    Have a look at the manual Panasonic VRF System Air Conditioner S 07mk2u6_s 09mk2u6_s 12mk2u6_s 12my2u6_s 18my2u6 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							11
    CHECK BEFORE REQUIRING SERVICES
    If your air conditioner still does not work properly although you checked the points as described above, first stop the operation and 
    turn off the power switch. Then contact your dealer and report the serial number and symptom. Never repair your air conditioner by 
    yourself since it is very dangerous for you to do so. You also report if the inspection mark   and the letters E, F, H, L, P in 
    combination with the numbers appear on the LCD of the remote controller.
    TIPS FOR ENERGY SAVING
    Avoid
     Do not block the air intake and outlet of the unit. If either is obstructed, the unit will not work well, and may be damaged.
     Do not let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the 
    sun, it will take longer to cool the room.
    Do
     Always try to keep the air filter clean. (Refer to “CARE AND CLEANING”.) A clogged filter will impair the performance of the unit.
     To prevent conditioned air from escaping, keep windows, doors and any other openings closed.
    Should the power fail while the unit is running
    If the power supply for this unit is temporarily cut off, the unit will automatically resume operation once power is restored using the 
    same settings before the power was interrupted.
    Symptom Cause Remedy
    Air conditioner does not run at 
    all although power is turned 
    on.Power failure or after power failure Press ON/OFF operation button on remote controller 
    again.
    Operation button is turned off.  Switch on power if breaker is turned off.
     If breaker has been tripped, consult your dealer 
    without turning it on.
    Fuse blow out. If blown out, consult your dealer.
    Poor cooling or heating 
    performanceAir intake or air discharge port of indoor 
    and outdoor units is clogged with dust or 
    obstacles.Remove dust or obstruction.
    Wind speed switch is set to “Low”. Change to “High” or “Strong”.
    Improper temperature settings Refer to “TIPS FOR ENERGY SAVING”.
    Room is exposed to direct sunlight in 
    cooling mode.
    Doors and /or windows are open.
    Air filter is clogged. Refer to “CARE AND CLEANING”.
    Too much heat sources in room in cooling 
    mode.Use minimum heat sources and in a short time.
    Too many people in room in cooling mode. Reduce temperature settings or change to “High” or 
    “Strong”.
    NOTE
    F569695_VRF_EN.fm  Page 11  Thursday, August 14, 2014  3:43 PM 
    						
    							12
    SPECIFICATIONS
    „4-Way Cassette 60x60
    * Values include the dimensions and weight of an optional ceiling panel.
    „Wall Mounted
    Model Name S-12MY2U6 S-18MY2U6
    Power Source 208 / 230 V, 60 Hz, 1PH
    Cooling CapacityBTU/h 12,000 19,000
    kW 3.5 5.6
    Heating CapacityBTU/h 14,000 21,000
    kW 4.1 6.2
    Sound Pressure Level 
    (H/M/L)dB(A)(Cooling) 36/34/32
    (Heating) 36/34/3040/37/34
    Unit Dimensions*H : inch (mm) 12-9/16 (319) 12-9/16 (319)
    W : inch (mm) 27-9/16 (700) 27-9/16 (700)
    D : inch (mm) 27-9/16 (700) 27-9/16 (700)
    Net Weight*
    lbs. (㎏)45.3 (20.4) 45.3 (20.4)
    Model Name S-07MK2U6 S-09MK2U6 S-12MK2U6
    Power Source 208 / 230 V, 60 Hz, 1PH
    Cooling CapacityBTU/h 7,500 9,600 12,000
    kW 2.2 2.8 3.5
    Heating CapacityBTU/h 8,500 11,000 14,000
    kW 2.5 3.2 4.1
    Sound Pressure Level 
    (H/M/L)dB(A) 36/33/29 37/34/29 40/36/29
    Unit DimensionsH : inch (mm) 11-7/16 (290) 11-7/16 (290) 11-7/16 (290)
    W : inch (mm) 34-9/32 (870) 34-9/32 (870) 34-9/32 (870)
    D : inch (mm) 8-7/16 (214) 8-7/16 (214) 8-7/16 (214)
    Net Weight
    lbs. (㎏)20 (9) 20 (9) 20 (9)
    F569695_VRF_EN.fm  Page 12  Thursday, August 14, 2014  3:43 PM 
    						
    							13
    MEMO
    F569695_VRF_EN.fm  Page 13  Thursday, August 14, 2014  3:43 PM 
    						
    							14
    MEMO
    F569695_VRF_EN.fm  Page 14  Thursday, August 14, 2014  3:43 PM 
    						
    							15
    MEMO
    F569695_VRF_EN.fm  Page 15  Thursday, August 14, 2014  3:43 PM 
    						
    							F569695
    BE0414-10814 © Panasonic Corporation 2014Printed in Malaysia 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic VRF System Air Conditioner S 07mk2u6_s 09mk2u6_s 12mk2u6_s 12my2u6_s 18my2u6 Operating Instructions