1 INSTALLATION INSTRUCTIONS Ventilating FanFV-20VQ3 FV-30VQ3 FV-40VQ3 Panasonic READ AND SAVE THESE INSTRUCTIONS. Please read these instructions carefully before attempting to install, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference. Table of Contents Supplied Accessories...
Page 2
2 SUPPLIED ACCESSORIES FV-20VQ3 FV-30VQ3 FV-40VQ3 Part name Appearance Quantity Grille 1 Suspension bracket setSuspension 4 bracket Rubber 1 4 Rubber 2 4 Rubber 3 4 Washer 8 Screw 8 Long screw 6 DESCRIPTION These Panasonic ceiling mount ventilating fan models use a low noise sirocco fan driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal-cutoff for safety. The grille covering the main body is a spring-loaded,...
Page 3
3 Model no. Air direction V HzPower consumption Speed Air deliver at Weight(W) (RPM) 0.1" WG (CFM) kg (lb.) FV-20VQ3 43.5 560 200 6.2 (13.6) FV-30VQ3 Exhaust 120 60 66.5 730 300 6.7 (14.7) FV-40VQ3 119 680 400 9.6 (21.1) *At 0.0" Static pressure, (Pa) DIMENSIONS FV-20VQ3 FV-30VQ3 FV-40VQ3 No. Part name No. Part name 1Grille5Body 2Adapter6Damper 3Junction box7Plug connector 4Junction box cover8Suspension bracket Dimensions: mm (inch) Model No.ABCDE F G H I FV-20VQ3 420 312 142 146 236 22...
Page 4
4 GENERAL SAFETY INFORMATION 1. Do not install this ventilating fan where air temperature may exceed 40°C. (104°F) 2. Make certain that the electric service supply voltage is 120V 60 Hz. 3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). 4. Always disconnect the power source before working on or near the fan, motor or junction box. 5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals,...
Page 5
5 INSTALLATION I (SUSPENDED CEILING) 1. Disconnect plug connector from receptacle before start- ing installation. 2. Assemble suspension bracket and rubber 1 to body. (Fig. 1) 3. Suspend body with anchor bolts. (not supplied) (Fig. 2) 4. Remove junction box cover and secure conduit to junc- tion box knockout hole. (7/8 inch) (Fig. 3) 5. Refer to wiring diagram Using wire nuts, connect house power wires to ventilat- ing fan wires (Fig. 3): black to black; white to white; green to greens....
Page 6
6 INSTALLATION II (WOODEN HEADER) 1. Install header between ceiling joists using nails or screws. (Fig. 5) 2. Install the ventilating fan to the header with long screws. (Figs. 5 & 6) Fig. 5 Fig. 6 Fig. 7 Ceiling joist Header AdapterCeiling joist Ventilating fan mm (inch) Model No. A B FV-20VQ3 315 454 FV-30VQ3 (12 13/32) (17 7/8) FV-40VQ3380 518 (15) (20 13/32) 3. Insert the circular duct to the adapter. Remove the junction box cover and secure conduit to junction box knockout hole....
Page 7
7 INSTALLATION III (IN EXISTING CONSTRUCTION) Installing the ventilating fan in an existing building requires an accessible area (attic or crawl space) above the planned installation location, or existing ducting and wiring. 1. To install the ventilating fan, follow the procedures described in Installation II. Take the following precautions before installation. CAUTION Check area above planned installation location to be sure that: 1. Duct work can be installed and that area is sufficient for proper...
Page 8
8 MAINTENANCE (CONT.) 3. Remove dust and dirt from fan body using a vacuum cleaner. (Fig. 10) Fig. 10 Fig. 11 Cleaner 4. Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with new cloth. (Fig. 11) 5. Replace grille. PRODUCT SERVICE Warning Concerning Removal of Covers. This unit should be serviced by qualified technicians only. No service information is provided for customers. Your product is designed and manufactured to ensure a minimum of...