Philips Trim 1 Service Manual
Here you can view all the pages of manual Philips Trim 1 Service Manual. The Philips manuals for Cardiograph are available online for free. You can easily download all the documents as PDF.
Page 11
1 1-1 Chapter 1Introduction This PageWriter Trim I, II, III, Rx Cardiograph Service Manual provides the information you need to successfully service the PageWriter Trim cardiographs with software version A.01.03 and higher. The PageWriter Trim Cardiograph product family includes the following four product models as described in Table 1-1. This Service Manual includes information on: „Theory of operation „Maintenance procedures „Performance verification and safety testing „Repairs „Ordering parts and...
Page 12
IntroductionWho Should Use this Manual 1-2PageWriter Trim Cardiograph Service Manual Who Should Use this Manual This manual is intended for users who handle preventive maintenance, periodic operational checks, and basic troubleshooting for PageWriter Trim cardiographs. Before attempting to service the cardiographs, you must review the following documentation and training materials: „PageWriter Trim Instructions for Use „PageWriter Trim Cardiograph Interactive Training Program „This Service Manual...
Page 13
IntroductionSafety Summary PageWriter Trim Cardiograph Service Manual1-3 Safety Summary Safety Symbols Marked on the Cardiograph Symbol Name Description Attention See PageWriter Trim Instructions for Use for information. Type CF ECG physio isolation is type CF, defibrillator proof. Electrical leakage current is suitable for all patient applications including direct cardiac application. Alternating current Indicates that the cardiograph is receiving alternating currents. On/Standby Pressing the...
Page 14
IntroductionSafety Summary 1-4PageWriter Trim Cardiograph Service Manual Global Medical Device Nomenclature CodeGlobal Medical Device Nomenclature Code is a 5-digit code providing a brief description of the device, as defined by EN ISO 15225. Safety Symbols Marked on the Cardiograph (continued) Symbol Name Description Safety Symbols Marked on the Cardiograph Packaging Symbol Description Keep dry. Ambient temperature range of 0 oC (32o.F) to 50 oC (122o F) (non-condensing) for transport and...
Page 15
IntroductionImportant Patient and Safety Information PageWriter Trim Cardiograph Service Manual1-5 Important Patient and Safety Information The PageWriter Trim cardiograph isolates all connections to the patient from electrical ground and all other conductive circuits in the cardiograph. This reduces the possibility of hazardous currents passing from the cardiograph through the patient’s heart to ground, and from other equipment connected to the patient passing through the leads into the cardiograph...
Page 16
IntroductionImportant Patient and Safety Information 1-6PageWriter Trim Cardiograph Service Manual WARNINGThe Welsh bulb electrodes (available as an accessory for the cardiograph) do not meet the requirements of IEC 60601-2-25 for defibrillation recovery time, and cannot be reliably used for immediate patient diagnosis following defibrillation. WARNINGThe PageWriter Trim I cardiograph is not recommended for diagnostic cardiograph use during defibrillation. It does not provide real-time data in less...
Page 17
IntroductionImportant Patient and Safety Information PageWriter Trim Cardiograph Service Manual1-7 „The use of equipment that applies high frequency voltages to the patient (including electrosurgical equipment and some respiration transducers) is not supported and may produce undesired results. Disconnect the patient data cable from the cardiograph, or detach the leads from the patient prior to performing any procedure that uses high frequency surgical equipment. „Do not perform ST analysis on the...
Page 18
IntroductionImportant Patient and Safety Information 1-8PageWriter Trim Cardiograph Service Manual „Portable medical equipment such as X-rays and MRI may produce electromagnetic interference that produces noise in the ECG signal. Move the cardiograph away from these potential sources of electromagnetic interference. „Do not pull on the paper while an ECG report is being printed. This can cause distortion of the waveform and can lead to potential misdiagnosis. „Only use the Philips Medical Systems AC...
Page 19
IntroductionThe PageWriter Trim Cardiograph PageWriter Trim Cardiograph Service Manual1-9 „The combined maximum weight that can be placed on the cardiograph cart shelf and the top surface of the cart cannot exceed 20 kg (44 lbs). Do not place more than the specified weight on the cardiograph top surface and shelf. „Do not connect any device to the RS-232 port on the rear of the cardiograph when the patient data cable is connected to a patient. „There are no cardiograph parts that can be sterilized....
Page 20
IntroductionThe Philips 12-Lead Algorithm 1-10PageWriter Trim Cardiograph Service Manual Indications for Use The cardiograph is to be used where the clinician decides to evaluate the electrocardiogram of adult and pediatric patients as part of decisions regarding possible diagnosis, potential treatment, effectiveness of treatment, or to rule out causes for symptoms. The Philips 12-Lead Algorithm The PageWriter Trim Cardiograph software uses the Philips 12-Lead Algorithm. The algorithm in the software...