Ventilating Fan FV-05VS1 FV-08VS1 READ AND SAVE THESE INSTRUCTIONS.R Please readthese instructionscarefullybeforeattempting toinstall, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference. Description Dimensions Specifications Table of Contents Supplied Accessories Unpacking General Safety Information 4 4-54 32 2 5 Wiring Diagram 13 12 8-9 10 10-11 Installation( In Existing Construction )VI Installation( Wooden Header )V 16 16Maintenance Practical Guide to Installation 16Product Service 6-8IInstallation( Joist Mounting- )I Installation( Joist Mounting- )IIII ( -Joist Mounting )I InstallationIII Installation ( Between Joist Mounting )IV 14-15 IInstallation( Wall Installation- )IVI Installation( Wall Installation- )III VII Installation( Wall Installation- )IIIIX 12 14
FV-05VS1 FV-08VS1 These Panasonic ceiling mount ventilation fans use a sirocco fan driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal-cutoff for safety. The grille covering the main body is a spring-loaded, quick-release type. A damper for preventing counterflow is provided. 1 81Thumb screwLong screw (M4X30)Quantity Appearance Part name Grille Suspension bracketI Suspension bracketII 1 1 Screw (M4X8)I2 1Suspension bracketIII Screw (M4X10)II2 Spacer1
Unit: ( )inches mm (For 16 inches on center joists, only use suspension bracket . For 19.2 inches on center joists, only use suspension bracket . If more than 19.2 inches on center joists, use suspension bracket & .)I III II III FV-05VS1 FV-08VS1 Junction box cover Junction box Motor Blade Part name No. Part nameNo. 1 2 3 4 56 7 8 9 10 Damper Fan bodyAdaptor Grille Suspension bracketBracket cover 1/2 13() 36/895() 31/8 78() 31/8 78() 11/2 38() 125()23/860() 7 10 1/4 261() 12 300() 3 (76) 13 330() 10 1/4 261( ) 3 3/4 (94) 6 910 8 13 330()13 1/4~15 1/2 336~394 16 1/2~18 3/4 419~480 21 1/4~23 1/2 540~597() () ()
Specifications are based on HVI standard. Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. 1. Do not install this ventilating fan where air temperature may exceed 40 C (104 F).oo 2. Make sure that the electric service supply voltage is 120V, 60 Hz. 3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). 4. Always disconnect the power source before working on or near the fan, motor or junction box. 5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 6. Do not kink the power cord. 7. Do not install the unit where ducts are configured as shown in Fig. A. 8. Provide suction parts with proper ventilation. 9. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit. Hz 60 V Air direction Model No. FV-05VS1 FV-08VS1 Exhaust120 (W) Power consumptionSpeed (rpm) 4.8 (10.7) Weight kgIb.( ) Duct diameter (inches)Noise (sone) 18 350 7590.8 26 3 80 8871.4 Fig. A Prohibition Prohibition Prohibition ProhibitionAdaptor 4.8 (10.7) Air deliver (cfm) at 0.1 WG.
CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area. (Fig. B) 3. This product must be properly grounded.Floor Do not install above or(Cooking area) inside this area 45o45o equipmentCooking Fig. B WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following: A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact to the manufacturer. B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. E. Ducted fans must always be vented to the outdoors. F. These models are UL listed for tub and shower enclosures. G. Solid state controls may cause harmonic distortion which can cause motor humming noise. To reduce the risk of fire or electric shock, do not use this unit with any solid-state control device. H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. I. NEVER place a switch where it can be reached from a tub or shower. J. Not to be installed in a ceiling thermally insulated to a value greater than R40. Fan body Red Capacitor White Black Green Earth groundJunction box White Black GreenNeutral Live EarthPower supply AC120V 60Hz Green K. Install the fan at least 1.5m (5 feet) above the floor, and the fan must be installed above a counter or major appliances that serves as a barrier. White
6 2 Screw (M4X8)I Suspension bracketIIISuspension bracketII 2. Insert the supension bracket into the fan body and adaptor. (Select the suspension bracket as shown below) Spacing A on center joists Insert Suspension bracket 12 inches 16 inches 19.2 inches vertical joists 24 inchesRefer to Fig. 2-1 Refer to Fig. 2-2 Refer to Fig. 2-3 Refer to Fig. 2-4 If spacing A on center joists is 24 inches, connect suspension bracket and (C4 mark to C4 mark) as shown below :II III Joists ASuspension bracketI Fig.2-1 Fan body Suspension bracketISuspension bracketIII Fig.2-2 Fan body Suspension bracketIII Suspension bracketI Fig.2-3 Fig.2-4Fan body Suspension bracketI Suspension bracketIII Suspension bracketII Fig.1 Fan body Remove tape Adaptor Damper 1. Before installation, secure the fan body to adaptor by using thumb screw. (Fig.1) IMPORTANT : Remove the tape from damper and adaptor before installation. As shown below:Fan body Thumb screw
2 Long screws (M4X30) screw (M4X10)II Fan bodyJoist 2 Long screws (M4X30) Joist 4 Long screws (M4X30)Fan body 5. Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. (Fig. 5) 6. Refer to wiring diagram (page 5). Using wire nuts, connect house power wires to ventilating fan wires: black to black; white to white; green to green; Replace the junction box cover. (Fig. 5) CAUTION:Mount junction box cover carefully so that lead wires are not pinched. 4. Install the suspension bracket to joists by using long screws (M4X30) and secure it to the fan body by using screw (M4X10). (Fig. 4)II 3. Install the suspension bracket and the flange of fan body to joists by using long screws (M4X30) according to Fig. 3. 7. Install a circular duct and secure it with duct tape or clamps. Fig. 4 Fig. 5 Fig. 3-2 Fig. 3-1 A = 10 1/4~12 inches Junction box coverConduitCircular duct Wire nut Conduit Junction box Green wires Lead wires Duct tape
CAUTION:Joists Adaptor 2 Long screws (M4X30) Fig. 7 CeilingSlotMounting spring Grille 12 1/8(305) inches mm()Fig. 8 8. Finish ceiling work. Ceiling hole should be aligned with the edge of the flange. (Fig. 6) 9. Insert mounting springs into slots as shown and mount grille to fan body. (Fig. 7) 8 1. Disconnect plug connector from receptacle and remove adaptor from fan body before starting installation. 2. Insert the suspension bracket into the adaptor and secure it to joists by using long screws (M4X30). (Fig. 8) 3. Follow step 5 to 7 of the Installation (page 7) to complete the duct work and wiring.I If spacing A between joists is 21 1/4 to 23 1/2 inches, connect suspension bracket and (C4 mark to C4 mark) according to page 6. Select the suspension bracket according to spacing A as shown below.II III suspension bracketsuspension bracketIsuspension bracketIIIsuspension bracket &II III Spacing A between Joists inches (mm)13 1/4~15 1/2 ( 336~394 )16 1/2~18 3/4 ( 419~480 )21 1/4~23 1/2 ( 540~597 ) Fig. 6inches (mm) 4. Insert to fan body (refering to step 2 of Installation , page 6).the suspension bracket in I 2 Long screws (M4X30) Adaptor 13 1/4~15 1/2 ( 336~394 ) 16 1/2~18 3/4 ( 419~480 ) 21 1/4~23 1/2 ( 540~597 )Suspension bracket no more than 1/2 (13)B A Ceiling 12 1/8(305) Ensure that distance B is no more than 1/2 inch (13 mm).
9 Fig. 9 Fig. 11 2 Long screws (M4X30)screw (M4X10)II Conduit Junction box cover Circular duct Joist Fan body Adaptor claws 9 Make sure that adaptor claws are properly inserted into body slots. IMPORTANT: 5. Insert the fan body into joists. (Fig. 9) 6. Secure the fan body to adaptor by using thumb screw and plug connector to receptacle. (Fig. 10) 7. Secure to joists by using long screws (M4X30) and secure it to fan body by using screw (M4X10) in vertical direction. (Fig. 11)the suspension bracket II 8. Follow step 8 to 9 of Installation (page 8) to complete the installation work.I Fig.12-1 Adaptor 4 Screws Fig.12-4 4 Screws Screw driver Fig.12-3 Fan body Fig.12-2 Fan body Blower When mounting body and blower separately 1. Loosen 4 screws (but do not remove them from blower). (Fig. 12-1) 2. Remove blower section. (Fig. 12-2) 4. Insert fan body (without blower section) into joists. (Fig. 9) 5. Secure the adaptor to fan body by using thumb screw. (Fig. 10) 7. Insert the blower into the fan body. (Fig. 12-3) 3. Remove adaptor from fan body and secure it to joists as in Fig. 8 of page 8. 6. Secure the fan body to joists by using long screw(M4X30). (Fig. 11) 8. Secure the blower. (Fig. 12-4) and plug connector to receptacle. (Fig. 10) Fig. 10Thumb screwPlug connectorI ReceptacleI Ceiling Joist
10 C1 C2 C3 C44 kinds of -joist inches (mm)I 9/16 ( )14.3 11/16 (17.5) 31/32 (24.6) 1 17/32 38.9() Suspension bracket The suspension can comply with different kinds of -joist.III III I bracket 1. Before installation, Secure the fan body to adaptor by using thumb screw. (Fig. 1 of page 6) 2. Connect the suspension to fan body. (Fig. 13) (Select the hole by checking joist size fix the screw to the frame hole.)bracketIII I- 3. Connect the ventilating fan to the joist. (Fig. 14)I- 4. Follow step 5 to 9 of installation (page 7, page 8) to complete the installation work.I 2. Insert the suspension bracket into the bracket cover of adaptor side and the back of the fan body. (Fig.15) (select the suspension bracket according to spacing A as shown below) 1. Before installation, Secure the fan body to adaptor by using thumb screw. (Fig.1 of page 6) Fig. 13 Fig. 14 C C3 C4 C1 C2 Screw (M4X10)II Suspension bracketIII 4 Long screws (M4X30)I-joist 16 inches and 19.2 inches horizontal joist and 19.2 inches vertical joist A Suspension bracketI Suspension bracketIIISuspension bracketII A = 16 inches and 19.2 inches horizontal joist Fig.15-1 Suspension bracketIII A = 19.2 inches vertical joist Suspension bracketIISuspension bracketIFig.15-2