Ruger P345 Instructions Manual
Here you can view all the pages of manual Ruger P345 Instructions Manual. The Ruger manuals for Firearms are available online for free. You can easily download all the documents as PDF.
Page 21
Any autoloading pistol may occasionally malfunction. If a cartridge hangs up, jams, or binds when being chambered, do not attempt to force it into the chamber by pushing or striking the slide. Carefully remove it. Most failures of a cartridge to feed or to chamber properly are caused by a damaged magazine, incorrect gun handling, insufficient lubrication, or improper ammunition. Whatever the cause, the user of the pistol must, above all, recognize that any cartridge jam can result in the very...
Page 22
to clear the jam. Drawing the slide fully to the rear may bring the jammed cartridge along. Keep your face away from the ejection port during this operation. When attempting to clear a jam, use only wood “tools” so that the cartridge will not be damaged or the primer ignited. A 3/16” wooden dowel with a point on one end is useful. 3. Visually check to make sure that all cartridges have been removed from the pistol. Safely dispose of any cartridges involved in a malfunction incident. Do not use damaged...
Page 23
of a pencil) through top of slide and push ejector downward and forward (see Figure 7, below) until it locks in its lower position. This will permit forward movement of slide. Further disassembly is impossible unless this is done. 23 FIGURE 7 Press slide stop up. Depress ejector.FIGURE 8 Index marks aligned. FIGURE 9 Slide stop in disassembly position. 4. Remove fingers from ejection port. Grasp slide tightly. Now press down on slide stop and allow slide to move slowly forward until the vertical...
Page 24
TO REASSEMBLE 1.Be certain chamber and magazine are empty. 2. With slide held upside down, replace barrel and push it rearward into its locked position. 3. Replace camblock and recoil spring assembly into position. Rear end of camblock seats against barrel lug. Make sure that the large end of the recoil spring goes into the slide. 4. Be certain that ejector is locked in its lower (forward) position and that hammer is in its fired (uncocked) position. 5. Replace slide onto frame far enough to see...
Page 25
DAMAGED, NON-STANDARD, OR IMPROPERLY ASSEMBLED MAGAZINES SHOULD NOT BE USED. THEY CAN CAUSE THE PISTOL TO MALFUNCTION. Snap-On Base- Use a punch to press in on the magazine spring seat where it protrudes into the hole in the magazine floorplate. Slide the magazine floorplate toward the front of the magazine, taking care to prevent the forcible ejection of the magazine spring seat and compressed magazine spring. Withdraw the magazine spring seat and magazine spring from the magazine body. Turn magazine...
Page 26
3. Using powder solvent on a clean patch or bristle brush, remove powder residue from all components of the mechanism. After cleaning, run a dry patch through the bore, then follow with a patch that is very lightly oiled. Wipe all surfaces clean with cloth, then wipe all surfaces with a patch or cloth that has been very lightly oiled. 4.NOTE:Only a light application of oil is needed to provide adequate lubrication of moving parts and to prevent rust. Excess accumulations of oil tend to attract particles...
Page 27
27 OPERATION OF INTERNAL LOCK Never rely upon any safety mechanism or mechanical device to justify unsafe or careless handling of a firearm. When securing your pistol or to prevent unauthorized access, you should rely first and foremost on the key-operated locking device supplied with your pistol. (See Page 6.) However, for added security, and to comply with certain state and local laws, your RUGER ®P345TMpistol is also equipped with a manually operated internal lock. When actuated, this internal lock...
Page 28
28 ALTERNATIVE METHOD II — TO RENDER THE PISTOL INOPERATIVE FOR SAFE STORAGE With the muzzle pointed in a safe direction, remove the magazine, retract the slide, and check the chamber to be sur e the pistol is completely unloaded! Keep the muzzle pointed in a safe direction, and press upward on the slide stop. Insert a finger into the action and press the ejector assembly fully forward. Next, pull the slide stop pin out the left side of the pistol frame until it is withdrawn completely out of the frame....
Page 29
SHIPPING FIREARMS FOR REPAIR: RUGER®P345TMpistols returned to the factory for services or repair should be sent to: Sturm, Ruger & Company, Inc., Product Service Department, 200 Ruger Road, Prescott, AZ 86301-6181. Telephone (928)778-6555. Guns should be sent prepaid. W e will not accept collect shipments. The Federal Gun Control Act, as well as the laws of most States and localities, do not prohibit an individual (who is not otherwise barred from purchasing or possessing a firearm) from shipping a...
Page 30
ORDERING PARTS Please contact the Arizona Product Service Department for parts availability and current prices. All parts orders for the RUGER®P345TMpistols should be sent to: Sturm, Ruger & Company, Inc., Parts Department, 200 Ruger Road, Prescott AZ 86301-6181, (928) 778-6555. We cannot comply with open account or C.O.D. requests. Payment in the form of a check, money order, Visa or Mastercard must accompany your order. Credit Card orders must include the account number, expiration date and whether it...