41 ..............................................................................................................................Note When the HTTP port number has been changed from 80, enter http://IP address of the camera:port number. When the DDNS function has been set to ON, enter http://host name registered to DDNS server.nmdns.net/. When this camera is to be used in a local area network, configure the web browser to bypass the proxy server for the local address. ................................................................................................................................... Important The default user name is admin and default password is 12345. To enhance the security, be sure to change the password for the user name admin. (→Setup Manual) When displaying multiple MPEG-4 images on a PC, images sometimes cannot be displayed depending on the performance of the PC. For details on the required PC environment, refer to page 6. Monitor images from multiple cameras Images from multiple cameras can be displayed on a multi-screen. 4 cameras can be registered as a group, and camera images for up to 8 cameras (2 groups) can be displayed simultaneously in a multi-screen. For further information about registering cameras, refer to the Setup Manual. Important Only JPEG images can be displayed on a multi-screen. When the power is turned off or the LAN cable is disconnected when displaying images, displaying images on a multi-screen from the Live page will become unavailable.
Monitor Images on a PC (continued) 42 Multi-screen window 1Click the [Multi-screen] button. Images from the camera are displayed in four screens. Click a camera title. Live images from the camera corresponding to the clicked camera title will be displayed on the Live page of the newly opened window. 1 To display images on a single screen, click the [Live] button.
43 Action at an alarm occurrence When a Terminal alarm, VMD alarm, Scene change detection alarm or Command alarm occurs, alarm action is performed according to the setup for that alarm. For further information about how to set alarms, refer to the Setup Manual. Alarm type Action at an alarm occurrence Display of the [Alarm occurrence indication] button on the Live page (→Setup Manual) Terminal alarm : Alarm action will be performed when the alarm device connected to the cable is activated. VMD alarm : Alarm action will be performed when a change (i.e. motion) is detected in the image in the set VMD area. * VMD stands for Video Motion Detector. Scene change detection alarm: Alarm action will be performed when this camera has been interfered with, for example, when it has been covered with a cloth or when its direction has been changed. Command alarm : Alarm action will be performed when a Panasonic alarm notice is received from a connected device via the network. The [Alarm occurrence indication] button will be displayed and will blink on the Live page when an alarm occurs.
Action at an alarm occurrence (continued) 44 Important When Polling(30 sec) is selected for Alarm status update mode, the alarm occurrence indication button will be refreshed in 30-second intervals. For this reason, it may take a maximum of 30 seconds until the alarm occurrence indication button is displayed on the Live page when an alarm occurs. (→Setup Manual)
45 Viewing Help If you want to know anything about operation or setup methods on screen, display the Help screen. Displaying the Help screen Setup screen Help screen 1Click the [Setup] button. The setup screen is displayed. 2Click the [Help] button. The Help screen is displayed. 1 2 Click the desired item to display a detailed explanation for the corresponding operation.
46 Troubleshooting Before requesting service, check the following items. Also, check the description in the Operating Instructions, Setup Manual. Contact your dealer if a problem cannot be solved even after checking and trying the solution or if a problem is not described below. SymptomsCheck item/remedypage Camera does not turn on.▲ AC/DC power supply Is the power firmly connected to the power outlet? Make sure that it is connected.— PoE power supply Is the network cable connected to a PoE- compatible power supply unit by an Ethernet (Category 5) cable? Make sure that it is connected. 34 Some power supply units that can connect multiple PoE terminal devices are not supplied with power when the total power supply limitation is exceeded. — Read the Operating Instructions of the PoE power supply unit.—
47 Specifications General Camera Power supply 24 V AC, 60 Hz, 12 V DC, PoE (IEEE802.3af-compliant) Power consumption 24 V AC: approx. 8.2 W, 12 V DC: approx. 850 mA, PoE: approx. 9.2 W (Class 0) (When heater unit is used) 24 V AC: approx. 16 W, 12 V DC: approx. 920 mA, PoE: approx. 12 W (Class 0) Ambient operating tempera- ture-10ºC to +50ºC {14ºF to 122ºF} (When heater unit is used) -30ºC to +50ºC {-22ºF to 122ºF} (AC 24 V or PoE) Ambient operating humidity Less than 90% (non-condensation) Water Resistance Camera unit: IEC60529 (IP66, Against ingress of water with harmful effects powerful jetting) * Only on condition that installation specified in this document and appropriate waterproofing is conducted correctly Monitor output VBS: 1.0 V [P-P]/75 Ω (NTSC), composite signal, RCA jack External I/O terminals ALARM IN, ALRM OUT or DAY/NIGHT IN, AUX OUT Dimensions 159 mm (D) x 153 mm (H) {6-17/64(D) x 6-1/32(H)} Weight Approx. 1.9 kg (including bracket) {4.2 lbs} Finish Body: aluminum die cast, light silver Dome: smoke polycarbonate resin Pick-up device 1/3-inch interline transfer CCD Effective Pixels 768 (H) x 494 (V) Scanning Area 4.8 mm (H) x 3.6 mm (V) Scanning 2:1 interlace * Mounted with motion adaptive interlace/progressive conversion function for network output Minimum Illumination (SENSE UP: OFF, AGC: HIGH, F1.4, WIDE)1.5 lux {fc} (color), 0.16 lux {fc} (black and white) (When optional clear dome is used.) 0.6 lux {fc} (color), 0.08 lux {fc} (black and white) Dynamic range 52 dB typ. (Super Dynamic III ON, shutter speed OFF) Gain ON (LOW), ON (MID), ON (HIGH), OFF
Specifications (continued) 48 Lens Network Shutter speed OFF (1/60), AUTO, 1/100 Electronic sensitivity enhancementMax. 32X White balance ATW1/ATW2/AWC Digital noise reduction LOW/HIGH Electronic zoom Max. 3X Camera title Max. 16 character display (alphanumeric characters, marks) ON/OFF VMD alarm 4 areas settable Scene change detection alarmON (LOW), ON (MID), ON (HIGH), OFF Privacy zone ON/OFF (max. 8 zone settings) Type 2x variable focal lens Focal length f=3.8 mm - 8.0 mm F number F1.4 - 1.8, close Focus range∞ - 1.2 m Angle of view Horizontal:73.6°(WIDE) - 35.6°(TELE) Vertical:53.4°(WIDE) - 26.6°(TELE) Adjusting angle Panning range: ±175° Tilting range: ±75° Azimuth range: ±160° Network 10BASE-T/100BASE-TX, RJ45 connector Image resolution VGA (640 x 480)/QVGA (320 x 240) Image compression systemMPEG-4 Image selection: motion priority/standard/quality priority Transmission type: Unicast/Multicast JPEG Quality selection: 0 highest quality/1 high quality/2/3/4/5 standard/6/7/8/9 low quality (in ten stages, 0 to 9) Transmission type: PULL/PUSH Refresh interval 0.1 fps to 30 fps (JPEG frame rate limited at JPEG/MPEG- 4 simultaneous operation) Total bit rate Unlimited/64 kbps/128 kbps/256 kbps/ 512 kbps/1024 kbps/2048 kbps/4096 kbps Supported protocol TCP/IP, UDP/IP, HTTP, RTP, FTP, SMTP, DHCP, DNS, DDNS, NTP, SNMP
49 Optional accessories Supported OS Windows ® 2000 Professional SP4, Windows® XP Home Edition SP2, Windows® XP Professional SP2 Supported browser Internet Explorer® 6.0 SP2, Internet Explorer® 7.0 * When supported OS is Windows® 2000 Professional SP4, Microsoft Internet Explorer® 6.0 SP1 Max. number of connected cameras8 (depending on conditions) FTP client Alarm image transmission, FTP periodic transmission Multi-screen Simultaneous display of images from 8 cameras (4 cameras x 2 groups) Operation confirmed SD memory cards (sold separately)Panasonic Size: 64 MB, 128 MB, 256 MB, 512 MB, 1 GB, 2 GB Heater unit WV-CW4H Weight, approx. 40 g Clear dome cover WV-CW4C Weight, approx. 110 g Ceiling Mount Bracket WV-Q169 Weight, approx. 705 g Accessories CD-ROM* . . . . . . . . . . . . . . . . . . . . . . .1 pc. Use the following items for installation work. Operating Instructions (this book) . . . . .1 pc. 4-pin Alarm Cable . . . . . . . . . . . . . . . . . 1 pc. Warranty Certificate . . . . . . . . . . . . . . . . . . 1RJ-45 female-female conversion connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 pc. Label (MAC address). . . . . . . . . . . . . . .1 pc. Mounting Bracket . . . . . . . . . . . . . . . . . 1 pc. Driver Bit . . . . . . . . . . . . . . . . . . . . . . . . 1 pc. Waterproof tape (butyl rubber tape) . . . 1 pc. * The CD-ROM contains the Panasonic IP Setup Software, viewer software Network Camera View3, and the Operating Manual/Setup Manual (PDF).
Panasonic System Solutions Company, Unit Company of Panasonic Corporation of North America Security Systems www.panasonic.com/security For customer support, call 1.877.733.3689 Executive Office: Three Panasonic Way 2H-2, Secaucus, New Jersey 07094 Zone Office Eastern: Three Panasonic Way, Secaucus, New Jersey 07094 Central: 1707 N. Randal Road, Elgin, IL 60123 Southern: 1225 Northbrook Parkway, Suwanee, GA 30024 Western: 6550 Katella Ave., Cypress, CA 90630 Panasonic Canada Inc. 5770 Ambler Drive,Mississauga, Ontario, L4W 2T3 Canada (905)624-5010 http://www.panasonic.ca Panasonic Sales Company Division of Panasonic Puerto Rico Inc. San Gabriel Industrial Park 65th Infantry Ave. KM. 9.5 Carolina P.R. 00985(809)750-4300 © 2007 Matsushita Electric Industrial Co., Ltd. All Rights Reserved. AM0307-2057 3TR005032CAA Printed in Japan