Page 11

 - 10 - 
 
3.1 PLL CIRCUIT 
The Phase Lock Loop (PLL) circuit is responsible for developing the receiver’s first local oscillator 
signal and the transmitter’s exciter signal. The PLL circuit consists primarily of IC2, IC3, IC4, IC5 
Q25, Q27, Q28, Q29 and Q61. The PLL circuit is programmed by the rotary channel switch GPS-0501. 
The switch communicates the correct binary data information to the programmable divider inside of 
IC3. IC3 then controls the VCO (Voltage Controlled Oscillator), consisting of...

Page 12

 - 11 - 
  

Page 13

 - 12 - 
  

Page 14

 - 13 - 
RCI-6300F HP / RCI-6300F TB FREQUENCY COUNTER CIRCUIT DIAGRAM 
  

Page 15

 - 14 - 
RCI-6300F HP / RCI-6300F TB ECHO BOARD (EB-99) CIRCUIT DIAGRAM 
 
  

Page 16

 - 15 - 
RCI-6300F HP  
RCI-6300F TB  
 CHAPTER 4 
ALIGNMENT 
 
 
 
4.0 REQUIRED TEST EQUIPMENT 
 
! DC Power Supply (13.8VDC, 20A) 
 RF Wattmeter (25~60 MHz, 100W)  
# Multimeter (Digital) 
$ Automatic Modulation Meter 
% Audio Signal Generator 
& Frequency Counter (100 MHz) 
 RF Signal Generator (100 MHz)   
( Automatic Distortion Meter 
) Oscilloscope (50 MHz) 
* Sinad Meter 
 
4.1 ALIGNMENT PROCEDURES 
This transceiver has been aligned at the factory and does not require any adjustments at...

Page 17

 - 16 - 
ITEM U.U.T. SETTING  ADJUST 
POINT MEASUREMENT 
TX Power 
 Set radio to Fr Pool 2, CH 19 AM TX mode. 
Connect “short PCB” to TP7, TP8 and TP9. 
Connect RF Power Meter to antenna jack. 
Set RF Power Fully Clockwise. 
 
 L40,L42,L43,
L44 
 
 
L40,L42 
 
 
 Power MAX. 
Spurious emission 
Min. 
 
Balance Power 
between CH 1 and 
CH 40. 
 
AM TX Power  Set radio to Fr Pool 2, CH 19 AM TX mode. 
Modulation off. 
 VR14 10W (RCI-6300F HP) 
50W (RCI-6300F TB) 
 
RF Power 
Meter Set radio to Fr Pool 2, CH...

Page 18

 - 17 - 
POINT 
AM Sensitivity  Set radio to Fr Pool 2, CH 19 AM RX mode. 
Set RF Gain Fully Clockwise. 
Set SQ Fully Counter Clockwise. 
Set VOL Control at 2 o’clock. 
Set NB-ANL/OFF switch to OFF position. 
Connect RF SG to antenna jack  
Frequency 28.915 MHz, 1uV. Mod 30%. 
Set radio to Pool 6, CH 40 AM mode. 
RF SG setting 29.655 MHz. 
Set radio to Pool 1, CH 1 AM mode. 
RF SG setting 28.245 MHz. 
 L2,3,5,6,7,8, 
9,10 
 
 
 
 
 
L5,L6 
 
L5,L6 
 Audio output > 2V 
S/N > 10 dB. 
 
 
 
 
 
For Balance...

Page 19

 - 18 - 
  
Figure 4-2 Receiver test setup 
 
 
 
 
 
 
 
 
 
 
 
 
  

Page 20

 - 19 - 
  
Figure 4-3 Main PCB Adjustment Location 
 
 
 
 
 
 
 
 
 
 
  