Home > Panasonic > Solar Panels > Panasonic Photovoltaic Module HIT 240w Installation Manual

Panasonic Photovoltaic Module HIT 240w Installation Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Photovoltaic Module HIT 240w Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 
     
    11 
     
     
    Figure 3.6 
    Grounding method  
    Using  Grounding  Clip  with  self-
    tapping machine screw 
     
    Note:  Use  the smaller ground 
    holes illustrated in Figure 3.1. 
    Grounding  Clip  Assemblies:  Tyco 
    Electronics 1954381-1. 
     
    Figure 3.7 
    Grounding method  
    Using  Grounding  Clip  with  bolt 
    and nut  
     
    Note: Use the larger ground holes 
    illustrated in Figure 3.1. 
    Grounding  Clip  Assemblies:  Tyco 
    Electronics 1954381-2 
    Glass 
    Backsheet 
    Frame (Longer side) 
    Grounding hole 
    (0.205” diameter (5.2mm)) 
    Grounding Clip 
    8-32 Screw (Stainless steel) 
    Nut (Stainless steel) 
    Copper wire 
    Length  
    (not less than 0.63’‘(16 mm)  
     not more than 0.78’‘(20 mm))  
    Copper wire 
    Frame (Longer side) Glas2 
    Backshee3 
    Grounding hole 
    (0.165” diameter (4.2mm)) 
    Grounding Clip 
    Self-tapping  machine  screw  (Stainless 
    steel) 
    Length  
    (not less than 0.47’‘(12 mm)  
    not more than 0.78’‘(20 mm))     
    						
    							 
     
     
    12 
     
    SPECIFICATIONS    
     
     
    Figure 2   Dimensions 
    Dimensions 
    All HIT Power S Models (VBHNxxxSA11VBHNxxxSA11) 
    Note : A module should be installed on a mounting structure rail in accordance with the following 
    >Use four (4) symmetrical mounting within setting range A. 
    : range A 
    Front Side Backside 
    Dimensions in mm Mount Locations 
    Ground (4 places) 
    Label 
    Onamba 
    Junction Box 
    Negative 
     (-) 
    Positive  
    (+) ModelHIT Power 240SHIT Power 235SHIT Power 230S
    VBHN240SA11VBHN235SA11VBHN230SA11
    VBHN240SA11BVBHN235SA11BVBHN230SA11B
    Cell Number in Series727272
    Rated Power, W atts (Pmax)240235230
    Maximum Power Voltage (Vpm)43.743.042.3
    Maximum Power Current (Ipm)5.515.485.45
    Open Circuit Voltage (Voc)52.451.851.2
    Short Circuit Current (Isc)5.855.845.83
    Cell TypeHeterojunctionHeterojunctionHeterojunction
    Maximum System Voltage (Voc)600600600
    Factory Installed Bypass Diodes  333
    Maximum series fuse (A)151515
    Mechanical Specifications
    Length, mm (inches)
    W idth, mm (inches)
    Frame Depth, mm (inches)
    W eight, kg (pounds)
    35 (1.4)
    15 (33.1)
    Electrical Specifications
    1580 (62.2)
    798 (31.4)     
    						
    All Panasonic manuals Comments (0)