Have a look at the manual Panasonic Single Monitor Station Vl Gm201a Installation And Operation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 Introduction and Installation Wiring schematic diagram Note: LThis door opener wiring schematic diagram is only an example. Refer to the wiring instructions provided with your door opener and PBX for details. LRefer to the technical data on page 30 when connecting to a door opener. Power cable/wire type and distance LPower cable (between the monitor station and the AC adaptor): Ty p e : Ф1.2 Fire alarm cable 16 AWG Distance: Maximum 30 m (about 98 feet) LWire (between the monitor station and the door station): Type: General cable CAT-3 24 AWG Distance: Maximum 100 m (about 328 feet) Loop resistance: 18.4 Ω or lower LWire (between the monitor station and PBX): Type: General cable CAT-3 24 AWG Distance: Maximum 100 m (about 328 feet) D1 D2 Door station Monitor station AC adaptor Power cable (Non polar) (Non polar) (Non polar) D1 D2 P1 P2 S1 S2 PBX (Example: KX-TDA50) Door opener Terminal box (4-conductor wiring) Power cord GM201A.book Page 11 Monday, April 4, 2005 5:10 PM
12 Introduction and Installation Installing the monitor station Note: LWhen connecting to a PBX, make sure the {PBX MODE} switch is set to {ON} before installing the monitor station (page 20). 1Install the mounting bracket to a wall using the wood screws (4 mm x 16 mm, 3/16 x 5/8). LRemove the mounting bracket from the rear of the monitor station beforehand. LBefore drilling, see page 10 for installation location. 2Attach the power cable to the terminal. See page 18 for details on how to attach the power cable. LIf you want to use your own power cable, see page 11 for the type and distance. Wall Mounting bracket 83.5 mm (3 5/16) Wood screws Terminal (Non polar) Power cable GM201A.book Page 12 Monday, April 4, 2005 5:10 PM
13 Introduction and Installation 3Attach the wires that connect to the door station to the terminal. See page 18 for details on how to attach the wires. LSee page 11 for the wire type and distance. LSee the wiring schematic diagram on page 11. LIf you want to connect the wires and the power cable without them going through a hole in the wall behind the mounting bracket, connect by passing the wires through the wire guide, and the power cable through the power cable guide. ButtonTerminal (Non polar) Wire (Not included) Stripped end of the wire 9 mm (3/8) Power cable guide Wire guide GM201A.book Page 13 Monday, April 4, 2005 5:10 PM
14 Introduction and Installation 4Mount the monitor station to the mounting bracket. Push the monitor station down until it is secure. 5Take out the AC adaptor and the DC terminal from the case. LPush the arrow mark on the front case, then release from the rear case. LTake out the cardboard and wood screws. The wood screws are necessary when attaching the AC adaptor and the DC terminal to a wall (page 16). 1 2 AC adaptor DC terminal Arrow mark GM201A.book Page 14 Monday, April 4, 2005 5:10 PM
15 Introduction and Installation 6Connect the power cable to the DC terminal, the power cord to the AC adaptor, then connect the power cord to the AC outlet (100 V – 240 V, 50 Hz / 60 Hz). LBe sure to connect the power cable to the 2 holes on the left side of the DC terminal. LFor details on how to attach the power cable, see page 18. 7Attach the DC cord to the clamp on the rear of the DC terminal. LThis will help to avoid the DC cord to disconnect from the DC terminal. To AC outlet DC terminal Power cableAC adaptorPower cord 12 3 DC cord DC terminal Clamp GM201A.book Page 15 Monday, April 4, 2005 5:10 PM
16 Introduction and Installation To attach the AC adaptor and the DC terminal to a wall By placing the AC adaptor and the DC terminal in the case and mounting the case to the wall, you can protect the AC adaptor and the DC terminal from tampering and exposure. Note: LDisconnect the DC cord from the clamp on the rear of the DC terminal beforehand. See step 7 on page 15 for details. LTake out the cardboard and wood screws from the AC case beforehand. 1Attach the rear part of the case to a wall using the wood screws (4 mm x 16 mm, 3/16 x 5/8). 2Pack the AC adaptor and DC terminal as shown. 1.Pack the AC adaptor in the rear case. LBe sure to run the power cord through the power cord hole. 2.Pack the DC cord in the rear case. LBe sure to bundle the DC cord so that it will not touch the bottom of the case. 3.Pack the DC terminal in the rear case. LBe sure to run the wires through the wire hole, then under the wire rib. Wall Case 83.5 mm (3 5/16) Wood screws Wire ribWire hole Power cord holePower cord 3 DC terminal 2 DC cord1 AC adaptor GM201A.book Page 16 Monday, April 4, 2005 5:10 PM
17 Introduction and Installation 3Attach the front of the case. Note: LTo open the case again, push the bottom of the front case, then release from the rear case. 1 2 GM201A.book Page 17 Monday, April 4, 2005 5:10 PM
18 Introduction and Installation To attach the power cable LWhile pressing on the button with a pointed object such as a screwdriver, insert the power cable into the terminal connector. LTo disconnect the power cable, press on the button while pulling out. LTo attach an optional power cable, cut off about 12 mm ( 1/2) of the cable cover (1), then push in firmly until the end of the cable is securely inserted into the power connection terminal (2). To attach the wires LStrip off of the wire cover so that about 9 mm ( 3/8) of the wire is exposed. LWhile pressing on the button with a pointed object such as a screwdriver, insert the wire into the terminal connector. LTo disconnect a wire, press on the button while pulling out.Monitor station DC terminal 12 Power cable cross section Button Terminal connectorButton Terminal connector 12 mm (1/2) Correct Incorrect Button Terminal connector GM201A.book Page 18 Monday, April 4, 2005 5:10 PM
19 Introduction and Installation Using the desktop stand (Optional) You can place the monitor station on a desktop. See page 7 for optional item information. Note: LIf you previously connected the power cable through the power cable guide (page 13), remove the power cable from the power cable guide of the monitor station beforehand, then attach to the desktop stand. Desktop stand Power cableMounting bracket Wire Wood screws GM201A.book Page 19 Monday, April 4, 2005 5:10 PM
20 Using the Unit Tu r n i n g {PBX MODE} switch ON/OFF When connecting to a PBX (page 22), turn {PBX MODE} switch on. If not, turn {PBX MODE} switch off. The default setting is {ON}. 1Remove the switch cover from the rear of the monitor station. LUse a sharp, thin object such as a mechanical pencil. 2Select {ON} (default) or {OFF}. Switch cover OFFPBX MODEON {PBX MODE} switch GM201A.book Page 20 Monday, April 4, 2005 5:10 PM