Home
>
Panasonic
>
Telephone
>
Panasonic Va-824 Key Telephone System Installation And Programming Manual
Panasonic Va-824 Key Telephone System Installation And Programming Manual
Have a look at the manual Panasonic Va-824 Key Telephone System Installation And Programming Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
METHOD OF PROGRAMMING _.. Read the following paragraphs before proceeding to the actual programming instructions and procedures. These notes and procedures are intended to acclimate the programmer to the proper programmingsequencerequired prior to the actual programming. . Programming of initial set a Assure that the RAM switch is posi- tioned at “CLR” side. 0 Set the power switch to the “ON” position. @ After about 5 seconds, assure that the DATA MONIT lamps is flashing. @ Change the RAM switch from the “CLR” side to “HOLD” side. The initial set programming is now com- pleted through the above operations. NOTE If you change the programming again, the RAM switch is not necessary switched over. 5
. Method of programming All programming changes are made at Extension No. 10 and it isrecommend- ccl to use key telephone with a LCD display (VA-l 2022 or VA-12022-B). 0 Press the ON/OFF button. The ON/ OFF indicator and MIC indicator lights up and a continuous tone is emitted. @ Press the ~]~~~l~~~](The continuous tone will stop) and then press the dial keyr/(iq (X: mode numbers 1 to 7) mode 1: System setting mode 2: COL setting mode 3: Key telephone setting mode 4: Incoming call ringing setting mode 5: Line/FF key setting mode 6: Restriction setting mode 7: Display time setting 8 Press the program step numbers for the desired feature option. Refer to the PROGRAMMING TABLE for programmable feature option. @ Press the q key to store the memo- ry. The next program step will appear on the LCD display. When mode numbers of the programming features to be changed are the same, program step numbers of the programmings to be changed can be input after the registration. Therefore, the programm- ing changes can be performed continu- ously for the programming features having the same mode number. @ Press the ON/OFF button and display will return to the clock mode (ON/ OFF indicator and MIC indicator will go off). . Mode confirmation If you want to confirm the mode num- ber during programming, you can do so with the LCD disolav bv inouttina MIC indicator LCD display ON/OFF Button 6
rogramming flowchart - - r 1 * 000 I ,l I (Set up for program mode) (Mode set) 7
r ,’ Names and phone numbers list 00 118 136 54 72 I 55 173 I 01 19 37 56 174 I 02 20 38 03 21 39 I 58 176 04 22 40 05 23 41 60 178 06 24 42 I 61 179 07 25 43 I 62 180 08 26 44 63 (81 09 27 45 I 64 I82 10 28 -----------I- ----------------------- -~~ 11 29 47 67 85 I 13 31 49 14 32 50 15 33 51 16 34 52 17 35 53 68 86 69 87 I 70 88 71 89 8
PROGRAMMING TABLE -. The set contents of all programming features should be recorded and stored according to the following table. System setting Outside access number from PBX Amount of time ause time store speed dial group A speed dial group B 0 1 2 3 4 5 6 7 8 9 No alarm tone Have alarm tone Long speech alarm *1os-0 *108-l 9
FEATURE I OPTION SELECTED I Automatic answering for incoming calls No auto answering Only handset auto answering Handset 8 ON/OFF key +109-o *109-1 +109-z Ringing telephone for night time incom- ing calls Only night time ring set TEL will ring I COL ring set TEL will ring,too I +110-o +110-o I Hold recall No recall *111-o In the immediate After 30 set After 1 min Connection of door box Can not connect Can be connect Type of applicable sensors 113-o Detect - close +113-1 Detect - open 1 Sensor alarm stopping method 114-o By sensor By handset (Off - hooking) 1114-l SLT on-hooking jetection *115-o 0.05 to 0.5sec +115-1 0.05 to 1.2sec No connection Connection 116-O -116-l No recall In the immediate After 30 set After 1 min After 2 min +117-o x117-1 X117-2 x117-3 +i17-4 Connection of DSS Hold recall for DSS TEL SMDR output No data out put Printer mode SMDR mode *201-o *201-1 1201-2 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS X203-1 x203-2 x203-3 *203-4 x203-5 *203-6 SMDR baud rate setting 7 SMDR data configuration 7bit/l bit 7bitll bit 7bit/2bit 7bit/2bit Ebit/l bit 8bit/l bit 8bit/2bit 8bit/2bit Even No. Cdd No. Even No. Odd No. Even No. Odd No. Even No. Odd No. *204-1 x204-2 x204-3 x204-4 X204-5 *204-C x204-7 *204-6 *0101-o Non 1 + area code *0101-1 1 + area code Restriction when necessary to dial “1” for first digit Restriction on out- side calls using l or # keys *0102-o Restricted *0102-1 Not restricted 6 Not 8 digits 9 digits 10 digits 11 digits 12 digits 13 digits 14 digits 15 digits 16 digits 0103-O 1 *0103-1 10103-2 *0103-3 X0103-4 0103-5 *0103-6 X0103-7 I*o103-8 l*o103-9 Restriction by num- ber of digits when making outside calls I I I I I I I I Outside dialing restricted Same content as that programmed outside dialing restrrction 0104-O x0104-1 Restriction on out- side calls using out- side lines on which incomin calls receive 8 10
r 6 FEATURE OPTION SELECTED I Restriction release by specified dial code (1 + area) Restric$on release by specified dial code (1 + area) x 0113 Restriction release by specified dial code (1 + area) +0114- Restriction release by specified dial code (1 + area) 1 0 11 1 2) 3 14 [ 576 17 18 19 1 Clear I I I I I I I I I I I I I I I I I I I I 11
6 FEATURE I OPTION SELECTED I +3striction release my specified dial mode (1 + area) 0 1 2 3 4 5 6 7 8 9 ?estriction release ,y specified dial Clear H mode (1 + area) I OI’I Restriction release 3y specified dial 0 1 2 3 4 5 6 7 8 9 mode (1 + area) Restriction release I I I I I I I I by specified dial 0 1121314~5161718l9 code (1 + area) 12
COL setting 2 :oL 2 Tel. No. : FEATURE OPTION SELECTED I I Dialing system for Tone Pulse t sutside calls *0201-o *0201-i Kind of outside line COL connected to the PBX system -0202-O *0202-1 (COL or PBX) Specification for automatic connect- Not designated Designated ing to outside lines *0203-O *0203-l Tone dialing signal 80 m set 240 m set duration *0204-O *0204-l Minimum pause for 80 m set 160 msec tone dialing signal i 0205-O *0205-1 2 Tel. No. : OPTION SELECTED Dialing system for Tone dial Pulse dial outside calls *0101-o *0101-1 Kind of outside line COL connected to the PBX system ~0102-0 *0102-1 (COL or PBX) Specification for automatic connect- Not designated Designated ing to outside lines *0103-o *0103-1 Tone dialing signal 80 m set 240 m set duration +0104-o x0104-1 Minimum pause for 80 m set 160 msec tone dialing signal i 0105-O *0105-1 6 set Detection time of a set ncoming ring signal r0107-0 6 0107-l Detection time of Incoming ring signal +o2o7-o 6 set *0207-l 8 set 13