Home > Panasonic > Ventilation > Panasonic Ventilation Fan Fv 05vs1 Installation Instructions

Panasonic Ventilation Fan Fv 05vs1 Installation Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Ventilation Fan Fv 05vs1 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Ventilating Fan
    FV-05VS1
    FV-08VS1
    READ AND SAVE THESE INSTRUCTIONS.R
    Please
    readthese
    instructionscarefullybeforeattempting
    toinstall,
    operate or service the Panasonic Ventilating Fan. Failure to comply
    with instructions could result in personal injury and/or property
    damage. Please retain this booklet for future reference.
    Description
    Dimensions
    Specifications
    Table of Contents
    Supplied Accessories
    Unpacking
    General Safety Information
    4
    4-54 32 2
    5
    Wiring Diagram
    13 12 8-9
    10
    10-11
    Installation( In Existing Construction )VI
    Installation( Wooden Header )V
    16
    16Maintenance
    Practical Guide to Installation
    16Product Service
    6-8IInstallation( Joist Mounting- )I
    Installation( Joist Mounting- )IIII
    ( -Joist Mounting )I InstallationIII
    Installation
    ( Between Joist Mounting )IV
    14-15
    IInstallation( Wall Installation- )IVI
    Installation( Wall Installation- )III VII
    Installation( Wall Installation- )IIIIX
    12
    14 
    						
    							FV-05VS1
    FV-08VS1
    These Panasonic ceiling mount ventilation fans use a sirocco fan driven by a capacitor motor. The motor
    is designed to have an extended service life with reduced energy consumption. It also incorporates a
    thermal-cutoff for safety. The grille covering the main body is a spring-loaded, quick-release type. A damper
    for preventing counterflow is provided.
    1 81Thumb screwLong screw
    (M4X30)Quantity Appearance
    Part name
    Grille
    Suspension
    bracketI
    Suspension
    bracketII
    1
    1
    Screw
    (M4X8)I2
    1Suspension
    bracketIII
    Screw
    (M4X10)II2
    Spacer1 
    						
    							Unit: ( )inches mm
    (For 16 inches on center joists, only use suspension bracket . For 19.2 inches on center joists, only use
    suspension bracket . If more than 19.2 inches on center joists, use suspension bracket & .)I
    III II III
    FV-05VS1 FV-08VS1
    Junction box cover
    Junction box
    Motor
    Blade
    Part name No. Part nameNo.
    1
    2
    3
    4
    56
    7
    8
    9
    10
    Damper Fan bodyAdaptor
    Grille
    Suspension bracketBracket cover
    1/2 13()
    36/895()
    31/8 78()
    31/8 78()
    11/2 38()
    125()23/860()
    7
    10 1/4 261()
    12 300()
    3 (76)
    13 330()
    10 1/4 261( ) 3 3/4 (94)
    6
    910
    8
    13 330()13 1/4~15 1/2 336~394
    16 1/2~18 3/4 419~480
    21 1/4~23 1/2 540~597()
    ()
    () 
    						
    							Specifications are based on HVI standard.
    Unpack and carefully remove unit from carton.
    Refer to the Supplied Accessories list to verify that all parts are present.
    1. Do not install this ventilating fan where air temperature may exceed 40 C (104 F).oo
    2. Make sure that the electric service supply voltage is 120V, 60 Hz.
    3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation
    Safety and Health Act (OSHA).
    4. Always disconnect the power source before working on or near the fan, motor or junction box.
    5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
    6. Do not kink the power cord.
    7. Do not install the unit where ducts are configured as shown in Fig. A.
    8. Provide suction parts with proper ventilation.
    9. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit.
    Hz
    60
    V Air direction Model No.
    FV-05VS1
    FV-08VS1
    Exhaust120
    (W)
    Power consumptionSpeed
    (rpm)
    4.8 (10.7)
    Weight
    kgIb.( )
    Duct
    diameter
    (inches)Noise
    (sone)
    18 350 7590.8
    26 3
    80 8871.4
    Fig. A
    Prohibition Prohibition Prohibition ProhibitionAdaptor
    4.8 (10.7)
    Air deliver
    (cfm)
    at 0.1 WG. 
    						
    							CAUTION:
    1. For general ventilating use only. Do not use to exhaust
    hazardous or explosive materials and vapors.
    2. Not for use in cooking area. (Fig. B)
    3. This product must be properly grounded.Floor
    Do not install above or(Cooking area)
    inside this area
    45o45o
    equipmentCooking
    Fig. B
    WARNING:
    To reduce the risk of fire, electric shock or injury to persons, observe the following:
    A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact
    to the manufacturer.
    B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all
    applicable codes and standards, including fire-rated construction.
    C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
    of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturers
    guideline and safety standards such as those published by the National Fire Protection Association
    (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers
    (ASHRAE) and the local code authorities.
    D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
    E. Ducted fans must always be vented to the outdoors.
    F. These models are UL listed for tub and shower enclosures.
    G. Solid state controls may cause harmonic distortion which can cause motor humming noise. To reduce
    the risk of fire or electric shock, do not use this unit with any solid-state control device.
    H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting
    means to prevent power from being switched on accidentally. When the service disconnecting means
    cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
    I. NEVER place a switch where it can be reached from a tub or shower.
    J. Not to be installed in a ceiling thermally insulated to a value greater than R40.
    Fan body
    Red
    Capacitor
    White
    Black
    Green
    Earth groundJunction box
    White
    Black
    GreenNeutral
    Live
    EarthPower supply
    AC120V 60Hz
    Green
    K. Install the fan at least 1.5m (5 feet) above the floor, and the fan must be installed above a counter or major
    appliances that serves as a barrier.
    White 
    						
    							6
    2 Screw (M4X8)I
    Suspension bracketIIISuspension bracketII
    2. Insert the supension bracket into the fan body and
    adaptor. (Select the suspension bracket as shown below)
    Spacing A on center joists
    Insert Suspension bracket
    12 inches
    16 inches
    19.2 inches vertical joists
    24 inchesRefer to Fig. 2-1
    Refer to Fig. 2-2
    Refer to Fig. 2-3
    Refer to Fig. 2-4
    If spacing A on center joists is 24 inches, connect
    suspension bracket and (C4 mark to C4 mark)
    as shown below :II III
    Joists
    ASuspension
    bracketI
    Fig.2-1
    Fan body
    Suspension
    bracketISuspension
    bracketIII
    Fig.2-2
    Fan body
    Suspension
    bracketIII
    Suspension
    bracketI
    Fig.2-3
    Fig.2-4Fan body
    Suspension
    bracketI
    Suspension
    bracketIII
    Suspension
    bracketII
    Fig.1
    Fan body
    Remove tape Adaptor
    Damper
    1. Before installation, secure the fan body to adaptor by
    using thumb screw. (Fig.1)
    IMPORTANT :
    Remove the tape from damper and adaptor
    before installation. As shown below:Fan body
    Thumb screw 
    						
    							2 Long screws
    (M4X30)
    screw (M4X10)II
    Fan bodyJoist
    2 Long screws
    (M4X30)
    Joist
    4 Long screws (M4X30)Fan body
    5. Remove junction box cover and secure conduit or
    stress relief to junction box knock-out hole. (Fig. 5)
    6. Refer to wiring diagram (page 5).
    Using wire nuts, connect house power wires to
    ventilating fan wires:
    black to black; white to white; green to green;
    Replace the junction box cover. (Fig. 5)
    CAUTION:Mount junction box cover carefully so that lead
    wires are not pinched. 4. Install the suspension bracket to joists by using long
    screws (M4X30) and secure it to the fan body by
    using screw (M4X10). (Fig. 4)II 3. Install the suspension bracket and the flange of fan
    body to joists by using long screws (M4X30) according
    to Fig. 3.
    7. Install a circular duct and secure it with duct tape
    or clamps.
    Fig. 4
    Fig. 5
    Fig. 3-2 Fig. 3-1
    A = 10 1/4~12 inches
    Junction box coverConduitCircular duct
    Wire nut
    Conduit
    Junction box
    Green wires Lead wires
    Duct tape 
    						
    							CAUTION:Joists Adaptor
    2 Long screws
    (M4X30)
    Fig. 7
    CeilingSlotMounting spring
    Grille
    12 1/8(305)
    inches mm()Fig. 8
    8. Finish ceiling work. Ceiling hole should be aligned
    with the edge of the flange. (Fig. 6)
    9. Insert mounting springs into slots as shown and
    mount grille to fan body. (Fig. 7)
    8
    1. Disconnect plug connector from receptacle and
    remove adaptor from fan body before starting
    installation.
    2. Insert the suspension bracket into the adaptor and
    secure it to joists by using long screws (M4X30). (Fig. 8)
    3. Follow step 5 to 7 of the Installation (page 7) to
    complete the duct work and wiring.I
    If spacing A between joists is 21 1/4 to 23 1/2
    inches, connect suspension bracket and
    (C4 mark to C4 mark) according to page 6.
    Select the suspension bracket according to
    spacing A as shown below.II III
    suspension
    bracketsuspension
    bracketIsuspension
    bracketIIIsuspension
    bracket &II III Spacing A
    between Joists
    inches (mm)13 1/4~15 1/2
    ( 336~394 )16 1/2~18 3/4
    ( 419~480 )21 1/4~23 1/2
    ( 540~597 )
    Fig. 6inches (mm)
    4. Insert to fan body
    (refering to step 2 of Installation , page 6).the suspension bracket in
    I
    2 Long screws
    (M4X30)
    Adaptor
    13 1/4~15 1/2 ( 336~394 )
    16 1/2~18 3/4 ( 419~480 )
    21 1/4~23 1/2 ( 540~597 )Suspension bracket
    no more than 1/2 (13)B
    A
    Ceiling
    12 1/8(305)
    Ensure that distance B is no more than 1/2 inch (13 mm). 
    						
    							9
    Fig. 9
    Fig. 11
    2 Long screws
    (M4X30)screw (M4X10)II
    Conduit
    Junction box cover
    Circular duct
    Joist
    Fan body
    Adaptor
    claws
    9
    Make sure that adaptor claws are properly inserted
    into body slots.
    IMPORTANT:
    5. Insert the fan body into joists. (Fig. 9)
    6. Secure the fan body to adaptor by using thumb
    screw and plug connector to receptacle. (Fig. 10)
    7. Secure to joists by using
    long screws (M4X30) and secure it to fan body by
    using screw (M4X10) in vertical direction. (Fig. 11)the suspension bracket
    II
    8. Follow step 8 to 9 of Installation (page 8) to
    complete the installation work.I
    Fig.12-1
    Adaptor
    4 Screws
    Fig.12-4
    4 Screws
    Screw driver
    Fig.12-3
    Fan body
    Fig.12-2
    Fan body
    Blower
    When mounting
    body and blower
    separately
    1. Loosen 4 screws (but
    do not remove them
    from blower). (Fig. 12-1)
    2. Remove blower section.
    (Fig. 12-2)
    4. Insert fan body (without
    blower section) into
    joists. (Fig. 9)
    5. Secure the adaptor to
    fan body by using thumb
    screw. (Fig. 10)
    7. Insert the blower into the
    fan body. (Fig. 12-3) 3. Remove adaptor from fan
    body and secure it to
    joists as in Fig. 8 of
    page 8.
    6. Secure the fan body
    to joists by using long
    screw(M4X30). (Fig. 11)
    8. Secure the blower.
    (Fig. 12-4) and plug
    connector to receptacle.
    (Fig. 10)
    Fig. 10Thumb
    screwPlug connectorI
    ReceptacleI
    Ceiling
    Joist 
    						
    							10
    C1
    C2
    C3
    C44 kinds of -joist
    inches (mm)I
    9/16 ( )14.3
    11/16 (17.5)
    31/32 (24.6)
    1 17/32 38.9()
    Suspension bracket
    The suspension can comply with
    different kinds of -joist.III
    III
    I bracket
    1. Before installation, Secure the fan body to adaptor by
    using thumb screw. (Fig. 1 of page 6)
    2. Connect the suspension to fan body. (Fig. 13)
    (Select the hole by checking joist size fix the screw
    to the frame hole.)bracketIII
    I-
    3. Connect the ventilating fan to the joist. (Fig. 14)I-
    4. Follow step 5 to 9 of installation (page 7, page 8) to
    complete the installation work.I
    2. Insert the suspension bracket into the bracket cover of
    adaptor side and the back of the fan body. (Fig.15)
    (select the suspension bracket according to spacing A
    as shown below)
    1. Before installation, Secure the fan body to adaptor by
    using thumb screw. (Fig.1 of page 6)
    Fig. 13
    Fig. 14
    C
    C3
    C4
    C1
    C2
    Screw (M4X10)II Suspension
    bracketIII
    4 Long screws
    (M4X30)I-joist
    16 inches and 19.2
    inches horizontal joist
    and
    19.2 inches vertical joist
    A
    Suspension bracketI
    Suspension bracketIIISuspension bracketII
    A = 16 inches and 19.2 inches horizontal joist
    Fig.15-1
    Suspension bracketIII
    A = 19.2 inches vertical joist
    Suspension bracketIISuspension bracketIFig.15-2 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Ventilation Fan Fv 05vs1 Installation Instructions