    Have a look at the manual Panasonic Single Monitor Station Vl Gm201a Installation And Operation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							11
    Introduction and Installation
    Wiring schematic diagram
    Note:
    LThis door opener wiring schematic diagram is only an example. Refer to the wiring 
    instructions provided with your door opener and PBX for details.
    LRefer to the technical data on page 30 when connecting to a door opener.
    Power cable/wire type and distance
    LPower cable (between the monitor station and the AC adaptor):
    Ty p e :  Ф1.2 Fire alarm cable 16 AWG 
    Distance: Maximum 30 m (about 98 feet)
    LWire (between the monitor station and the door station):
    Type: General cable CAT-3 24 AWG
    Distance: Maximum 100 m (about 328 feet)
    Loop resistance: 18.4 Ω or lower
    LWire (between the monitor station and PBX):
    Type: General cable CAT-3 24 AWG
    Distance: Maximum 100 m (about 328 feet)
    D1
    D2
    Door station
    Monitor station
    AC adaptor Power cable
    (Non polar)
    (Non polar)
    (Non polar)
    D1
    D2
    P1
    P2
    S1
    S2
    PBX
    (Example: KX-TDA50)
    Door opener
    Terminal box
    (4-conductor wiring)
    Power cord
    GM201A.book  Page 11  Monday, April 4, 2005  5:10 PM 
    						
    							12
    Introduction and Installation
    Installing the monitor station
    Note:
    LWhen connecting to a PBX, make sure the {PBX MODE} switch is set to {ON} before 
    installing the monitor station (page 20).
    1Install the mounting bracket to a wall using the wood screws (4 mm x 16 mm, 3/16 x 5/8).
    LRemove the mounting bracket from the rear of the monitor station beforehand.
    LBefore drilling, see page 10 for installation location.
    2Attach the power cable to the terminal. See page 18 for details on how to attach the power 
    cable.
    LIf you want to use your own power cable, see page 11 for the type and distance.
    Wall
    Mounting bracket
    83.5 mm
    (3
    5/16)
    Wood screws
    Terminal (Non polar)
    Power cable
    GM201A.book  Page 12  Monday, April 4, 2005  5:10 PM 
    						
    							13
    Introduction and Installation
    3Attach the wires that connect to the door station to the terminal. See page 18 for details 
    on how to attach the wires.
    LSee page 11 for the wire type and distance.
    LSee the wiring schematic diagram on page 11.
    LIf you want to connect the wires and the power cable without them going through a hole 
    in the wall behind the mounting bracket, connect by passing the wires through the wire 
    guide, and the power cable through the power cable guide.
    ButtonTerminal
    (Non polar)
    Wire (Not included)
    Stripped end of the wire
    9 mm
    (3/8)
    Power cable guide
    Wire guide
    GM201A.book  Page 13  Monday, April 4, 2005  5:10 PM 
    						
    							14
    Introduction and Installation
    4Mount the monitor station to the mounting bracket.
    Push the monitor station down until it is secure.
    5Take out the AC adaptor and the DC terminal from the case.
    LPush the arrow mark on the front case, then release from the rear case.
    LTake out the cardboard and wood screws. The wood screws are necessary when 
    attaching the AC adaptor and the DC terminal to a wall (page 16).
    1
    2
    AC adaptor
    DC terminal
    Arrow mark
    GM201A.book  Page 14  Monday, April 4, 2005  5:10 PM 
    						
    							15
    Introduction and Installation
    6Connect the power cable to the DC terminal, the power cord to the AC adaptor, then 
    connect the power cord to the AC outlet (100 V 
    – 240 V, 50 Hz / 60 Hz).
    LBe sure to connect the power cable to the 2 holes on the left side of the DC terminal.
    LFor details on how to attach the power cable, see page 18.
    7Attach the DC cord to the clamp on the rear of the DC terminal.
    LThis will help to avoid the DC cord to disconnect from the DC terminal.
    To AC outlet
    DC terminal
    Power cableAC adaptorPower cord
    12 3
    DC cord
    DC terminal
    Clamp
    GM201A.book  Page 15  Monday, April 4, 2005  5:10 PM 
    						
    							16
    Introduction and Installation
    To attach the AC adaptor and the DC terminal to a wall
    By placing the AC adaptor and the DC terminal in the case and mounting the case to the wall, 
    you can protect the AC adaptor and the DC terminal from tampering and exposure.
    Note:
    LDisconnect the DC cord from the clamp on the rear of the DC terminal beforehand. See 
    step 7 on page 15 for details.
    LTake out the cardboard and wood screws from the AC case beforehand.
    1Attach the rear part of the case to a wall using the wood screws (4 mm x 16 mm, 3/16 x 5/8).
    2Pack the AC adaptor and DC terminal as shown.
    1.Pack the AC adaptor in the rear case.
    LBe sure to run the power cord through the power cord hole.
    2.Pack the DC cord in the rear case.
    LBe sure to bundle the DC cord so that it will not touch the bottom of the case.
    3.Pack the DC terminal in the rear case.
    LBe sure to run the wires through the wire hole, then under the wire rib.
    Wall Case
    83.5 mm
    (3
    5/16)
    Wood screws
    Wire ribWire hole
    Power cord holePower cord
    3 DC terminal
    2 DC cord1 AC adaptor
    GM201A.book  Page 16  Monday, April 4, 2005  5:10 PM 
    						
    							17
    Introduction and Installation
    3Attach the front of the case.
    Note:
    LTo open the case again, push the bottom of the front case, then release from the rear case.
    1
    2
    GM201A.book  Page 17  Monday, April 4, 2005  5:10 PM 
    						
    							18
    Introduction and Installation
    To attach the power cable
    LWhile pressing on the button with a pointed object such as a screwdriver, insert the power 
    cable into the terminal connector.
    LTo disconnect the power cable, press on the button while pulling out.
    LTo attach an optional power cable, cut off about 12 mm (
    1/2) of the cable cover (1), then 
    push in firmly until the end of the cable is securely inserted into the power connection 
    terminal (2).
    To attach the wires
    LStrip off of the wire cover so that about 9 mm (
    3/8) of the wire is exposed.
    LWhile pressing on the button with a pointed object such as a screwdriver, insert the wire into 
    the terminal connector.
    LTo disconnect a wire, press on the button while pulling out.Monitor station DC terminal
    12 Power cable cross section
    Button
    Terminal connectorButton
    Terminal 
    connector
    12 mm 
    (1/2)
    Correct Incorrect
    Button
    Terminal connector
    GM201A.book  Page 18  Monday, April 4, 2005  5:10 PM 
    						
    							19
    Introduction and Installation
    Using the desktop stand (Optional)
    You can place the monitor station on a desktop. See page 7 for optional item information.
    Note:
    LIf you previously connected the power cable through the power cable guide (page 13), 
    remove the power cable from the power cable guide of the monitor station beforehand, then 
    attach to the desktop stand.
    Desktop stand
    Power cableMounting bracket
    Wire
    Wood screws
    GM201A.book  Page 19  Monday, April 4, 2005  5:10 PM 
    						
    							20
    Using the Unit
    Tu r n i n g  {PBX MODE} switch ON/OFF
    When connecting to a PBX (page 22), turn {PBX MODE} switch on. If not, turn {PBX MODE} 
    switch off. The default setting is {ON}.
    1Remove the switch cover from the rear of the monitor station.
    LUse a sharp, thin object such as a mechanical pencil.
    2Select {ON} (default) or {OFF}.
    Switch cover
    OFFPBX MODEON