Page 111
ENGLISH – 111 Information Monitor Lamp Indicators Five monitor lamps are provided at the top of main unit front to inform the user of the lamp replacement time and unusual internal temperature. These lamps indicate the degree of abnormality by combination of blinking and/or lighting lamps. Turn off the power and take the proper measure according to the table below. FILTER CLEANINGOPEN CLOSE LAMP 4 monitor (LAMP 4) LAMP 2 monitor (LAMP 2) LAMP 1 monitor (LAMP 1) LAMP 3 monitor (LAMP 3) Temperature...
Page 112
112 – ENGLISH Cleaning and replacement of air filter If the air filter is blocked with too much dust, the inside of the projector will become hot and the temperature monitor (TEMP) indicator will flash and the power will turn off. The static electric mesh filter should be replaced and the metal mesh filter and brush inside the filter unit should be cleaned after approximately 2 000 hours of use, although this is a guide only and the actual time will vary depending on the operating conditions....
Page 113
ENGLISH – 113 Information Install the movable metal mesh 7. filter to the filter cleaning unit. When reassembling, align the edge of the • movable metal mesh filter with position A. Hook the movable metal mesh filter onto the • gear and the rail. The movable metal mesh filter will be set to the • correct position after the set is installed and the power is turned on, so it can be installed in the middle position during reassembly without any problem. Movable metal mesh filter Rail Install the...
Page 114
114 – ENGLISH Replacement of lamp unit WARNING Wait until the lamp is cooled sufficiently before replacing the lamp unit. • Make sure that all four lamp units are installed. • Replacement of the lamp unit should be carried out by a qualified technician. • Do not remove any screws (such as the black screws) other than those indicated when replacing the • lamp unit. If this is not observed, electric shocks, burns or other injuries may occur. Precautions on lamp unit replacement Be careful when...
Page 115
ENGLISH – 115 Information Procedure of lamp unit replacement Turn the main power OFF, following the procedures described in 1. “Powering up the projector” (p. 38) and “Powering off the projector” (p. 39), disconnect the power plug from the AC power source, and wait for one hour or more. Then check that the lamp unit has cooled down. Use a Phillips screwdriver to 2. loosen the lamp unit cover screw at the rear of the projector until the screw turns freely. Open the lamp unit cover and 3. remove...
Page 116
116 – ENGLISH Notes when installing the ceiling mount bracket When installing the ceiling mount bracket to the projector, install the accessory eye bolts and wires to the projector. (The projector will still be safe if they are not used, however they will help prevent the possibility of accidents caused by the projector falling down if the screws happen to become loose.) Installation should be carried out by a qualified technician by following the procedure given below. Panasonic takes no...
Page 117
ENGLISH – 117 Information Before asking for service œ try to check the following points again. Symptoms Check point Page Power does not turn onIs the power cord securely plugged in the receptacle? • 37 Is the MAIN POWER switch put to the “O” position? • 38-39 Is power supply live at the receptacle? • 37 Is the temperature monitor (TEMP) lamp on the projector front lighting • or blinking?111 Is the lamp monitor (LAMP) lamp on the projector front lighting or • blinking?111 Is the lamp unit cover...
Page 118
118 – ENGLISH Self-diagnosis display There is a self-diagnosis display located on the side of the projector (p. 15) for automatically displaying the corresponding details when an error or warning occurs. Self-diagnosis displayDetails Remedy U04 Air filter is blocked Clean the air filter unit.• U11 Intake air temperature warning Ambient temperature is too high. • U12 Optical module temperature warning U13 Lamp ambient temperature warning U14 Low temperature warning Ambient temperature is too low.•...
Page 119
ENGLISH – 119 Information Self-diagnosis displayDetails Remedy F41 Lamp 1 memory error Problem with lamp. Consult your dealer. • F42 Lamp 2 memory error F43 Lamp 3 memory error F44 Lamp 4 memory error F61 Ballast 1 communication error If turning the main power off and back on again does • not clear the error display, consult your dealer. F62 Ballast 2 communication error F63 Ballast 3 communication error F64 Ballast 4 communication error F80 Resize IC setting error F81 FM-R test error F82 FM-G test...
Page 120
120 – ENGLISH Specifications Model No. PT-D12000U PT-DZ12000U Power supply120 - 240 V, 50 Hz/60 Hz Power consumption1 600,µ1 500, (about 10 W (120V AC) / 15 W (240V AC) in standby) Amps16 Aµ9.0 A DLP ® ChipPanel size0.95 inch (aspect ratio 4:3) 0.96 inch (aspect ratio 16:10) Display systemThree-unit DLP® chip, DLP® type Number of pixels3 × 1 470 000 pixels (1 400 × 1 050 dots) 3 × 2 304 000 pixels (1 920 × 1 200 dots) Lens (Powered zoom/ Powered focus control)Option Projection lamp4 bulbs × 300 W...