    							Operation
    Planar PD8130/PD8150 Installation/Operation Manual 57 
    PRELI
    MINAR
    Y
    Logo Display: This controls whether or not the Planar logo appears during 
    startup.
    Power On Chime: This controls the audible chime at startup.
    ControlSelect Control from the Main Menu to set various options related to control of 
    the projector. 
    1 Key / 2 Key / 3 Key / 4 Key / 5 Key: These menu items assign the function of 
    the keys numbered 1 through 5 on the remote.
    There are eight sources corresponding to the eight connections to the 
    projector. When you assign a source to a numbered key, the projector 
    immediately goes to that source when the key assigned to it is pressed. 
    If the chosen source is disabled via the Source Enable menu (refer to page 54), 
    this setting has no effect.
    M1 Key / M2 Key / M3 Key: These menu items assign which memory setting to 
    recall when the M1, M2 or M3 key on the remote is pressed.
    Trigger 1: Select Trigger 1 from the Control menu to specify when the Trigger 1 
    port outputs 12 volts. There is a three-second delay before activation to prevent 
    operation while selecting an aspect ratio.
    •Lamp causes the port to output 12 volts whenever the lamp is on.
    •16:9 causes the port to output 12 volts whenever the 16:9 aspect ratio is 
    chosen.
    •Letterbox causes the port to output 12 volts whenever the Letterbox aspect 
    ratio is chosen. The output stops if PIP is enabled (PIP source is set to anything 
    other than off). 
    						
    							Operation
    58 Planar PD8130/PD8150 Installation/Operation Manual
    PRELI
    MINAR
    Y
    •4:3 causes the port to output 12 volts whenever the 4:3 aspect ratio is chosen. 
    The output stops if PIP is enabled (PIP source is set to anything other than off).
    •4:3 Narrow causes the port to output 12 volts whenever the 4:3 Narrow 
    aspect ratio is chosen.  The output stops if PIP is enabled (that is, the PIP 
    source is set to anything other than off).
    •RS232 causes the port to output 12 volts when an RS232 screen trigger 1 “on” 
    command is received and stop when a trigger 1 “off” command is received. 
    The 12 volt output also stops when the projector is turned off.
    Trigger 2 (PD8150 only): Select Trigger 2 from the Control menu to configure the 
    Trigger 2 output. Trigger 2 operates identically to Trigger 1. 
    Remote Code Set: Select Remote Code Set from the Control menu to specify 
    the remote IR code set to which the PD8130/PD8150 responds. The default is 
    Set-1. Choose Set-2 if other equipment in the theater responds to commands 
    from the PD8130/PD8150 remote control in ways that are unexpected or 
    undesirable. 
    When you select a different remote code set on the PD8130/PD8150, you must 
    re-program the remote control unit to use that same code set. To do this, press 
    and hold the LIGHT and ENTER buttons simultaneously for approximately five 
    seconds. When the code set has changed, the remote control back-lighting 
    “blinks” to visually confirm the change.
    Table 6-1 lists the IR codes associated with each remote control button.
    Auto Source: This control chooses whether or not to scan for other active 
    sources if the current source is not available. The default setting is Off. 
    						
    							Operation
    Planar PD8130/PD8150 Installation/Operation Manual 59 
    PRELI
    MINAR
    Y
    LanguageSelect Language from the Main Menu to change the OSD Language. 
    The PD8130/PD8150 can display the menus in English, French, German, Italian, 
    Spanish, Swedish, Traditional Chinese, Simplified Chinese, Japanese, Korean, 
    Portuguese or Russian. 
    Press  or  to select a language. Then, press ENTER to confirm your selection. 
    						
    							Operation
    60 Planar PD8130/PD8150 Installation/Operation Manual
    PRELI
    MINAR
    Y
    ServiceAccess the Service Menu, shown in Figure 4-15, to view information that 
    uniquely identifies your projector and indicates its current operational status:
    •Model Name
    •Unit Serial Number
    •Software Version
    •Active/PIP Source
    •Pixel Clock
    •Signal Format
    •H/V Refresh Rate
    •Lamp Hours (number of lamp hours elapsed since the last reset)
    Should you ever need to contact Planar Technical Support, this information will 
    help them answer your questions and/or resolve product performance issues. 
    Figure 4-15. PD8130/PD8150 Service Menu
    You can also perform various maintenance tasks, such as resetting the lamp 
    hour counter, from this menu. 
    ➤ 
    						
    							Operation
    Planar PD8130/PD8150 Installation/Operation Manual 61 
    PRELI
    MINAR
    Y
    Lamp Hour Reset: When you replace the projector lamp (refer to Lamp 
    Replacement on page 63), you should also reset the lamp hour counter. To do 
    this, select Lamp Hour Reset from the Service menu, then press ENTER. Press 
    ENTER again to confirm the reset. Or, to cancel the operation, press  on the 
    remote to highlight No, then press ENTER.
    Factory Reset: Select Factory Reset from the Service menu to restore all 
    projector settings – except those listed below – to their factory-default values:
    •Lamp Hours
    • User Memory 1 / User Memory 2
    •ISF Day
    •ISF Night
    • Model Name / Serial Number
    •Language
    Blue Only: This feature removes all red and green color information from the 
    image, and is useful for color-calibrating the projector or other video 
    components. 
    Test Patterns: The PD8130/PD8150 has numerous internal test patterns that are 
    useful to technicians for advanced calibration, measurement and fault isolation 
    purposes. To access them, select 
    Test Patterns from the Service menu and set it 
    to On. 
    The available test patterns are:
    •White
    •Black
    •Red
    •Green
    •Blue
    •Cyan
    •Magenta
    • Yellow
    • ANSI Checkerboard
    • Horizontal Gray Ramp
    •Focus Grid
    Press  or  on the remote control unit or built-in keypad to cycle through the 
    test patterns. 
    Reset the Lamp Hour counter ONLY after you replace the 
    lamp. Otherwise, the reported “Lamp Hours” will be 
    inaccurate. 
    Do not exceed the recommended lamp life. An old lamp 
    becomes increasingly fragile and prone to sudden failure.
    Note
    WARNING 
    						
    							Operation
    62 Planar PD8130/PD8150 Installation/Operation Manual
    PRELI
    MINAR
    Y
    To turn test patterns off, press any key other than  or  on the remote control 
    unit or built-in keypad.
    Altitude: Select Altitude from the Service Menu to control the operation of the 
    projector’s cooling fan. 
    In most cases, the default setting (Auto) will maintain the correct operating 
    temperature. If the lamp frequently turns off due to overheating, or in certain 
    high-altitude operating environments, you may need to change this setting to 
    High. 
    The OSD menus are not available when in “test pattern” 
    mode.Note 
    						
    							Maintenance and Troubleshooting
    Planar PD8130/PD8150 Installation/Operation Manual 63 
    PRELI
    MINAR
    Y
    5.1 
    Lamp Replacement
    The lamp should be replaced when it reaches the end of its life (typically 
    between 2000 and 4000 hours depending on the 
    Lamp Power setting), or 
    sooner if a noticeable degradation in brightness occurs. Contact your Planar 
    dealer to obtain a replacement lamp.
    1. Turn off the projector and unplug the power cord. Allow the projector to 
    cool down for approximately 60 minutes prior to removing the lamp 
    assembly for replacement. 
    2. Using a flat-blade screwdriver, 
    loosen the two screws holding the 
    rear compartment cover in place.
     
     
     
     
    3. Remove the rear compartment 
    cover by tilting it upward. 
     
     
     
     
     
     
     
     
    4. Loosen the screw on the lamp 
    cover and pull the lamp cover 
    out.
     
     
    5. Loosen the two screws on the 
    lamp module.
     
     
     
     
    6. Pull the lamp module handle 
    firmly to remove the lamp 
    module. 
    7. Perform Steps 6 through 2 (in 
    reverse order) to install the new 
    lamp module. 
    8. Turn on the power and reset the 
    lamp timer. 
    5. Maintenance and Troubleshooting
    
    
    
    
    
    
     
    						
    							Maintenance and Troubleshooting
    64 Planar PD8130/PD8150 Installation/Operation Manual
    PRELI
    MINAR
    Y
    5.2 
    Troubleshooting Tips
    Table 5-1 provides some general guidelines for troubleshooting problems you 
    may encounter with the PD8130/PD8150. If the suggested solutions fail to resolve 
    the problem or if you encounter an issue not described here, please contact 
    Planar Technical Support. 
    Table 5-1. Troubleshooting Chart 
    SymptomPossible Cause(s)Solution
    The projector does not 
    turn on. • The PD8130/PD8150 is 
    not plugged in or the 
    AC outlet is not active.  
    •Lamp cover is not 
    securely attached. • Ensure that the 
    PD8130/PD8150 is 
    plugged in and that the 
    AC outlet is active. 
    • Securely attach the 
    lamp cover.
    The projector does not 
    turn back on after it was 
    powered off. • The projector will not 
    turn on for two minutes 
    after power-off, to 
    protect the lamp. • Wait until the 
    PD8130/PD8150 
    completes its 
    cool-down (POWER LED 
    lights solid green). 
    The remote control does 
    not work correctly. • The batteries have run 
    out. 
    • IR code set mismatch 
    between remote 
    control unit and 
    projector. • Replace the batteries.  
    • Press and hold the 
    LIGHT and ENTER 
    remote control buttons 
    simultaneously until the 
    remote control 
    back-lighting “blinks” 
    (approximately five 
    seconds). Then, try 
    again. 
    The projector is on and 
    OSD menus appear, but 
    there is no video image 
    on-screen. • Incorrect source 
    selection.
    • Source component is 
    not turned on. 
    • Source component is 
    connected incorrectly 
    or not at all. • Select the correct 
    source. 
    • Turn on the source.  
    • Check cable 
    connection from 
    source component to 
    projector. 
    A projected image from a 
    DVD is split or otherwise 
    scrambled. • DVD player is 
    connected to the 
    Component input and 
    set to progressive scan 
    mode. • Turn off progressive 
    scan on the DVD 
    player. 
    Image is blurred. • The lens is not correctly 
    focused. • Adjust the focus with 
    the remote control. 
    Image is too bright and/or 
    lacks definition in the 
    bright areas of the image. • Contrast is set too high. • Lower the contrast 
    setting.  
    						
    							Maintenance and Troubleshooting
    Planar PD8130/PD8150 Installation/Operation Manual 65 
    PRELI
    MINAR
    Y
    Image appears “washed 
    out” and/or dark areas 
    appear too bright. • Brightness is set too 
    high.• Lower the brightness 
    setting. 
    Colors in the image are 
    swapped; for example, 
    reds appear blue or vice 
    versa. • The Red/Pr, Green/Y or 
    Blue/Pb outputs from 
    the source are 
    connected to the 
    wrong inputs on the 
    PD8130/PD8150.• Ensure that the source 
    outputs are connected 
    to the correct 
    PD8130/PD8150 input. 
    LED is flashing alternating 
    green and red. • The lamp cover is open.
    • The lamp has failed or 
    exceeded its usage life.• Close the lamp cover.
    • Replace the lamp with 
    a new one. 
    LED is flashing red. • PD8130/PD8150 internal 
    temperature is too high.• Power off the 
    PD8130/PD8150 and 
    allow it to cool down. 
    Ensure that the intake 
    and exhaust vents are 
    not blocked. Turn the 
    projector back on. If 
    the problem persists, 
    please contact Planar 
    Technical Support for 
    assistance. 
    LED lights solid red.•Fans are not working 
    properly or power-on 
    self-test has failed.• Please contact Planar 
    Technical Support for 
    assistance. 
    Table 5-1. Troubleshooting Chart (continued)
    Symptom Possible Cause(s) Solution 
    						
    							Maintenance and Troubleshooting
    66 Planar PD8130/PD8150 Installation/Operation Manual
    PRELI
    MINAR
    Y
    Notes: 
    						