Have a look at the manual Panasonic Ventilating Fan Fv 08vkml1, Fv 08vksl1 Installating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
READ AND SAVE THESE INSTRUCTIONS.R Please readthese instructionscarefullybeforeattempting toinstall, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference. 15-16 16 8-107 Table of Contents Unpacking General Safety Information 14VInstallation( Wooden Header ) 12 14 Installation( In Existing Construction )VI IInstallation( Joist Mounting- )I III( -Joist Mounting )I Installation Maintenance Practical Guide to Installation 16Product Service 2Please Read Prior To Installing This Fan 13Installation ( Between Joist Mounting )IV 11-12II( Joist Mounting- )II Installation Model No.FV-08VKML1 FV-08VKSL1 Ventilating Fan FV-08VKML1 FV-08VKSL1 Thank you very much for having purchased our Ventilating Fan. Description Dimensions Specifications64 3 3 Supplied Accessories Wiring Diagram Switch Indication Operation 5 5 6 3
than the minimum ENERGY STAR requirements. 5 efficient FV-08VKSL1 FV-08VKML1 only). ventilating
These Panasonic ventilating fans use a sirocco fan with dolphin-shaped blades driven by brushless direct current motor powered by an integral transformer. The motor is designed to have long operating life, high dynamic response, higher speed ranges with saving energy. The grille can be quickly detached from the main unit. A damper for preventing air counterflow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. SUPPLIED ACCESSORIES UNPACKING DESCRIPTION The lighting unit is an energy-saving, lighting device which uses two 18W fluorescent lamps and produces almost the same illumination as a standard 100W incandescent lamp. This Panasonic ventilating fan (FV-08VKML1) is equipped with a motion sensor that runs automatically when motion is detected. It is user-adjustable to operate 0.5~60 minutes after motion is no longer detected. Quantity Appearance Part name Screw (ST4.2X8)I21 Grille Suspension bracketI Suspension bracketII 1 1 2Screw (ST4.2X12)II Screw (ST4.2X16)III 1 Machine screw (M4X8)2 Quantity Appearance Part name 2 1 1 18W Fluorescent lamp 4W Night lamp Lighting unit 1Suspension bracketIII 6Long screw (ST4.2X20) FV-08VKML1 FV-08VKSL1 1 Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present.
DIMENSIONS Unit: ( )inches mm (For 16 inches on center joists, only use suspension bracket , for 19.2 inches on center joists, only use suspension bracket , If more than 19.2 inches on center, use suspension bracket & .)I III II III Junction box cover Junction box Lighting unit Fluorescent lamp Night lamp Part name No.Part name No. 1 2 3 4 5 67 8 9 10 11 Damper Fan bodyAdaptor Grille Suspension bracket Bracket cover 12Sensor unit FV-08VKSL1 FV-08VKML1 6 13 330() 10 1/4 261() 3 1/2 (90) 8 9 10 37/8 98()10 1/4 (261) 12 1/8 (307) 6 13 330() 10 1/4 261() 3 1/2 (90) 8 9 10 37/8 98()10 1/4 (261) 12 1/8 (307) 12 11 113 1/2 (90)1 (25) 5 1/8 130() 7 7/8 200() 126() 23/470() 3 1/4 (81) 13 1/4~15 1/2 ( 336~394 ) 16 1/2~18 3/4 ( 419~480 ) 21 1/4~23 1/2 ( 540~597 ) 7 3 1/2 (90)1 (25) 5 1/8 130() 7 7/8 200() 126() 23/470() 3 1/4 (81) 13 1/4~15 1/2 ( 336~394 ) 16 1/2~18 3/4 ( 419~480 ) 21 1/4~23 1/2 ( 540~597 ) 7 4 3/5 (116) 4 3/5 (116)
SWITCH INDICATION 30 40 50 60 70 80 Delay Time [min] WI ING DIAG AMRRWI ING DIAG AMRR Low speed air-volume preset switch positions Air Volume [cfm] High/Low delay time preset switch positions 0.5 1235 10 2030 60 Factory setting : 20 minutes Position 0 : Use for factory test only. 0 Factory setting : 50 cfm Switch indications on blower unit Low speed air vol- ume preset switch High / Low delay time preset switch FV-08VKML1 FV-08VKSL1 White White Position use for factory test only. CFM
Duct diameter (inches) 416.5 7.5() (cfm)(rpm) FV-08VKML1 FV-08VKSL1 9.5 7.7 6.5 5.8 5.0 70 60 50 40 30 700 666 647 628 620
CAUTION: 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. Not for use in cooking area. (Fig. B) 3. This product must be properly grounded. 45o45o Floor Do not install above or(Cooking area) inside this area equipmentCooking Fig. B 3. Follow all local electrical and safety codes, as well as the National Electrical Codethe Occupation Safety and Health Act (OSHA). (NEC) and 4. Always disconnect the power source before working on or near the fan, motor or light fixture. 5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 6. Do not kink the power cord. 7. Do not install the unit where ducts are configured as shown in Fig. A. 8. Provide suction parts with proper ventilation. GENE AL SAFETY INFO MATIONRRGENE AL SAFETY INFO MATIONRR 1. Do not install this ventilating fan where air temperature may exceed 40 C (104 F).oo 2. Make certain that the electric service supply voltage is AC 120V, 60 Hz. Fig. AAdaptor Prohibited 9. This unit is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit. 10. This product has a fluorescent lamp that contains mercury. Disposal may be regulated in your community due to environmental considerations. For disposal or recycling information, please contact your local authorities or the Electronics Industries Alliance: http://www.eiae.org Prohibited Prohibited Prohibited WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following; A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact to the manufacturer. B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. E. Ducted fans must always be vented to the outdoors. F. Do not use this unit with any solid-state control device. Solid state controls may cause harmonic distortion which can cause motor humming noise. G. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. H. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for installation in Canada only.)
8 2-Screw (ST4.2X8)I Suspension bracketIIISuspension bracketII INSTALLATION JOIST MOUNTING-II()INSTALLATION JOIST MOUNTING-II() 1. Insert the suspension bracket into the fan body and adaptor. (select the suspension bracket as shown below) Spacing A on center joists Insert Suspension bracket 12 inches 16 inches 19.2 inches vertical joists 24 inchesRefer to Fig. 1-1 Refer to Fig. 1-2 Refer to Fig. 1-3 Refer to Fig. 1-4 If spacing A on center joists is 24 inches, connect suspension bracket and (C4 mark to C4 mark) as shown below :II III Joists A Suspension bracketIII Suspension bracketI Fig.1-1 Fig.1-2 Fig.1-3 Fig.1-4 Fan body Fan body Suspension bracketI Suspension bracketIII Suspension bracketII Suspension bracketI Fan body Suspension bracketISuspension bracketIII Fan body Tape Damper Adaptor IMPORTANT :Remove the tape from damper and adaptor before installation. As shown below:
Fan body 4 Long screws (ST4.2X20) Joist 9 Fig.2-2 INSTALLATION JOIST MOUNTING-II( ) CONTINUEDINSTALLATION JOIST MOUNTING-II( ) CONTINUED 3. Install the suspension bracket to joists by using long screws (ST4.2X20) and secure it to the fan body by using screw (ST4.2X12) (Fig.3)II Junction box cover Fig.4 ConduitCircular duct 4. Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. (Fig.4) CAUTION:Mount junction box cover carefully so that lead wires are not pinched. 6. Install a circular duct and secure it with duct tape or clamps. Fig.2-1 2. Install the suspension bracket and the flange of fan body to joists by using long screws (ST4.2X20) ( If spacing A between joists is 12 inches, install the flange of fan body according to Fig.2-1, others according to Fig.2-2 to install the product) Duct tape Fig.3 2 Long screws (ST4.2X20) Screw (ST4.2X12)II Joist Joist 5. Refer to wiring diagram of page 5. Follow all the local electrical safety codes. As well as the National Electrical Code (NEC). Using UL approved wire nuts, connect house power wires to ventilating fan wires: black to black; white to white; green to green; Connect the two red wires to the switch for the speed control. Replace the junction box cover. (Fig.4) Joist Wire nutGreen wires Lead wiresRed wires ConduitJunction box 2 Long screws (ST4.2X20)Fan body Junction box Wire nut Lead wires Conduit Green wires
10 7/8(275) 10 7/8(275) Ceiling Sensor unitGrille Ceiling Fig.6-2 Gloves INSTALLATION JOIST MOUNTING-II( ) CONTINUEDINSTALLATION JOIST MOUNTING-II( ) CONTINUED 8. Insert the plug connector into the receptacle , and secure the lighting unit to the fan body with 1 screw (ST4.2X16) and 2 machine screws (M4X8). (Fig.5)II II III 9. Insert the fluorescent lamps and s cure the night lamp into the lighting unit. (Fig.5)e 12. Insert mounting springs into the slots as shown and mount grille to fan body. (FV-08VKSL1) (Fig.7)Lighting unit 7. Finish ceiling work. Ceiling hole should be aligned with the edge of the flange. (Fig.5) 10 Slot Grille Mounting spring Lighting unit Ceiling Fig.7 10. Insert mounting spring into the slot as shown and adjust high /low delay time preset switch and low speed air volume preset switch. Refer to switch indication of page 5 (FV-08VKML1) (Fig.6-1) 11. Insert the sensor unit into the housing of the grille and insert other mounting spring into the slot as shown and mount grille to fan body (FV-08VKML1) (Fig.6-2, Fig.6-3) Grille Mounting springCeiling Fig.6-3 Gloves Gloves Fig.5 Screw (ST4.2X16)III Machine screw (M4X8) 4 W Night lamp Fluorescent lamps inches (mm) Fig.6-1 Sensor unit Ceiling GrilleLighting unit Plug connectorII Machine screw (M4X8) CAUTION: Mount grille carefully so that lead wires are not pinched.