    Have a look at the manual Panasonic System Controller Wv Cu650 Wv Cu950 Calibration Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							2-1
    CALIBRATION PROCEDURE
    1. Pan / Tilt Calibration
    3The Pan / Tilt Calibration is required in the fol-
    lowing cases.
    •After replacing the EEPROM, Pan / Tilt and Zoom wheel
    Calibration is required.
    (Default software data will be stored in the EEPROM
    automatically.)
    •In the case of changing of the combination of the Main
    Unit and the 3D Joystick Unit as shown in the Exploded
    View(10/10).
    •In the case of replacing of the Joystick Board (PCB 5) or
    VR101 and other parts on it.
    •In case of replacing the Main Board (PCB 1) or EEPROM
    (IC6 ) and other parts on it.
    •In case that calibrated data has been changed by opera-
    tion mistake.
    3Procedure
    1.  Turn off the power.
    2.  To execute the Pan / Tilt Calibration Mode, Turn on the
    power while pressing the [9] and [MON(ESC)] keys
    simultaneously.
    The LCD on the Front Panel will indicate as right.
    3.  Enter the administrator password.
    Notes: • The factory default is "650".
    • To delete a character, press the CLEAR button.
    Note: Just example, It depends on Unit
    4.  Press the [CAM(SET)] key.
    The LCD on the Front Panel will indicate as right.
    5.  Press the [CAM(SET)] key for the starting adjustment.
    The LCD on the Front Panel will indicate as right.
    6.  Turn and keep the Joystick to fully upper side.
    The LCD on the Front Panel will indicate as right.7.  Press the [CAM(SET)] key while turning the Joystick to
    upper side.
    The LCD on the Front Panel will indicate as right.
    8.  Turn and keep the Joystick to fully down side.
    The LCD on the Front Panel will indicate as right.
    9.  Press the [CAM(SET)] key while turning the Joystick to
    down side.
    The LCD on the Front Panel will indicate as right.
    10. Return the Joystick to center.
    The LCD on the Front Panel will indicate as right.
    Note : It needs your hand to release with flipping.
    11.  Press the [CAM(SET)] key.
    The LCD on the Front Panel will indicate as right.
    12.  Turn and keep the Joystick to fully right side.
    The LCD on the Front Panel will indicate as right.
    13.  Press the [CAM(SET)] key while turning the Joystick to
    right side.
    The LCD on the Front Panel will indicate as right.
    Pan/Tilt Calibration 
    Admin Password _____
    U:F2 D:09 TC:78    0 
    R:E6 L:06 PC:75    0
    U:__ D:__ TC:__   72 
    R:__ L:__ PC:__    
    U:__ D:__ TC:__   F0 
    R:__ L:__ PC:__    
    U:F1 D:__ TC:__   7D 
    R:__ L:__ PC:__    
    U:F1 D:__ TC:__   08 
    R:__ L:__ PC:__    
    U:F1 D:08 TC:__   08 
    R:__ L:__ PC:__    
    U:F1 D:08 TC:__   70 
    R:__ L:__ PC:__    
    U:F1 D:08 TC:70   79
    R:__ L:__ PC:__    
    U:F1 D:08 TC:70    
    R:__ L:__ PC:__   F1
    U:F1 D:08 TC:70    
    R:F0 L:__ PC:__   F0
    Blinking 
    						
    							2-2 14.  Turn and keep the Joystick to fully left side.
    The LCD on the Front Panel will indicate as right.
    15.  Press the [CAM(SET)] key while turning the Joystick to
    left side.
    The LCD on the Front Panel will indicate as right.
    16. Return the Joystick to center.
    The LCD on the Front Panel will indicate as right.
    Note : It needs your hand to release with flipping.
    17.  Press the [CAM(SET)] key.
    The LCD on the Front Panel will indicate as right,
    18.  Confirm the following.
    •  The LCD on the Front Panel will indicate 64 steps of
    each change, when it turns to the upper and lower sides
    and right.
    • The value of Pan and Tilt on the LCD will return to
    ZERO, when the Joystick is returned to the center.
    19.  Turn off the power to finish the calibration.
    2. Zoom Wheel Calibration
    3The Zoom Wheel Calibration is required in the
    following cases
    • In case of replacing the Joystick Unit.
    • In case of disassembling the Joystick Unit.
    • In case of replacing the Main Board.
    • In case of replacing the EEPROM (IC6 on the Main
    Board).
    • In case that calibrated data has been changed by oper-
    ation mistake.
    3Procedure
    1.  Turn off the power.
    2.  To execute the Pan / Tilt Calibration Mode, Turn on the
    power while pressing the [8] and [MON(ESC)] keys
    simultaneously.
    The LCD on the Front Panel will indicate as right.
    3. Enter the administrator password.
    Notes: • The factory default is "650".
    • To delete a character, press the CLEAR button.
    Note: Just example, It depends on Unit.
    4. Press the [CAM(SET)] key.
    The LCD on the Front Panel will indicate as right.
    5. Press the [CAM(SET)] key for the starting adjustment.
    The LCD on the Front Panel will indicate as right.
    6.  Turn and keep the Zoom Wheel to fully right (TELE)
    side.
    The LCD on the Front Panel will indicate as right.
    U:F1 D:08 TC:70    
    R:F0 L:__ PC:__   07
    U:F1 D:08 TC:70    
    R:F0 L:07 PC:__   07
    U:F1 D:08 TC:70    
    R:F0 L:07 PC:__   76
    U:F1 D:08 TC:70    0
    R:F0 L:07 PC:76    0
    U:F1 D:08 TC:70    0
    R:F0 L:07 PC:76    0
    Zoom Calibration 
    Admin Password _____
    T:BC W:45 ZC:7D    0
    T:__ W:__ ZC:__   84 
    T:__ W:__ ZC:__   BD  
    						
    							2-3 7. Press the [CAM(SET)] key while turning the Zoom
    Wheel to right (TELE) side.
    The LCD on the Front Panel will indicate as right.
    8. Turn and keep the Zoom Wheel to fully left (WIDE) side.
    The LCD on the Front Panel will indicate as right.
    9. Press the [CAM(SET)] key while turning the Zoom
    Wheel to left (WIDE) side.
    The LCD on the Front Panel will indicate as right.
    10.  Return the Zoom Wheel to center.
    The LCD on the Front Panel will indicate as right.
    Note : When the Zoom Wheel is in fully left side,
    release the hand as quickly as possible.
    11. Press the [CAM(SET)] key.
    The LCD on the Front Panel will indicate as right.
    12.  Confirm the following.
    • The LCD on the Front Panel will indicate 4 steps of
    each change, when the Zoom Wheel turns to the WIDE
    and TELE sides.
    • The value of WIDE and TELE on the LCD will return to
    ZERO, when the Zoom Wheel is returned to the center..
    13.  Turn off the power to finish the calibration.
    T:BD W:__ ZC:__   BD 
    T:BD W:__ ZC:__   45 
    T:BD W:45 ZC:__   45 
    T:BD W:45 ZC:__   81 
    T:BD W:45 ZC:81    0