Mounting board Ceiling board Mounting board Ceiling board 2Setting up the Mounting board. For suspended ceilings (1) Prepare a Mounting board long enough to span the distance between the C-beams, and cut a φ60 mm {2-3/8”} hole in it that matches the hole in the ceiling. (2) Use the template (provided) to cut four φ6 mm {1/4”} holes (in four positions) in the mounting board. For structurally strong ceilings Prepare the mounting board by cutting a φ60 mm {2-3/8”} hole in it. FEATURES Ceiling Mount Bracket Instructions Model Nos.WV-Q117/WV-Q117E AM0205-0 3TR003442AAA Printed in Japan C beam M beam60 mm in diameter {2-3/8”}Ceiling1Decide where to install the camera and open aφ60 mm {2-3/8”} hole in the ceiling. INSTALLATION 3Attach the Ceiling Mount Ring (provided) to the Mounting board Screws are not provided. Align it with the position the camera will be installed.7For suspended ceilings7For structurally strong ceilings Ceiling Mount Ring (provided) Ceiling Mount Ring (provided) M4 Screws (not provided)Wood screws (not provided) The Ceiling Mount Bracket WV-Q117 is used to mount the Combination Camera WV-CS950 or WV-CS954 on a ceiling.Before attempting to connect or install this product, please read these instructions carefully and save this manual for future use. • Fasten the bracket to a ceiling strong enough to support the camera weight (approx. 2.9 kg {6.38 lbs}). • Wipe the bracket regularly using a soft and dry cloth, or a cloth moistened with a water solution of an ordinary kitchen detergent. • Do not use chemicals for cleaning the enclo- sure as it may damage the surface. • All the necessary steps required for installing this product must be taken by a qualified ser- vice person or system installer. PRECAUTIONS • Be sure to use the aniti-fall wire. • Do not use this branket with any equipment other than the WV-CS950 and the WV-CS954. • Follow all applicable local and national elec- trical, fire and safety codes when installing the camera with this ceiling mount bracket. The model numbers in this Operating Instruc- tions are shown without suffix. 15° Mounting Screw Rotate Remove the Camera Mounting Base by pulling up. 4Installing the Mounting board. For suspended ceilings Align it with the hole in the ceiling and lay it across the two C-beams. For structurally strong ceilings Align it with the hole in the ceiling and attach it. 5Remove the Mounting Screw (M3, provided), pull up the Camera Mounting Base off the camera, and turn the camera counterclock- wise. Lock Lug Fixing Screws L-type Base Lug (provided)Lock Lug Lock Lug Fixing Screws 6Remove the two Lock Lug Fixing Screws and replace the Lock Lug with L-type. Retighten the two Lock Lug Fixing Screws (refer to the right figure). UT+O//5?C .3,0,0/.825 Z8/
Camera Mounting Base M4-L8 Screws (provided) 8Pass the power cord and video cables of the Camera Mounting Base through the hole in this bracket, and fasten it to the bracket with the four M4-L8 Screws (provided). Nut (M4, provided) *1 Use two nuts. *2 Fasten finally.Ceiling Slot Masking Cover (provided) M3 Screw (provided)*2 Hexagon Socket Head Screw (M4, provided)9Fit the Slot Masking Cover (provided) over the bracket, insert the Hexagon Socket Head Screws (M3, provided) into their holes, and fasten the Ceiling Mount Ring (provided) with the two nuts (M3, provided). Instructions for the Fall Prevention Clip (provided) 1. Remove the Fall Prevention Wire from the Fall Prevention Clip. 2. Insert anchor bolt from side . 3. Fold side down over side . 4. Suspend the Fall Prevention Angle Clip from the other end of the Fall Prevention Wire. above 1 Insert 2 Remove Fall Prevention Wire SideSide Anchor Bolt 4 Anchor Bolt Spacer nuts Existing anchor bolt Fall Prevention Clip (provided) Fall Prevention Clip (provided) Fall Prevention Wire (provided) 3 fold down below 13Attach the Fall Prevention Clip (provided) to the anchor bolt. Attach the Fall Prevention (provided) to the bracket and the Fall Prevention Angle Clip. Note:Two spacer nuts are necessary for the anchor bolt. Heat insulator (provided) Heat insulator (provided)14Cover the bracket with the Heat Insulator (provided). * The bracket is not shown in the illustrations. Ring of the Fall Prevention Wire10Suspend the Fall Prevention Wire for the camera from the Camera Mounting Base. Note:Make sure that the wire matches the Fall Prevention Wire Fixing Angle. 15Ã Rotate Camera Mounting Bracket L-type Lock Lug (provided) Mounting Screw 11Attach the camera to the Camera Mounting Base, turn the camera clockwise, and tighten the Mounting Screw (M3, provid- ed). Decoration Cover Slot Masking Cover (provided)12Place the Decoration Cover for the bracket on the camera. Then, pull up the Slot Masking Cover (provided).Ambient Operating Temperature: 10˚C - +50˚C {14˚F – 122˚F} Dimensions: 120 (diameter) ×202 (D) mm {4-3/4” (diameter) ×7-61/64” (D) mm} Weight: 720 g{1.59 lbs} Weight and dimensions indicated are approximate. Specifications are subject to change without notice. SPECIFICATIONS STANDARD ACCESSORIES Fall Protection Wire ..........................................1 pc. Fall Prevention Clip ..........................................1 pc. Ceiling Mounting Ring .....................................1 pc. L-type Base Lug ..............................................1 pc. L-type Lock Lug...............................................1 pc. Slot Masking Cover..........................................1 pc. Hexagon Socket Head Screw (M4) ...............2 pcs.Wrench for Hexagon Socket Head Screw .......1 pc. Nut (M4) .........................................................4 pcs. Screw (M3).....................................................2 pcs. Screw (M4-L8) ...............................................4 pcs. Template ..........................................................1 pc. Heat Insulator ..................................................1 pc. © 2005 Matsushita Electric Industrial Co., Ltd. All rights reserved. Lock Lug Fixing Screws Lock Lug L-type Lock Lug (provided)7Remove the two Lock Lug Fixing Screws and replace the Lock Lug with L-type. Retighten the two Lock Lug Fixing Screws (refer to the right figure). For European and other fields: Matsushita Electric Industrial Co., Ltd. Osaka, Japan http://www.panasonic.co.jp/global/ For U.S. , Canadian and Puerto Rican fields: Panasonic System Solutions Company, Unit Company of Panasonic Corporation of North America Security Systems www.panasonic.com/security For customer support, call 1.877.733.3689 Executive Office:Three Panasonic Way 2H-2, Secaucus, New Jersey 07094 Zone Office Eastern:Three Panasonic Way, Secaucus, New Jersey 07094 Central:1707 N. Randal Road, Elgin, IL 60123 Southern:1225 Northbrook Parkway, Suwanee, GA 30024 Western:6550 Katella Ave., Cypress, CA 90630Panasonic Canada Inc. 5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905) 624-5010 http://www.panasonic.ca Panasonic Sales Company Division of Panasonic Puerto Rico Inc. San Gabriel Industrial Park 65th Infantry Ave. KM. 9.5 Carolina, P.R. 00985 (809) 750-4300 UT+O//5?C .3,0,0/08.. Z81