Home > Panasonic > Camera > Panasonic Wv Nw484s Operating Instructions Manual

Panasonic Wv Nw484s Operating Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Wv Nw484s Operating Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							41
    ..............................................................................................................................Note
     When the HTTP port number has been changed from 80, enter http://IP address of 
    the camera:port number.
     When the DDNS function has been set to ON, enter http://host name registered to 
    DDNS server.nmdns.net/.
     When this camera is to be used in a local area network, configure the web browser to 
    bypass the proxy server for the local address.
    ...................................................................................................................................
    Important
     The default user name is admin and default password is 12345. 
    To enhance the security, be sure to change the password for the user name admin. 
    (→Setup Manual)
     When displaying multiple MPEG-4 images on a PC, images sometimes cannot be 
    displayed depending on the performance of the PC. 
    For details on the required PC environment, refer to page 6.
    Monitor images from multiple cameras
    Images from multiple cameras can be displayed on a multi-screen. 4 cameras can be 
    registered as a group, and camera images for up to 8 cameras (2 groups) can be displayed 
    simultaneously in a multi-screen. For further information about registering cameras, refer to 
    the Setup Manual.
    Important
     Only JPEG images can be displayed on a multi-screen.
     When the power is turned off or the LAN cable is disconnected when displaying images, 
    displaying images on a multi-screen from the Live page will become unavailable. 
    						
    							Monitor Images on a PC (continued)
    42
     Multi-screen window
    1Click the [Multi-screen] button. 
    Images from the camera are displayed in 
    four screens. 
    Click a camera title. Live images from 
    the camera corresponding to the 
    clicked camera title will be displayed 
    on the Live page of the newly opened 
    window. 
    1
    To display images on a single 
    screen, click the [Live] button.  
    						
    							43
    Action at an alarm occurrence 
    When a Terminal alarm, VMD alarm, Scene change detection alarm or Command 
    alarm occurs, alarm action is performed according to the setup for that alarm. For further 
    information about how to set alarms, refer to the Setup Manual.
    Alarm type
    Action at an alarm occurrence
     Display of the [Alarm occurrence indication] button on the Live page (→Setup 
    Manual) Terminal alarm : Alarm action will be performed when the alarm device connected 
    to the cable is activated.
    VMD alarm : Alarm action will be performed when a change (i.e. motion) is 
    detected in the image in the set VMD area. 
    * VMD stands for Video Motion Detector.
    Scene change 
    detection alarm: Alarm action will be performed when this camera has been 
    interfered with, for example, when it has been covered with a 
    cloth or when its direction has been changed.
    Command alarm : Alarm action will be performed when a Panasonic alarm notice is 
    received from a connected device via the network.
    The [Alarm occurrence indication] button will be 
    displayed and will blink on the Live page when 
    an alarm occurs. 
    						
    							Action at an alarm occurrence (continued)
    44
    Important
     When Polling(30 sec) is selected for Alarm status update mode, the alarm 
    occurrence indication button will be refreshed in 30-second intervals. For this reason, it 
    may take a maximum of 30 seconds until the alarm occurrence indication button is 
    displayed on the Live page when an alarm occurs. (→Setup Manual) 
    						
    							45
    Viewing Help 
    If you want to know anything about operation or setup methods on screen, display the 
    Help screen.
    Displaying the Help screen
     Setup screen 
     Help screen
    1Click the [Setup] button. 
    The setup screen is displayed.
    2Click the [Help] button. 
    The Help screen is displayed.
    1
    2
    Click the desired item to display a 
    detailed explanation for the 
    corresponding operation.  
    						
    							46
    Troubleshooting 
    Before requesting service, check the following items.
    Also, check the description in the Operating Instructions, Setup Manual.
    Contact your dealer if a problem cannot be solved even after checking and trying the 
    solution or if a problem is not described below.
    SymptomsCheck item/remedypage
    Camera does not 
    turn on.▲
    AC/DC power supply 
     Is the power firmly connected to the power 
    outlet? 
    Make sure that it is connected.—
    PoE power supply 
     Is the network cable connected to a PoE-
    compatible power supply unit by an 
    Ethernet (Category 5) cable? 
    Make sure that it is connected. 34
     Some power supply units that can connect 
    multiple PoE terminal devices are not 
    supplied with power when the total power 
    supply limitation is exceeded. —
     Read the Operating Instructions of the PoE 
    power supply unit.— 
    						
    							47
    Specifications 
     General
     Camera Power supply 24 V AC, 60 Hz, 12 V DC, PoE (IEEE802.3af-compliant)
    Power consumption 24 V AC: approx. 8.2 W, 
    12 V DC: approx. 850 mA, 
    PoE: approx. 9.2 W (Class 0)
    (When heater unit is used)
    24 V AC: approx. 16 W, 
    12 V DC: approx. 920 mA, 
    PoE: approx. 12 W (Class 0)
    Ambient operating tempera-
    ture-10ºC to +50ºC {14ºF to 122ºF}
    (When heater unit is used)
    -30ºC to +50ºC {-22ºF to 122ºF} (AC 24 V or PoE)
    Ambient operating humidity Less than 90% (non-condensation)
    Water Resistance Camera unit: IEC60529 (IP66, Against ingress of water 
    with harmful effects powerful jetting)
    * Only on condition that installation specified in this 
    document and appropriate waterproofing is conducted 
    correctly
    Monitor output VBS: 1.0 V [P-P]/75 Ω (NTSC), composite signal, RCA 
    jack
    External I/O terminals ALARM IN, ALRM OUT or DAY/NIGHT IN, AUX OUT
    Dimensions 159 mm (D) x 153 mm (H) {6-17/64(D) x 6-1/32(H)}
    Weight Approx. 1.9 kg (including bracket) {4.2 lbs}
    Finish Body: aluminum die cast, light silver
    Dome: smoke polycarbonate resin
    Pick-up device 1/3-inch interline transfer CCD
    Effective Pixels 768 (H) x 494 (V)
    Scanning Area 4.8 mm (H) x 3.6 mm (V)
    Scanning 2:1 interlace
    * Mounted with motion adaptive interlace/progressive 
    conversion function for network output
    Minimum Illumination 
    (SENSE UP: OFF, 
    AGC: HIGH, F1.4, WIDE)1.5 lux {fc} (color), 0.16 lux {fc} (black and white)
    (When optional clear dome is used.)
    0.6 lux {fc} (color), 0.08 lux {fc} (black and white)
    Dynamic range 52 dB typ. (Super Dynamic 
    III ON, shutter speed OFF)
    Gain ON (LOW), ON (MID), ON (HIGH), OFF 
    						
    							Specifications (continued)
    48
    Lens
    Network Shutter speed OFF (1/60), AUTO, 1/100
    Electronic sensitivity 
    enhancementMax. 32X
    White balance ATW1/ATW2/AWC
    Digital noise reduction LOW/HIGH
    Electronic zoom Max. 3X
    Camera title Max. 16 character display (alphanumeric characters, 
    marks) ON/OFF
    VMD alarm 4 areas settable
    Scene change detection 
    alarmON (LOW), ON (MID), ON (HIGH), OFF
    Privacy zone ON/OFF (max. 8 zone settings)
    Type 2x variable focal lens
    Focal length f=3.8 mm - 8.0 mm
    F number F1.4 - 1.8, close
    Focus range∞ - 1.2 m
    Angle of view Horizontal:73.6°(WIDE) - 35.6°(TELE) 
    Vertical:53.4°(WIDE) - 26.6°(TELE)
    Adjusting angle Panning range: ±175° 
    Tilting range: ±75° 
    Azimuth range: ±160°
    Network 10BASE-T/100BASE-TX, RJ45 connector
    Image resolution VGA (640 x 480)/QVGA (320 x 240)
    Image 
    compression 
    systemMPEG-4 Image selection: motion priority/standard/quality priority 
    Transmission type: Unicast/Multicast
    JPEG Quality selection: 0 highest quality/1 high quality/2/3/4/5 
    standard/6/7/8/9 low quality (in ten stages, 0 to 9) 
    Transmission type: PULL/PUSH
    Refresh interval 0.1 fps to 30 fps (JPEG frame rate limited at JPEG/MPEG-
    4 simultaneous operation)
    Total bit rate Unlimited/64 kbps/128 kbps/256 kbps/ 
    512 kbps/1024 kbps/2048 kbps/4096 kbps
    Supported protocol TCP/IP, UDP/IP, HTTP, RTP, FTP, SMTP, DHCP, DNS, 
    DDNS, NTP, SNMP 
    						
    							49
     Optional accessories Supported OS Windows
    ® 2000 Professional SP4, 
    Windows® XP Home Edition SP2, 
    Windows® XP Professional SP2
    Supported browser Internet Explorer® 6.0 SP2, 
    Internet Explorer® 7.0
    * When supported OS is Windows® 2000 Professional 
    SP4, Microsoft Internet Explorer® 6.0 SP1
    Max. number of connected 
    cameras8 (depending on conditions)
    FTP client Alarm image transmission, FTP periodic transmission
    Multi-screen Simultaneous display of images from 8 cameras 
    (4 cameras x 2 groups)
    Operation confirmed SD 
    memory cards (sold 
    separately)Panasonic 
    Size: 64 MB, 128 MB, 256 MB, 512 MB, 1 GB, 2 GB
    Heater unit WV-CW4H Weight, approx. 40 g
    Clear dome cover WV-CW4C Weight, approx. 110 g
    Ceiling Mount Bracket WV-Q169 Weight, approx. 705 g
    Accessories
    CD-ROM*  . . . . . . . . . . . . . . . . . . . . . . .1 pc. Use the following items for installation work.
    Operating Instructions (this book) . . . . .1 pc. 4-pin Alarm Cable . . . . . . . . . . . . . . . . . 1 pc.
    Warranty Certificate . . . . . . . . . . . . . . . . . .  1RJ-45 female-female conversion connector
     . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 pc.
    Label (MAC address). . . . . . . . . . . . . . .1 pc. Mounting Bracket  . . . . . . . . . . . . . . . . . 1 pc.
    Driver Bit . . . . . . . . . . . . . . . . . . . . . . . . 1 pc.
    Waterproof tape (butyl rubber tape)  . . . 1 pc.
    * The CD-ROM contains the Panasonic IP Setup Software, viewer software Network 
    Camera View3, and the Operating Manual/Setup Manual (PDF). 
    						
    							Panasonic System Solutions Company, 
    Unit Company of Panasonic Corporation of North America 
    Security Systems
    www.panasonic.com/security 
    For customer support, call 1.877.733.3689 
    Executive Office: Three Panasonic Way 2H-2, Secaucus, New 
    Jersey 07094 
    Zone Office 
    Eastern: Three Panasonic Way, Secaucus, New Jersey 07094 
    Central: 1707 N. Randal Road, Elgin, IL 60123 
    Southern: 1225 Northbrook Parkway, Suwanee, GA 30024 
    Western: 6550 Katella Ave., Cypress, CA 90630 Panasonic Canada Inc. 
    5770 Ambler Drive,Mississauga, 
    Ontario, L4W 2T3 Canada (905)624-5010
    http://www.panasonic.ca 
    Panasonic Sales Company 
    Division of Panasonic Puerto Rico Inc. 
    San Gabriel Industrial Park 65th Infantry Ave. KM. 9.5 Carolina
    P.R. 00985(809)750-4300 
    © 2007 Matsushita Electric Industrial Co., Ltd. All Rights Reserved.  AM0307-2057 3TR005032CAA Printed in Japan 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Wv Nw484s Operating Instructions Manual