Home > Quasar > Air Conditioner > Quasar Room Air Conditioner Hq2102uh Installation And Operating Instructions

Quasar Room Air Conditioner Hq2102uh Installation And Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Quasar Room Air Conditioner Hq2102uh Installation And Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 140 Quasar manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							INSTALLATION AND
    OPERATING INSTRUCTIONS
    MODEL: HQ-2102UH
    HQ-2122UH
    ROOM AIR CONDITIONER
    F564236
    Please read these operating instructions thoroughly before using
    your air conditioner and keep them for future reference.
    ENGLISH
    For assistance, please call: 1-800-211-PANA (7262) or send e-mail [email protected] or refer to www.panasonic.com
    © 2003 Matsushita Electrical Co., Ltd. All Right Reserved.
    HQ-2102/2122UH (EN)9/12/03, 2:12 PM 1 
    						
    							Please observe these following safety precautions when using
    your air conditioner.
    •Failure or negligence in observing these safety precautions
    could cause fire, electrical shock or personal injury.
    This symbol (with a white background)
    denotes an action that is PROHIBITED.
    1
    SAFETY PRECAUTIONS
    These symbols (with a blue background) denote
    actions that are COMPULSORY.
    INSTALLATION PRECAUTIONS
    OPERATION PRECAUTIONS
    This sign warns of risk of death or serious injury.
    • Do not modify the length of the power cord or use an extension cord.
    • Do not touch or operate with wet hands. Do not modify or damage
    the cord.
    • Do not turn on the unit by inserting the power plug. Do not switch off
    the unit by pulling out the power plug.
    • Avoid an extended period of direct airflow.
    • Do not insert sticks, fingers or other objects into the unit.
    • Do not try to repair the unit yourself.
    • Plug in properly before operating and use a specified power cord.
    • If abnormal conditions (burnt smell, etc) occur, switch off and remove
    the power plug.
    WARNING
    • Do not use the unit for other purposes, than its intended use.
    • Do not remove the power plug by pulling the cord.
    • Do not block the air intake and outlet vanes.
    • Do not splash or direct water at the unit
    • Do not expose the unit to direct sunlight during operation.
    • Do not operate the unit without the air filter installed or when the front
    intake grille has been removed.
    • Do not place any objects on the unit.
    • Do not operate any combustion equipment near the unit’s airflow area.
    • Switch off the breaker and remove the power plug from the socket if
    the unit will not be operated for a long period.
    • Pay attention to any damages on the unit caused by extensive usage.
    • Ventilate the room occasionally where the unit is installed.
    • Remove the power plug when cleaning the unit.
    CAUTION
    2
    AIR CONDITIONER INSTALLATION
    • Due to the weight of this product, we recommend that
    you have a helper to assist in the installation. To avoid
    injury, use the proper method of lifting. Avoid any sharp
    edges.
    • Make sure the window frame to be used can
    properly support this product.
    • This product must be installed in accordance with all local
    codes and ordinances.
    • Do not install the unit in places where inflammable gas,
    fumes or soot may be generated.
    POWER SUPPLY
    • Operate your air conditioner from a stable 115 volt AC
    supply.
    • Plug into a separate 15 amp grounded outlet only.
    • Use of extension cords
    Avoid using extension cords. If there are no alternatives,
    ensure that the cord is a UL listed 3-wire grounding type,
    rated 125 volts with a minimum current-carrying rating of
    15 amps, number 14 or heavier wire.
    • Use a 15 amp time delay fuse or a circuit breaker.
    • Do not switch off by unplugging the power plug while it is
    operating. Press the OFF/ON pad to “OFF” before
    unplugging.
    This sign warns of injury or damage to property.
    OPERATION PRECAUTIONS
    Time Delay Fuse : 15 Amps
    Rated Voltage : 115V
    • Socket Type• Line Cord Plug
    INSTALLATION BOX CONTENTS
    Sealer 50 g
    (1.8 oz) (Putty)
    Type A
    screw Window sash
    sealing ribbon
    Type C screws
    Type B screws Left side
    expandable panel Type A
    screws
    Type C screwsTo p
    angleWindow sash
    foam seal
    Right side
    expandable
    panelType A Type  B Type  C
    (Qty 6) (Qty 5) (Qty 6)
    SCREW FURNISHED
    Wood Machine Tapping
    Screw Screw Screw
    SUGGESTED TOOL LIST
    Medium sized
    screwdriver (#2
    Phillips)
    Tape Measure
    Pencil
    Level
    Knife or
    Scissor
    ACCESSORIES
    NOTE
    Check that none of the accessories are missing.
    (6 pcs)
    (XTN5D25A)
    (5 pcs)
    (CWH4580211)
    (6 pcs)
    (XTT4D8C)
    SELECT THE BEST LOCATION
    (Single or Double
    hung window)19–3/16 inches
    SIDE VIEW
    Front grilleWindow
    12 inches
    More than
    4 inches Type A  screws Type A  screwTop sealing
    ribbonSide
    sealing
    ribbon
    HQ-2102/2122UH (EN)9/12/03, 2:12 PM 2 
    						
    							WINDOW REQUIREMENTS
    • Hot sun rays hitting the outside surface
    of the cabinet will create considerable
    heat load. If the outside of the cabinet is
    exposed to direct sunlight, consider
    building an awning to shade the cabinet
    while providing ample area for the heated
    air to be exhausted from the condenser
    (both sides) and the top.
    This unit is designed for installation in
    standard double hung windows.
    NOTE
    The unit may also be installed “through the wall”. You should,
    however, observe standard carpentry practices and frame the
    opening without violating local ordinances.
    INSTALLATION PROCEDURES
    HOW TO ASSEMBLE THE EXPANDABLE PANELS
    Top angle
    Type B screws
    Type C screws
    • Attach the top angle to the cabinet using screw type B (3 pcs).
    • Insert expandable panels to cabinet sides as shown.
    • Secure the first fold of expansion panel to cabinet using screw
    type C (3 each).
    Expandable panel
    CHASSIS INSTALLATION INTO THE CABINET
    1Remove the rear cabinet
    screws and save for later use.
    2Slide the chassis out from the
    cabinet.
    CABINET INSTALLATION
    1Cut the “Sealing Ribbon” to the
    proper length, and attach it along
    the bottom edge of the bottom
    window sash.
    2To prevent condensation water
    from dripping inside, the cabinet
    should be installed level or very
    slightly tilted to the outside.
    3Secure the cabinet using screws.
    • Expand the expandable panel fully into the grooves of the
    window frame, secure the expandable panel, left, right and
    top mounting frames to the bottom of the window sash
    using 6 screws type A and 2 screws type B.
    • Secure the cabinet using wood screws type A.
    • Cut the window sash foam seal to the proper size and
    seal the opening between the top of the inside window
    sash and the outside window sash.
    Note : If a gap exists between the unit and window sash, you may
    use “Sealer” supplied with the installation kit for a better seal.
    Window sash
    sealing ribbon
    1Slide the chassis into the cabinet.
    2Reinstall the cabinet screws.
    Secure the cabinet to chassis by using screws (from
    rear cabinet).
    INSTALLATION OF THE FRONT GRILLE
    Depending upon the location
    of the AC outlet, route the AC
    cord to either the left or right
    side while installing the front
    grille.
    This figure shows the AC cord
    routed to the left side.
    INSERT THE  (OPTIONAL)
    Attach the  (part no.
    CZ-SF6P)  to the frame.Slot in the  and the
    frame (part no. CZ-SFW6P) to
    the front grille.
    The  and the frame can be obtained separately
    from your nearest service center.
    INSERT THE AIR FILTER
    Attach the air filter to the intake grille
    PLACE FRONT INTAKE GRILLE OVER THE FRONT GRILLE
    Slide the front intake grille slightly to the right to reattach the
    tabs and then push it down to close tight.
    NOTE
    This procedure applies to left and right
    of assembling expandable panel.
    O
    F
    F
    /O
    NO
    P
    E
    R
    ATIO
    NTEMP/TIMERCOOL
    FAN
    HIGH
    MED
    LOWMODE
    FAN SPEEDSETTIM
    ERSET/
    CANCELAIR SWINGECONOMYhr °FWirelessRemote Control
    O
    F
    F
    /
    O
    NOPERATIONT
    E
    M
    P
    /
    T
    IM
    E
    RCOOL
    FA N
    HIGH
    MED
    LOWMODE
    FAN SPEEDS
    E
    TT
    I
    M
    E
    RS
    E
    T
    /
    C
    A
    N
    C
    E
    LAIR SWINGE
    C
    O
    N
    O
    M
    Yh
    r °
    FWirelessR
    e
    m
    o
    t
    e
     
    C
    o
    n
    tr
    o
    l
    O
    F
    F
    /O
    NO
    P
    E
    R
    A
    T
    I
    O
    NTEMP/TIMERCOOL
    FAN
    HIGH
    MED
    LOWMODE
    FAN SPEEDSETT
    IM
    E
    RSET/
    CANCELAIR SWINGECONOMYhr °FWirelessRemote Control
    O
    F
    F
    /
    O
    NOPERATIONT
    E
    M
    P
    /
    T
    I
    M
    E
    RC
    O
    O
    L
    F
    A
    N
    H
    I
    G
    H
    M
    E
    D
    L
    O
    WM
    O
    D
    E
    F
    A
    N
     
    S
    P
    E
    E
    DS
    E
    TTIMERS
    E
    T
    /
    C
    A
    N
    C
    E
    LA
    I
    R
     
    S
    W
    I
    N
    GE
    C
    O
    N
    O
    M
    Yh
    r °
    FW
    i
    r
    e
    l
    e
    s
    sRemote Control
    O
    F
    F
    /
    O
    NOPERAT IONT
    E
    M
    P
    /
    T
    I
    M
    E
    RC
    O
    O
    L
    F
    A
    N
    H
    I
    G
    H
    M
    E
    D
    L
    O
    WM
    O
    D
    E
    F
    A
    N
     
    S
    P
    E
    E
    DS
    E
    TTIMERSET/
    CANCELA
    I
    R
     
    S
    W
    I
    N
    GE
    C
    O
    N
    O
    M
    Yh
    r °
    FWirelessRemote Control
    OFF/ONOPERATIONTEMP/TIMERCOOL
    FAN
    HIGH
    MED
    LOWMODE
    FAN SPEEDSETT
    I
    M
    E
    RSET
    /
    CANCELAIR SWINGECONOMYh
    r °
    FW
    i
    r
    e
    l
    e
    s
    sRemo
    te C
    ontr
    ol
    1Place the front grille on the
    cabinet first.
    2Secure the front grille to the
    main chassis using screw
    provided.
    15-15/16” (min)22  to 42-1/8”
    Top sealing
    ribbon (To be
    attached to the
    top angle)
    Side sealing ribbon
    (To be attached to
    the expandable
    panel)
    Window sash
    foam seal Type A
    screw
    Type B
    screws
    Window sill
    Type A
    screwsExpandable panel
    Outside of sash
    Window sash
    Sealing ribbon Top angleInside of
    sash
    O
    F
    F
    /
    O
    NO
    P
    E
    R
    A
    T
    I
    O
    NTEMP/TIMERCOO
    L
    F
    A
    N
    HI
    GH
    MED
    L
    O
    WMO
    D
    E
    F
    A
    N 
    SP
    EE
    DSETT
    I
    M
    E
    RSET/
    CANCELAI
    R
     SW
    IN
    GECONOMYhr °FWirelessR
    e
    m
    o
    t
    e
     
    C
    o
    n
    t
    r
    o
    l
    Clockwise.
    HQ-2102/2122UH (EN)9/12/03, 2:12 PM 3 
    						
    							1Air inlet louver4Air filter (behind the
    front intake grille)
    2Cabinet5Front intake
    grille
    3Power cord6Front grille
    7Vertical airflow direction vane
    (Airflow direction adjustment up-
    down).
    The vertical airflow direction vane
    is controlled by rotating the
    horizontal vane forward or backward.
    2
    AIR CONDITIONER INSTALLATION
    3
    PART IDENTIFICATION
    REMOVAL OF FRONT GRILLE
    1Remove the front intake grille.
    Pull up the front intake
    grille about 90° and slide
    it slightly to the left to
    unhook the tabs.2Remove the air filter.
    Tilt up and pull
    out the air filter
    by the holder.
    3Remove the front grille.
    a aa a
    aAt bottom right side of the front grille, press inward on cabinet near the power cord, and pull
    the grille outward to the right until right tab releases.
    b bb b
    bAt the bottom left side, push inward on cabinet and pull the grille outward to the left to release
    the left tab.
    Do not pull the bottom edge toward you more than 3 inches to prevent the two top tabs from
    damage.
    c cc c
    cSlide the front grille upwards to free the two top tabs from slots at the top of the cabinet.
    HOW TO ATTACH THE DRAIN PAN (OPTIONAL)
    Maximum
    13/32”
    Condensed water
    This air conditioner employs a “Slinger-Up System” which is designed to splash the condensed
    water on the condenser coil for maximum cooling efficiency, thus producing a splashing sound.
    If the splashing sound annoys you, you can provide an outside drainage by using the following
    procedure which may, however, cause a small loss of performance.
    Note: The cabinet should be installed tilted slightly lower to the rear for necessary condensate
    drainage. (Max. 13/32”)
    Condensed water drainage
    1Remove the rubber plug and slide the chassis out from
    the cabinet.
    Remove the
    rubber plug
    OFF/ONOPERATIONT
    E
    M
    P
    /
    T
    I
    M
    E
    RC
    O
    O
    L
    F
    A
    N
    H
    I
    G
    H
    M
    E
    D
    L
    O
    WM
    O
    D
    E
    F
    A
    N
     
    S
    P
    E
    E
    DS
    E
    TTIMERS
    E
    T
    /
    C
    A
    N
    C
    E
    LA
    I
    R
     
    S
    W
    I
    N
    GE
    C
    O
    N
    O
    M
    Yhr °FW
    ire
    le
    s
    sR
    e
    m
    o
    t
    e
     
    C
    o
    n
    t
    r
    o
    l
    2Install the optional drain pan (part no. CWH40175).
    ScrewsINTERNAL VIEW
    Drain pan (optional)
    Install the drain pan at the right
    corner of the cabinet using 2
    screws (part no. CWG86C733).
    3Connect a drain hose (optional).
    Fit the drain hose to the drain pan.
    Under-side view with drain
    pan and hose in place.
    Drain hose
    (not included)
    4Slide the chassis back into the
    cabinet.
    Reinstall the cabinet screws.
    Secure the cabinet to chassis by
    using screws.
    Note
    The drain pan (part no.
    CWH40175) can be obtained
    from nearest service center.
    MAIN UNIT
    O
    F
    F
    /
    O
    NO
    P
    E
    R
    A
    T
    I
    O
    NT
    E
    M
    P
    /
    T
    I
    M
    E
    RC
    O
    O
    L
    F
    A
    N
    H
    IG
    H
    M
    E
    D
    L
    O
    WM
    OD
    E
    F
    A
    N
     S
    P
    E
    E
    DS
    E
    TTIMERSET/
    CANCELA
    IR
     S
    W
    IN
    GECONOMYh
    r °
    FWirelessRemote Control
    9Touch control panel
    OFF/ONOPERATIONTEMP/TIMER
    COOL
    FA N
    HIGH
    MED
    LOWMODE
    FAN SPEED
    SETTIMERSET/
    CANCEL
    AIR SWINGECONOMY
    hr °F
    WirelessRemote Control
    aDisplay Panel
    bMODE selection pad
    cFAN SPEED selection pad
    dTEMPERATURE/TIMER
    setting pad
    eTIMER pad
     fTimer SET/CANCEL pad
    gOPERATION OFF/ON pad
    hAIR SWING pad
     iECONOMY pad
    a
    b
    c
    de
    fg
    hi
    Note
    Drain hose or tubing can be
    purchased locally to satisfy your
    particular needs.
    TYPES OF SIGNAL SOUND
    One long “Beep” and one short “Beep”. (Sound from the main unit.)EXTERNAL VIEW
    12
    3
    4
    5
    6
    8
    7
    9
    O
    F
    F
    /
    O
    NOPERATIONTEMP/TIMERC
    O
    O
    L
    F
    A
    N
    H
    I
    G
    H
    M
    E
    D
    L
    O
    WM
    O
    D
    E
    F
    A
    N
     
    S
    P
    E
    E
    DSETTIMERS
    E
    T
    /
    C
    A
    N
    C
    E
    LA
    I
    R
     
    S
    W
    I
    N
    GECONOMYhr °FWirelessRemote Control
    Air filter
    O
    F
    F/
    O
    NOPERATIONTEMP/TIMERC
    O
    O
    L
    F
    A
    N
    H
    I
    G
    H
    M
    E
    D
    L
    O
    WM
    O
    D
    E
    F
    A
    N
     
    S
    P
    E
    E
    DSETTIMERS
    E
    T
    /
    C
    A
    N
    C
    E
    LA
    I
    R
     
    S
    W
    I
    N
    GECONOMYhr °FW
    i
    r
    e
    l
    e
    s
    sRemote Control
    a aa a
    a b bb b
    b
    c cc c
    c
    O
    F
    F
    /
    O
    NOPER
    ATI
    ONTEMP/
    TIMERC
    O
    O
    L
    F
    A
    N
    H
    I
    G
    H
    M
    E
    D
    L
    O
    WM
    O
    D
    E
    F
    A
    N
     
    S
    P
    E
    E
    DSETTIMERS
    E
    T
    /
    C
    A
    N
    C
    E
    LA
    I
    R
     
    S
    W
    I
    N
    GECONOMYhr °FWirelessRemote Control
    OFF/ONOP
    E
    R
    AT
    IO
    NTEMP/TIMERC
    OOL
    F
    AN
    HIGH
    ME
    D
    LOWM
    ODE
    FA N  S P E
    EDSETTIMERS
    E
    T
    /
    C
    A
    N
    C
    E
    LAIR SWINGECONOMYhr °FWirelessRemote Control
    8Ventilation lever
    The ventilation lever must be in the CLOSE position in order to
    maintain the best cooling conditions. When fresh air is necessary
    in the room, set the ventilation lever to the OPEN position. The
    damper is opened and room air is drawn out.
    OFF/ONO
    P
    E
    R
    A
    T
    I
    O
    NTEMP/TIMERCOOL
    FA N
    HIGH
    MED
    LOWMODE
    FAN SPEEDSETTIMERS
    E
    T
    /
    C
    A
    N
    C
    E
    LAIR SWINGECONOMYh
    r °F
    WirelessRemote Control
    HQ-2102/2122UH (EN)9/12/03, 2:12 PM 4 
    						
    							3
    PART
    IDENTIFICATION
    4
    PREPARATION BEFORE
    OPERATING
    ACCESSORIES
    •Remote control•Two R03 dry-cell batteriesBe sure to observe the following:
    •Aim remote control at control
    panel on air conditioner when
    operating.
    •Do not drop or throw the remote
    control.
    •Do not place the remote control
    in a location that is exposed to
    direct sunlight or next to a heating
    unit or other heat sources.
    O
    F
    F
    /
    O
    NOPERATIONT
    E
    M
    P
    /
    T
    I
    M
    E
    RCOOL
    FAN
    HIGH
    LOWM
    ODE
    FAN 
    SPEEDS
    E
    TT
    I
    M
    E
    RS
    E
    T
    /
    C
    A
    N
    C
    E
    LAI
    R SWINGP
    O
    W
    E
    R
    FU
    Lh
    r °
    CW
    ir
    e
    l
    e
    s
    sR
    em
    o
    t
    e
     C
    o
    n
    t
    ro
    l
    • Maximum distance : 10 m  (32.8 ft.)
    AIR SWINGMODEOPERATIONFAN SPEEDECONOMY
    SET/
    CANCEL TEMP/TIMER
    TIMER
    1Signal Transmitter
    2OPERATION button
    3TEMPERATURE/TIMER setting button
    4TIMER button
    5TIMER SET/CANCEL button
    6MODE selection button
    7ECONOMY Button
    8AIR SWING button
    9Fan Speed Selection Button
    REMOTE CONTROL1
    2
    3
    5
    7
    9
    6
    8
    4
    NOTES
    •If the unit is not going to be used for an extended period of time, remove the
    power plug. Otherwise, approximately 2.5W of electricity will be used even if the
    unit has been turned off using the remote control.
    •If operation is stopped, and to be restarted immediately, the unit will resume
    operation only after 3 minutes.
    ABOUT THE BATTERIES
    WARNING
    31
    Open the cover.
    HOW TO INSERT BATTERIES
    Insert the two batteries.
    2
    Do not use rechargeable (Ni-Cd) batteries
    because such batteries differ from the standard
    dry cell batteries in shape, dimension and
    performance.
    Close the cover.
    CAUTION
    Ensure that the power
    plug is securely inserted.
    A loose plug may cause a
    fire or an electric shock.
    •The batteries can be used for approximately one year.
    •Be sure to replace the batteries with two new identical
    batteries.
    •Remove the batteries if the air conditioner will not be used
    for an extended period of time.
    5
    AIR CONDITIONER OPERATION
    OPERATING THE UNIT
    Start operation by pressing
    OPERATION.
    The operation will turn on and the
    display panel will light up.
    To stop the operation, press the
    OPERATION again.
    The unit will stop operating and the
    display panel light will turn off.
    SELECTING OPERATION MODE
    Press MODE to select the desired
    operation .
    The indicator will light up and a “beep”
    sound will indicate changing setting.
    COOL mode
    To set room temperature to your
    preference of cooling comfort.
    FAN mode
    To provide air circulation without cooling
    the room.
    During Fan operation, temperature
    setting cannot be selected.
    SETTING DISPLAY TEMPERATURE
    Press TEMP/TIMER  or  to set the
    display temperature.
    The temperature can be set between
    60°F and 86°F.
    Recommended temperature:
    75°F ~ 78°F.
    Display will
    change
    according to
    the setting.
    NOTES
    •The latest temperature setting will be memorized and will
    appear on the display the next time it’s turned on.
    •The display temperature selection is for display purpose only
    and does not indicate actual room setting temperatures. Your
    room temperature may not necessarily match the displayed
    temperature.
    SELECTING FAN SPEED
    Press FAN SPEED to choose the
    speed level of the fan.
    The indicator will light up and the “beep”
    sound will indicate changing setting.
    Vertical
    louvers
    ADJUSTING HORIZONTAL AIR FLOW DIRECTION
    Press to select AIR SWING.
    The air circulation will automatically move the
    horizontal louvers left and right for better air
    distribution around the room.
    NOTE
    Using your hands to adjust the direction may cause
    the louvers to malfunction. If this happens, stop
    operation immediately and restart.
    NOTE
    Vertical adjustment of the airflow direction
    is done manually.
    NOTE
    •The latest fan speed setting will be memorized and the indicator
    will light up the next time the unit is turned on.
    OFF/ON
    OPERATION
    OPERATION
    TEMP/TIMER
    COOL
    FA NMODE
    TEMP/TIMER
    hr°F
    hr°F
    hr°F
    FAN SPEED
    AIR SWING
    MODE
    HIGH
    MED
    LOWFAN SPEEDAIR SWING
    COOL
    FA N
    HIGH
    MED
    LOW
    O
    FF
    /O
    NO
    P
    E
    R
    A
    T
    IO
    NT
    E
    M
    P
    /T
    I
    M
    E
    RCOOL
    FA N
    HIGH
    MED
    LOWMODE
    FAN SPEEDS
    E
    TT
    I
    M
    E
    RSET/
    CANCELAIR SWINGECONOMYhr °FW
    ire
    le
    s
    sRemote Control
    HQ-2102/2122UH (EN)9/12/03, 2:13 PM 5 
    						
    							5
    AIR CONDITIONER OPERATION
    6
    PRODUCT SPECIFICATIONS
    ModelHQ-2102UH HQ-2122UH
    COOLING CAPACITY Btu/h 10,000 11,500
    ELECTRICAL RATING Phase Single+
    Frequency (Hz) 60+
    Voltage (V) 115+
    Current (Amps) 8.7 9.8
    Input (W) 980 1120
    EER (Btu/W.h) 10.2+
    MOISTURE REMOVAL (Pints/h) 2.5 3.0
    ROOM AIR CIRCULATION (Cf/min) 320 330
    DIMENSIONS Height cm (inches) 37.5 (14-25/32˝)+
    Width cm (inches) 56 (22-1/16˝)+Depth cm (inches) 60.6 (23-27/32˝)+
    NET WEIGHT kg (lb) 35 (77)+
    GROSS WEIGHT kg (lb) 39 (86)+
    NOISE LEVEL Indoor (Hi/Lo) dB (A) 50/46 51/47
    Outdoor (Hi/Lo) dB (A) 57/54 58/55
    ECONOMY OPERATION
    To reduce power consumption:
    •Press ECONOMY.
    •To cancel this operation, press once
    more.
    ECONOMY
    Recommended for electricity cost saving. When economy button is
    pressed, target temperature is shifted up 1°F, this will reduce operating
    time of the compressor and therefore reduce power consumption. It
    may, however, take a little longer for the compressor to cycle on and
    thereby increase the room temperature slightly. Economy mode will
    override your current set fan speed to “LOW”. However, the display will
    still show the current set fan speed. Compressor stops when the room
    temperature reaches the target temperature.  It turns on again when
    the room temperature rises. When power failure occurs, the economy
    setting is canceled. Once power is resumed, reset the economy setting.
    SETTING THE OFF TIMER
    When the air conditioner in operation:
    Press the TIMER button.
    The SET/CANCEL indicator light will
    blink awaiting for setting.
    Press the TEMP/TIMER 
     or  button
    until the preferred hour of operation is
    reached.
    Press the SET/CANCEL button to
    complete the setting. At this time, the
    SET/CANCEL indicator light is steady
    instead of blinking.
    NOTE
    The hour reading will change back to  the
    set temperature reading after 10
    seconds. (You can also revert to
    temperature setting immediately by
    pressing the TEMP/TIMER 
     or buttons again.)
    CHECK TIMER SETTING DURING OFF TIMER
    Press the TIMER button to check the
    remaining programmed timer setting.
    The figure will be displayed for 10
    seconds then will automatically switch
    back to temperature setting.
    NOTE
    The timer figure will change according
    to the time remaining (if you set it to turn
    off 3 hours from now, the timer will show
    “2” at an hour later).
    CANCEL TIMER SETTING DURING OFF TIMER
    Press the SET/CANCEL button to cancel
    the timer setting. The SET/CANCEL
    indicator light will turn off. However the
    temperature remains displayed.
    SETTING THE ON TIMER
    When the air conditioner in operation:
    Press the TIMER button. The TIMER
    indicator light will blink to await for setting.
    Press the TEMP/TIMER
      or  button
    until the desired hour for operation is
    reached. Press the SET/CANCEL button
    to complete the setting. At this time, the
    TIMER indicator light is steady instead of
    blinking.
    The display will show the remaining hour
    to the start of the operation (if you set to
    turn on 3 hours from now, the timer will
    show “2” at an hour later).
    When set time is reached, the air
    conditioner starts the operation under the
    previous setting mode and the TIMER
    indicator will light off. Now, the previous
    set mode and the fan speed will light up.
    Simultaneously, the display will show the
    setting temperature.
    CHECK TEMPERATURE/MODE/FAN SPEED
    SETTING DURING ON TIMER
    Press the TIMER button. The TIMER
    indicator light will blink and the previous
    temperature setting will be shown.
    Simultaneously, MODE and FAN
    SPEED indicator will light up. This
    indication will last for 5 seconds, and
    then the display will show the remaining
    time. MODE and FAN SPEED indicator
    light will turn off. At this time, the TIMER
    indicator light is steady instead of
    blinking.
    CHANGE TEMPERATURE/MODE/FAN SPEED
    SETTING DURING ON TIMER
    Press the SET/CANCEL button to
    cancel the timer setting.
    Press the OPERATION. Set the desired
    mode and the fan speed. Then press
    OPERATION button to stop operation.
    Start the TIMER setting again by
    repeating the step from the “Setting the
    on timer” procedures).
    CANCEL TIMER SETTING DURING ON TIMER
    Press the SET/CANCEL button to cancel the
    timer setting. The SET/CANCEL indicator
    light will turn off. To operate the air
    conditioner before reaching the set timer:
    •Press the SET/CANCEL to cancel the
    timer.
    •Press the OPERATION button to turn on
    the unit.
    ECONOMY
    TIMER
    TEMP/TIMER
    SETSET/
    CANCEL
    TIMER
    SETSET/
    CANCEL
    TIMER
    TEMP/TIMER
    SETSET/
    CANCEL
    TIMER
    TIMER
    SETSET/
    CANCEL
    OFF/ONOPERATION
    SETSET/
    CANCEL
    OFF/ON
    OPERATION
    ECONOMY
    TIMER
    TEMP/TIMER
    SET/
    CANCEL
    TIMER
    SET/
    CANCEL
    SET/
    CANCEL
    OPERATION
    SET/
    CANCEL
    OPERATION
    TIMER
    TIMER
    TIMER
    TEMP/TIMER
    SET/
    CANCEL
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    hr°F
    *  Specifications are subject to change without notice for further improvement.
    HQ-2102/2122UH (EN)9/12/03, 2:13 PM 6 
    						
    							7
    HELPFUL INFORMATION &
    ENERGY SAVING HINTS
    HELPFUL INFORMATION
    Random Auto  Restart
    •Operation will automatically
    resume under the previous
    operation mode.
    •If the unit was set to TIMER
    mode, operation will not resume
    automatically.
    Timer Setting
    •When power failure occurs, the
    timer setting is canceled. Once
    power returns, reset the timer.
    ENERGY SAVING HINTS
    •Setting the temperature 1°F higher save
    10% electricity costs.
    •Clean the air filter every 2 weeks. Regular
    cleaning of the air filter preserves efficiency.
    •Keeping openings closed keeps cool air in
    and hot air out.
    •Avoid direct sunlight and heat.
    •For health reasons do not overcool your
    room.
    •Your air conditioner’s cooling capacity
    should match your room size.
    Always turn off the air conditioner and the main power supply before clean the unit.
    Switch off the power supply if the unit is not going to be used for a long period of time.CAUTION
    •Clean the cabinet, front grille with a mild soap or detergent and lukewarm water.
    •The front intake grille can be easily removed for cleaning purposes (refer to Remove the front intake grille procedures). Gently
    wash it with water and a sponge.
    •The filter can be easily cleaned using a vacuum cleaner.  Vacuum the front of the filter and then wash the rear with water. If it is
    badly soiled, wash with a mild household detergent.
    It is recommended to replace the 
     (part no.CZ-SF6P) every 3 months.
    •Do not clean with benzene, thinner, scouring powder or cloth soaked in caustic chemicals.
    •If the unit is extremely dirty, heat transfer is less efficient and the unit may not cool effectively. Contact your nearest servicenter
    for an annual check. (Annual check is not covered under warranty)
    •If the air filter becomes clogged with dust, the cooling capacity will drop, and 6% of the electricity used to operate the air
    conditioner will be wasted.
    NOTE
    Do not dry the front panel or the air filter in direct sunlight. (Exposure to direct sunlight may discolor or deform the panel.)
    PRE-SEASON INSPECTION
    •Is the discharged air cold?
    After 15 minutes of operation, it is normal for the temperature
    difference between intake and outlet air to be more than 14.4°F
    for cooling.
    •
    Are the air intake and outlet vanes of the indoor and outdoor
    side obstructed?
    •Are the remote control batteries weak?
    RECOMMENDED INSPECTION
    •Usage over several seasons will reduce performance as the
    unit becomes dirty.
    A dirty unit may produce foul odors and dust may clog the
    dehumidifying drainage.
    Seasonal inspection is recommended in addition to regular
    cleaning. Consult your nearest service center.
    8
    CARE AND MAINTENANCE
    9
    BEFORE CALLING FOR SERVICE
    Check the following points before calling for repairs or service. If the malfunction persists, please contact your
    nearest service center. For assistance, please call: 1-800-211-PANA (7262) or send e-mail to:
    [email protected]
    POSSIBLE CAUSES OF THE ABOVE PROBLEMS
    Condition  1If the unit is too noisy during operation.
    The following sounds are normal during operation:
    •A low humming sound indicating that the unit is operating.
    •A soft clicking sound when the compressor turns on and off.
    •A flowing sound due to circulation of the refrigerant when the
    compressor is turned on.
    •A splashing sound indicating condensation in the condenser
    coil.
    If you hear other noises, please consult your nearest servicenter.
    Condition  2If the unit does not operate.
    •The main power cord is not plugged in.
    •The internal fuse has blown.
    •The main circuit breaker has tripped.
    •Remote control batteries are weak.
    Condition  3If the unit does not cool properly.
    •The room is too big for the unit’s cooling capacity.
    •The ventilation lever is set to OPEN.
    •The air circulation is impeded by curtains or furniture.
    •After 15 minutes of operation, it is normal for the temperature
    difference between intake and outlet air to be more than 14.4°F
    for cooling.
    Condition  4If water drips off the rear of the unit.
    •Humidity is high.
    •Condensed water is overflowing.
    •To rectify the problem, mount an optional drain pan to the
    unit.
    Condition  5If water drips inside the room.
    •The unit is tilted inward. To rectify this, tilt the unit slightly
    outward.
    •Mount the optional drain pan if you prefer.
    •The drain pan may be blocked.
    If the trouble persists after you have checked all of these,
    call your authorized Panasonic dealer or servicenter.
    Service information can be obtained 24 hours/day by calling:
    1-800-211-PANA (7262)
    To expedite the repair of your air conditioner:
    • Please have your proof of purchase.
    • List all symptoms the unit is exhibiting.
    HQ-2102/2122UH (EN)9/12/03, 2:13 PM 7     
    						
    							Panasonic Consumer Electronics Company,
    Division of Matsushita Electric Corporation
    of America
    One Panasonic Way
    Secaucus, New Jersey 07094
    Quasar Room Air Conditioner
    Limited Warranty
    Panasonic Consumer Electronics Company or Panasonic Sales Company (collectively referred to as “the Warrantor”) will repair this
    product with new or refurbished parts in case of defects in material or workmanship, free of charge, in the USA or Puerto Rico in accordance
    to the following (All time periods start from the date of the original purchase).
    SEALED REFRIGERATING SYSTEM (compressor and interconnecting tube): FIVE (5) YEARS - PARTS AND LABOR
    ALL OTHER COMPONENTS: ONE (1) YEAR - PARTS AND LABOR
    In-home service in the USA can be obtained during the warranty period by contacting a Panasonic Service Company (PASC) Factory
    Servicenter listed in the Servicenter Directory. Or call toll free, 1-800-211-PANA(7262), to locate a PASC authorized Servicenter. In-home
    service in Puerto Rico can be obtained during the warranty period by calling the Panasonic Sales Company telephone number listed in the
    Servicenter Directory.
    Note: If the unit is installed at the other than normal window height and/or has been
    custom-installed (e.g., through the wall), the customer is responsible for removing
    the unit from its installation prior to the performance of in-home service.
    This warranty is extended only to the original purchaser. A purchase receipt or other proof of date of the original purchase is required for
    service and parts replacement under this warranty.
    This warranty only covers failures due to defects in materials and workmanship and does not cover normal wear or cosmetic damage. The
    warranty does not cover damages which occur in shipment, or failures which are caused by products not supplied by the warrantor, or
    failures which result from accident, misuse, abuse, neglect, mishandling, misapplication, faulty installation, maladjustment of customer
    controls, improper maintenance, alteration, modification, power line surge, lightning damage, improper voltage supply, commercial use
    such as hotel, office, restaurant, or other business or rental use of the product, or service by anyone other than a PASC Factory Servicenter
    or a PASC authorized Servicenter, or damage that is attributable to acts of God.
    LIMITS AND EXCLUSIONS
    There are no express warranties except as listed above.
    THE WARRANTOR SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE
    USE OF THIS PRODUCT, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY. ALL EXPRESS AND IMPLIED
    WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY, ARE LIMITED TO THE APPLICABLE WARRANTY
    PERIOD SET FORTH ABOVE.
    Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations on how long an implied
    warranty lasts, so the above exclusions or limitations may not apply to you.
    This warranty gives you specific legal rights and you may also have other rights which vary from state to state. If a problem with this
    product develops during or after the warranty period, you may contact your dealer or Servicenter. If the problem is not handled to your
    satisfaction, then write to the Consumer Affairs Department at the company address indicated above.
    SERVICE CALLS WHICH DO NOT INVOLVE DEFECTIVE MATERIALS OR WORKMANSHIP AS DETERMINED
    BY THE WARRANTOR, IN ITS SOLE DISCRETION, ARE NOT COVERED. COSTS OF SUCH SERVICE CALLS ARE
    THE RESPONSIBILITY OF THE PURCHASER.
    [For assistance, please call: 1-800-211-PANA (7262) or send e-mail to [email protected]]
    F564236
    Printed in Malaysia
    F0310-0
    Panasonic Sales Company,
    Division of Matsushita Electric of Puerto Rico, Inc.,
    Ave. 65 de Infanteria, Km. 9.5
    San Gabriel Industrial Park
    Carolina, Puerto Rico 00985
    HQ-2102/2122UH (EN)9/12/03, 2:13 PM 8 
    						
    All Quasar manuals Comments (0)

    Related Manuals for Quasar Room Air Conditioner Hq2102uh Installation And Operating Instructions