Panasonic Th 42ps10rs Operating Instructions
Have a look at the manual Panasonic Th 42ps10rs Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
1/3Options Off-timer function INPUT lock Studio W/B Advanced PIP Display size Initial VOL level Maximum VOL level Initial INPUT Onscreen display Off Off Off Off Enable On Off 0 Off Off 0 41 Options Adjustments 1 2 3 5Press to display the Setup menu. Press to select “OSD Language”. Press and hold until the Options menu is displayed. Press to select your preferred menu. Press to adjust the menu. Press to exit from Options menu. 4 6 Item Effect Adjustments Off-timer function EnableDisable Enable: Enables the “Off-timer function”. Disable: Disables the “Off-timer function”. Note: When “Disable” is set, the Off-timer is cancelled. Onscreen display On Off On: Displays all the following on screen. • Power on display • Input signal switch display • No signal display • Mute and the remaining time of off-timer after was pressed. Off: Hides all the items above from view. Initial INPUTOff PC INPUT1 INPUT2 INPUT3 Adjusts the input signal when the unit is turned on. Notes: • Only the adjusted signal is displayed. (see page 13). • Signal can be displayed when the Terminal board is installed. • This menu is available only when “INPUT lock” is “Off”. • When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B) (For TH-42PS10RK/S) Ofrecido por www.electromanuales.com
1/3Options Off-timer function INPUT lock Studio W/B Advanced PIP Display size Initial VOL level Maximum VOL level Initial INPUT Onscreen display Off Off Off Off Enable On Off 0 Off Off 0 42 Options Adjustments Item Effect Adjustments Initial VOL level Off On Press button to adjust the volume when the unit is turned on. Off On Off: Sets normal volume. On: Sets your preferred volume. Notes: • When “Maximum VOL level” is “On”, the volume can only be adjusted between 0 and your maximum range.• You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Initial VOL level” is “On” and cursor is on the menu. Maximum VOL level Off On Press button to adjust the maximum volume. Off On Off: Sets auto maximum volume. On: Sets your preferred maximum volume. Notes: • If the “Maximum VOL level” is set lower than the “Initial VOL level”, the “Initial VOL level” automatically becomes the same as the “Maximum VOL level”. • The volume display can go up to 63 regardless of the settings. • You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Maximum VOL level” is “On” and cursor is on the menu. INPUT lockOff PC INPUT1 INPUT2 INPUT3 Locks the input switch operation. Notes: • Only the adjusted signal is displayed (see page 13). • Signal can be displayed when the Terminal board is installed. • Input switch can be used when this is set to “Off”. • In two screen display mode, if anything other than “Off” is set, the value will be fi xed as the value input in the single screen display mode. • When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B) Studio W/B Off On Off: Nullify all the settings adjusted. On: Sets the colour temperature for TV studio. Note: Valid only when the low is set as colour temperature on screen adjustment. Advanced PIP Off On Off: Sets normal two screen display mode (see page 20). On: Sets Advanced PIP mode (see page 21). Notes: • When “INPUT lock” is “On”, you cannot use all the two screen display functions. • , buttons are unavailable during Advanced PIP mode operation. Display size Off On Adjusts the image display size on screen. Off: Sets the normal image display size on screen. On: Sets the image display size approximately 95 % of the normal image display. Off On Notes: • This setting is valid only when the input signals are as follows; 525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p, 1125/30p, 1250/50i (Component Video, RGB, DVI, SDI, HDMI) • This setting is invalid when two screen display, digital zoom or Multi screen is selected. • When “Display size” is set to “On”, Pos. /Size adjustment cannot be used. • Refer to each board’s operating instruction for DVI, SDI, HDMI’s corresponding signals. Ofrecido por www.electromanuales.com
2/3Options OffOffOff Off 0 Remote ID Serial ID ID select Button lock Remocon User level 3/3Options Off Off Off V. lnstallation Rotate Slot1 Serial Slot Select Slot power Normalization When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID” adjustments, set all the values “Off” so that all the buttons are enabled again. Press the button on main unit together with button on the remote control and hold for more than 5 seconds. The “SHIPPING” menu is displayed and the lock is released when it disappears.Item Effect Adjustments Button lockOff MENU&ENTER On Off: All the buttons at the bottom of the main unit can be used. MENU & ENTER: Locks MENU and ENTER/ buttons on bottom face of main unit. On: Locks all the button on bottom face of main unit. Remocon User levelOff User1 User2 User3 Off: You can use all of the buttons on the remote control. User1: You can only use , , , , , , , buttons on the remote control. User2: You can only use , , buttons on the remote control. User3: Locks all the buttons on remote control. ID selectSets panel ID number when panel is used in “Remote ID” or “Serial ID”. Set value range: 0 - 100 (Standard value: 0) Remote ID Off On Off: Disables ID remote control functions. You can use normal remote control operations. On: Enable ID remote control functions. Serial ID Off On Sets the panel ID Control. Off: Disables external control by the ID. On: Enables the external control by the ID. Item Effect Adjustments Slot PowerOff Auto On Off: Power is not transmitted to the slot power. Auto: Power is transmitted to the slot power only when main power is on. On: Power is transmitted to the slot power when main power is on or in the standby state. Note: In some cases, power is transmitted to the slot power when main power is on or in the standby state regardless of the slot power setting. V.Installation Off On Off: Sets fan to the horizontal installation mode. On: Sets fan to the vertical installation mode. Notes: • This functions when display is turned on. • Vertical installation is available without this mode setting. • Turn up the power switch for the upward direction when you set Display vertically. Rotate Off On Off: Does not rotate the image. On: Rotates the image 180 degrees. Serial Slot SelectSlot1 Slot2 Slot3 Selects the slot which communicates serial. Note: The setting of an external command can be set only from the fi xed serial terminal (see page 10). 43 Options Adjustments Ofrecido por www.electromanuales.com
Options Weekly Command Timer Initial VOL level 1/3 Off Off 0 0 Maximum VOL level Off INPUT lock Off Button lock Off Remocon User level Off Advanced PIP Initial INPUT Onscreen display On O f f 44 Item Effect Adjustments Weekly Command TimerSets Weekly Command Timer. (see page 48) Onscreen display On Off On: Displays all the following on screen. • Power on display • Input signal switch display • No signal display • Mute and the remaining time of off-timer after was pressed. Off: Hides all the items above from view. Initial INPUTOff PC INPUT1 INPUT2 INPUT3 Adjusts the input signal when the unit is turned on. Notes: • Only the adjusted signal is displayed. (see page 13). • Signal can be displayed when the Terminal board is installed. • This menu is available only when “INPUT lock” is “Off”. • When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B) 1 2 3 5Press to display the Setup menu. Press to select “OSD Language”. Press and hold until the Options menu is displayed. Press to select your preferred menu. Press to adjust the menu. Press to exit from Options menu. 4 6 (For TH-42PH10RK/S, TH-50PH10RK/S, TH-58PH10RK) Options Adjustments Ofrecido por www.electromanuales.com
Options On Weekly Command Timer Onscreen display Off Initial INPUT 1/3 Maximum VOL level Initial VOL level Button lock INPUT lock Advanced PIP Remocon User level Off Off 0 0 Off Off Off Off 45 Item Effect Adjustments Initial VOL level Off On Press button to adjust the volume when the unit is turned on. Off On Off: Sets normal volume. On: Sets your preferred volume. Notes: • When “Maximum VOL level” is “On”, the volume can only be adjusted between 0 and your maximum range.• You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Initial VOL level” is “On” and cursor is on the menu. Maximum VOL level Off On Press button to adjust the maximum volume. Off On Off: Sets auto maximum volume. On: Sets your preferred maximum volume. Notes: • If the “Maximum VOL level” is set lower than the “Initial VOL level”, the “Initial VOL level” automatically becomes the same as the “Maximum VOL level”. • The volume display can go up to 63 regardless of the settings. • You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Maximum VOL level” is “On” and cursor is on the menu. INPUT lockOff PC INPUT1 INPUT2 INPUT3 Locks the input switch operation. Notes: • Only the adjusted signal is displayed (see page 13). • Signal can be displayed when the Terminal board is installed. • Input switch can be used when this is set to “Off”. • In two screen display mode, if anything other than “Off” is set, the value will be fi xed as the value input in the single screen display mode. • When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B) Button lockOff MENU&ENTER On Off: All the buttons at the bottom of the main unit can be used. MENU & ENTER: Locks MENU and ENTER/ buttons on bottom face of main unit. On: Locks all the button on bottom face of main unit. Sets Button lock with the unit buttons in the following procedure. Off: Press four times→Press INPUT four times→Press four times→Press ENTER/MENU & ENTER: Press ENTER/ four times→Press four times→Press INPUT four times→Press ENTER/On: Press four times→Press ENTER/ four times→Press four times→Press ENTER/ Remocon User levelOff User1 User2 User3 Off: You can use all of the buttons on the remote control. User1: You can only use , , , , , , , buttons on the remote control. User2: You can only use , , buttons on the remote control. User3: Locks all the buttons on remote control. Advanced PIP Off On Off: Sets normal two screen display mode (see page 20). On: Sets Advanced PIP mode (see page 21). Notes: • When “INPUT lock” is “On”, you cannot use all the two screen display functions. • , buttons are unavailable during Advanced PIP mode operation. Options Adjustments Ofrecido por www.electromanuales.com
Options EnableOff-timer function NormalInitial Power Mode0ID selectOffRemote IDOffSerial IDOffDisplay sizeOffStudio W/BOffStudio Gain 2/3 46 Item Effect Adjustments Off-timer function EnableDisable Enable: Enables the “Off-timer function”. Disable: Disables the “Off-timer function”. Note: When “Disable” is set, the Off-timer is cancelled. Initial Power ModeNormal Standby On Sets the power mode of the unit for when the power recovers from failure or after plugging off and in again. Normal: Power returns in as the same state as before the power interruption. Standby: Power returns in standby mode. (Power Indicator : red/orange) On: Power returns in power On. (Power Indicator : green) Note: When using multiple displays, “Standby” is preferred to be set in order to reduce a power load. ID selectSets panel ID number when panel is used in “Remote ID” or “Serial ID”. Set value range: 0 - 100 (Standard value: 0) Remote ID Off On Off: Disables ID remote control functions. You can use normal remote control operations. On: Enable ID remote control functions. Serial ID Off On Sets the panel ID Control. Off: Disables external control by the ID. On: Enables the external control by the ID. Display size Off On Adjusts the image display size on screen. Off: Sets the normal image display size on screen. On: Sets the image display size approximately 95 % of the normal image display. Off On Notes: • This setting is valid only when the input signals are as follows; NTSC, PAL, SECAM, M.NTSC, PAL60, PAL-M, PAL-N (BNC Dual Video Terminal Board (TY-FB9BD)) 525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i, 1125/24sF, 1125/25p, 1125/24p, 1125/30p, 1250/50i (Component Video, RGB, DVI, SDI, HDMI) • This setting is invalid when two screen display, digital zoom or Multi screen is selected. • When “Display size” is set to “On”, Pos. /Size adjustment cannot be used. • Refer to each board’s operating instruction for DVI, SDI, HDMI’s corresponding signals. Studio W/B Off On Off: Nullify all the settings adjusted. On: Sets the colour temperature for TV studio. Note: Valid only when the low is set as colour temperature on screen adjustment. Studio Gain Off On Sharpens the contrast for a better view when a part of the image is too light to see. Off: Disables “Studio Gain”. On: Enables “Studio Gain”. Note: This setting is valid only when the input signals are as follows: Component Video, RGB (analog), SDI, HDMI Options Adjustments Ofrecido por www.electromanuales.com
3/3Options Off Off Off V. lnstallation Rotate Slot1 Serial Slot Select Slot power Normalization When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID” adjustments, set all the values “Off” so that all the buttons are enabled again. Press the button on main unit together with button on the remote control and hold for more than 5 seconds. The “SHIPPING” menu is displayed and the lock is released when it disappears. 47 Item Effect Adjustments Slot PowerOff Auto On Off: Power is not transmitted to the slot power. Auto: Power is transmitted to the slot power only when main power is on. On: Power is transmitted to the slot power when main power is on or in the standby state. Note: In some cases, power is transmitted to the slot power when main power is on or in the standby state regardless of the slot power setting. V.Installation Off On Off: Sets fan to the horizontal installation mode. On: Sets fan to the vertical installation mode. Notes: • This functions when display is turned on. • Turn up the power switch for the upward direction when you set Display vertically. Rotate Off On Off: Does not rotate the image. On: Rotates the image 180 degrees. Serial Slot SelectSlot1 Slot2 Slot3 Selects the slot which communicates serial. Note: The setting of an external command can be set only from the fi xed serial terminal (see page 10). Options Adjustments Ofrecido por www.electromanuales.com
Options On Weekly Command TimerOnscreen display 1/3 Weekly Command Timer On Program1Function Monday Program3Tuesday --- Wednesday Program3Thursday --- Friday Program6Saturday Program4Sunday Program Edit Weekly Command Timer Program1On Monday Function Program3Tuesday --- Wednesday Program3Thursday --- Friday Program6Saturday Program4Sunday Program Edit Program3Thursday --- Friday Program6Saturday Program4Sunday Program Edit Weekly Command Timer 8:00 10:30 01 02 1/8 --:-- 03--:-- 04--:-- --:-- 0512:00 069:12 PON IMS:SL1 --- --- --- --- DAM:ZOOM AVL:10 0708 1Program Program number 48 You can set 7-day timer programming by setting time and command. Note: Before setting Weekly Command Timer, set PRESENT TIME Setup. (see page 27) Press to select Function. Press to select “On”. Note: • When Function is set to On, Set up TIMER (see page 28) is unavailable and Interval / Time Designation in Mode of Screensaver (see page 29) cannot be selected. 1 Press to select a day. Press to select a program number. Note: • You can set the program from 1 to 7. --- indicates unset. 2 Press to select Program Edit. Press to show the Program Edit screen. Press to select Program. Press to change the program numbers (1-7). 4 3 Press ACTION ( ) button Program Edit screen Options Adjustments Weekly Command Timer (for TH-42PH10RK/S, TH-50PH10RK/S, TH-58PH10RK) Ofrecido por www.electromanuales.com
Weekly Command Timer 20:00 20:30 57 58 8/8 22:00 59 --:-- 60 --:-- --:-- 61 --:-- 62 --:-- AVL:00 DAM:NORM POF --- --- --- --- --- 63 64 1Program Weekly Command Timer 8:00 10:30 02 01 1/8 --:-- 03--:-- 04--:-- --:-- 0512:00 069:12 PON IMS:SL1 --- --- --- --- DAM:ZOOM AVL:10 0708 1Program Weekly Command Timer 0210:30 Command No Time IMS:SL1 Command 1Program Weekly Command Timer Command 02Command No IMS:SL1 10:30 Time 1Program 49 Press to select a command number. Press to show the previous / next command pages (1-8) of the selected program. Press to show the command setting screen. 5 Press to select Command No. Press to select a command number. 6 Press to select Time / Command. Press to set each item. Time: Set the time to execute a command program. Pressing “ ” or “ ” button once changes “Time” 1 minute. Pressing “ ” or “ ” button continuously changes “Time” by 15 minutes. Command:Select a command to execute at the set time. This unit has 64 commands to set. (see page 53) Notes: • Command is performed in order of execution time, regardless of the command number. • If a command execution time overlaps with that of other commands, these commands are performed in number order. • Pressing , Time becomes --:-- and Command becomes ---. 7 Note: • Press to return to the previous screen.Command setting screen Command (--- indicates unset) Set time of timer(--:-- indicates unset) Command numbers Options Adjustments Ofrecido por www.electromanuales.com
1/2 Signal PC Off Standby save Off Power management Off Auto power off Off OSD Language English ( UK) Component/RGB-in select RGB Input label Power save Setup SHIPPINGYES 50 Shipping condition This function allows you to reset the unit to the factory setting. 1 2 3 4 Press to display the Setup menu. Press to select “OSD Language”. Press and hold till the SHIPPING menu is displayed. Press to select “YES”. Press to confi rm. [from the unit] 1 Press the MENU button till the Setup menu is displayed. 2 Press the Volume Up“+” or Down“–” button to select “OSD Language”. 3 Press and hold the ENTER button till the SHIPPING menu is displayed. 4 Press the Volume Up“+” or Down“–” button to select “YES”. 5 Press the ENTER button and wait for 10 sec. Note: Press the R button to return to Setup menu when SHIPPING menu is displayed. Ofrecido por www.electromanuales.com