unit of measurement used in commercial movie theaters to express image brightness at the screen surface. The Society of Motion Picture and Television Engineers (SMPTE) specifies 16 fL as the target image brightness for film-based projectors using an open gate (without film in the projector). More importantly, today SMPTE specifies 12 fL as the target image brightness in Digital Cinema theaters. The foot-Lambert measurement is dependent on screen size, screen gain and projector light output. Home Theater Calibration Specifications - Light Output: 442 to 587 ANSI Lumens - Contrast Ratio*: 200:1 to 220:1 These specifications are obtained by calibrating the projector as described above for CSMS measurements. Industry-Standard Specifications - Light Output: 1250 ANSI Lumens - Contrast Ratio: 1500:1 to 3100:1 These are typical projector brightness and contrast specifications found in most companies’ sales literature. Runco includes these measurements in its literature to allow for direct comparison with other manufacturers’ projectors. These measurements are typically taken at 9,000K to 13,000K to get expected performance data when the projector is used in professional, commercial and industrial displays. Lamp:250 Watts Estimated Lamp Life: 2000 hours Video Inputs: (1) Composite Video, (1) S-Video, (1) RGB/Component Video (BNC connectors), (1) RCA Component Video, (1) HDMI Control Options:- Discrete IR remote - Serial commands via RS-232 RS-232 Communication Parameters: 9600, 38400 or 115200 bps, no parity, 8 data bits, 1 stop bit, no flow control +12V Output:Max. 0.25 Amps, active when Cinema or Virtual Cinema Aspect Ratio is selected (CineWide versions only) or when projector is turned on; Tip = +12V; Sleeve = Ground Power Requirements:100 to 240 VAC (auto-sensing), 50/60 Hz, 310 Watts Operating Environment:41°F to 95°F (5°C to 35°C), 20% to 80% humidity (non-condensing) Dimensions:RS-1100: See Figure 7-1 RS-1100 Ultra: See Figure 7-2 Table 7-1. RS-1100 Specifications (continued)
Specifications Runco RS-1100 Series Owner’s Operating Manual 75 PREL IMINARY Weight (without lens):RS-1100: 34 lbs. (15.42 kg) RS-1100 Ultra: 36 lbs. (16.33 kg) Regulatory Approvals:Complies with FCC, CE C-Tick Limited Warranty: Projector: Two (2) years parts and labor from the date of delivery to the end user. Lamp: 1000 hours or six (6) months, whichever comes first. Specifications are subject to change without notice. Table 7-1. RS-1100 Specifications (continued)
Specifications 76 Runco RS-1100 Series Owner’s Operating Manual PRELI MINARY 7.2 RS-1100 Dimensions Figure 7-1 shows the RS-1100 dimensions. Figure 7-1. RS-1100 Dimensions 18.21 in. (462.50 mm)17.72 in. (450.00 mm) 9.84 in. (250.00 mm) 19.69 in. (500.00 mm) 17.32 in. (440.00 mm) 8.86 in. (225.00 mm) 9.25 in (235.00 mm)12.99 in. (330.00 mm) 2.17 in. (55.00 mm) 1.38 in. (35.00 mm) 8.16 in. (207.27 mm) 8.85 in . (224.77 mm)4.43 in. (112.50 mm) 7.28 in. (185.00 mm)
Specifications Runco RS-1100 Series Owner’s Operating Manual 77 PREL IMINARY 7.3 RS-1100 Ultra Dimensions Figure 7-2 shows the RS-1100 Ultra dimensions. Figure 7-2. RS-1100 Ultra Dimensions 0 R 10.6790 0 21.26 in. (540.0 mm) 0.49 in. (12.5 mm) 19.67 in. (499.7 mm)0.20 in. (5.1 mm) 18.11 in. (460.0 mm) 5.12 in. (130.1 mm) 1.17 in. (29.7 mm) 18.50 in. (469.8 mm)13.59 in. (345.1 mm) 6.09 in. (154.6 mm) 9.84 in. (250.00 mm)0.86 in. (21.8 mm) 0.65 in. (16.5 mm) 7.32 in. (185.92 mm)
Specifications 78 Runco RS-1100 Series Owner’s Operating Manual PRELI MINARY Notes: