Have a look at the manual Panasonic Network Camera Wv Sfv611l Wv Sfv631l Installation Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
● The MONITOR OUT terminal output can be switched for NTSC or PAL monitors. Installation Guide\ Network Camera Model No. WV-SFV631L/WV-SFV611L WV-SFV631L (This illustration\p represents \fV-S\bV631L) PGQX1455YA Cs1213-1123 Printed in China ● This manual describes the installation procedures, network camera installation, cable connec - tions, and the angle of view adjustment. ● Before reading this manual, be sure to read the Important Information. ● This manual describes how to install the network camera using the WV -SFV631L model as an example. Major operating controls The component names of the camera are as follows. Refer to the illustration when installing or adjusting the camera. Standard accessoriesMaking connections Important Information ...............................1 pc. Installation Guide (this document) ............ 1 set Warranty card ........................................... 1 setCD-ROM*1 ................................................. 1 pc. Code label *2 .............................................. 1 pc. *1 The CD-ROM contains the operating instructions and different kinds of tool software pro - grams. *2 This label may be required for network management. The network administrator shall retain the code label. The following parts are used during installation procedures. A Base bracket ........................................ 1 pc. C Fixing screws for attachment plate (M4 x 8 mm) ...................................... 5 pcs. (of them, 1 for spare) G Template B (for the base bracket) .. 1 sheet. I 2P power cable .................................... 1 pc. K Waterproof tape ................................... 1 pc. B Attachment plate .................................. 1 pc. D 4P alarm cable ..................................... 1 pc. E MONITOR OUT conversion plug ......... 1 pc. F Template A (for the attachment plate) 1 sheet. H Bit ........................................................ 1 pc. J LAN cable cover .................................. 1 pc. H K ● How to initialize the camera Follow the steps below to initialize the network camera. 1 Turn off the power of the camera. When using a PoE hub, disconnect the LAN cable from the cam- era. When using an external power supply, disconnect the 2P power cable plug from the camera. 2 Turn on the power of the camera while holding down the INITIAL SET button, and then keep holding down the button for 5 seconds or more. About 2 minutes later, The camera will start up and the settings including the network settings will be initialized. ● When data is being sent via the network camera Blinks green (accessing)Turn off each system’s power supply before making a connection. Before making connections, prepare the required peripheral devices and cables. ● When the camera is able to communicate with the connected device Lights orange ● When an SD memory card* 1 is inserted and could Lights off → Blinks green → be recognized Lights off ● When data can be saved after the SD memory card is Lights off → Lights green inserted and the SD ON/OFF button is pressed ● When data can be saved to the SD memory card Lights green ● When the SD memory card is removed after holding down Lights green → Blinks green → Lights off the SD ON/OFF button for about 2 seconds ● When data cannot be saved to the SD memory card because Lights off an abnormality was detected or the SD memory card is configured not to be used ● When AF (Auto Focus) operation is being executed Blinks red (Interval of 1 time/ second) ● When the set is being started Lights red ● When an SD memory card is recognized normally Lights red → Lights off ● When an abnormality is detected in both SD1 and SD2 Lights red cards after the camera has started ● When an abnormality is only detected in the SD1 card Lights red → Blinks red after the camera has started (Interval of 1 time/ 3 seconds) ● When an abnormality is only detected in the SD2 card Lights red → Blinks red after the camera has started (Interval of 2 times/ 3 seconds) IMPORTANT: ● When the camera is initialized, the settings including the network settings will be initial - ized. Note that the CRT key (SSL encryption key) used for the HTTPS protocol will not be initialized. ● Before initializing the settings, it is recommended to write down the settings in advance. ● Do not turn off the power of the camera during the process of initialization. Otherwise, it may fail to initialize and may cause malfunction. IMPORTANT: ● This is valid if the [Monitor out] is set to [Switch priority] ([Switch priority] is selected by default). For details, refer to the Operating Instructions (included in the CD-ROM). IMPORTANT: ● Use all 4 pairs (8 pins) of the LAN cable (category 5 or better, straight, STP: For Europe). ● The maximum cable length is 100 m {328 feet}. ● Make sure that the PoE device in use is compliant with IEEE802.3af standard. ● When connecting both the 12 V DC power supply and the PoE device for power supply, 12 V DC will be used for power supply*. * If a 12 V DC power supply and a PoE hub or router are used at the same time, network connections may not be possible. In this case, disable the PoE settings. Refer to the operating instructions of the PoE hub or router in use. ● When the LAN cable is disconnected once, reconnect the cable after around 2 seconds. When the cable is quickly reconnected, the power may not be supplied from the PoE device. ● When cables are used outdoors, there is a chance that they may be af fected by lightning. In this case, install a lightning arrester just before where the cables con - nect to the camera. Connect a LAN cable (category 5 or better, straight, STP: For Europe) Waterproof treatment for the cable joint sections When connecting to a network using a PoE hub Microphone/line input cable Connect a monaural mini plug (ø3.5 mm). ● Input impedance: Approx. 2 kΩ (unbalanced) ● Recommended cable length: Less than 1 m {3.28 feet} (for microphone input) Less than 10 m {32.8 feet} (for line input) ● Recommended microphone: Plug-in power type (option) ● Supply voltage: 2.5 V ±0.5 V ● Recommended sensitivity of microphone: –48 dB ±3 dB (0 dB=1 V/Pa,1 kHz) ● Input level for the line input: Approx. –10 dBV IMPORTANT: ● Be sure to use the 4P alarm cable provided with this product. ● Off, input, and output of the external I/O terminal 2 and 3 can be switched by configur - ing the setting. Refer to the Operating Instructions on the provided CD-ROM for fur - ther information about the EXT I/O terminal 2 and 3 (ALARM IN2, 3) settings (“Off”, “Alarm input”, “Alarm output” or “AUX output”). ● When using the EXT I/O terminals as the output terminals, ensure they do not cause signal collision with external signals. ● Install external devices so that they do not exceed the ratings above. Connect the alarm input/output cable • ALARM IN1(DAY/NIGHT IN), ALARM IN2, ALARM IN3Input specification: No-voltage make contact input (4 V - 5 V DC, internally pulled up) OFF: Open or 4 V - 5 V DC ON: Make contact with GND (required drive current: 1 mA or more) • ALARM OUT, AUX OUT Output specification: Open collector output (maximum applied voltage: 20 V DC) Open: 4 V - 5 V DC by internal pull-up Close: Output voltage 1 V DC or less (maximum drive current: 50 mA) * The default of EXT I/O terminals is “Off”. Connect an external amplifier-embedded speaker to the audio output cable Connect a stereo mini plug (ø3.5 mm) (Audio output is monaural.).* ● Output impedance: Approx. 600 Ω (unbalanced) ● Recommended cable length: Less than 10 m {32.8 feet} ● Output level: –20 dBV IMPORTANT: ● Connect/disconnect the audio cables and turn on the power of the camera after turn - ing off the power of the audio output devices. Otherwise, loud noise may be heard from the speaker. ● Make sure that the stereo mini plug is connected to this cable. When a monaural mini plug is connected, audio may not be heard. When connecting a monaural speaker with amplifier, use a locally procured conver- sion cable (mono-stereo). Adequate waterproof treatment is required for the cables when installing the camera with cables exposed or installing it under the eaves. The camera body is waterproof, but the cable ends are not waterproof. Be sure to use the supplied waterproof tape at the points where the cables are connected to ap - ply waterproof treatment in the following procedure. Failure to observe this or use of a tape other than the provided waterproof tape (such as a vinyl tape) may cause water leakage resulting in malfunction. Before starting the installation, check the entire system configuration. The following illustration gives a wiring example of how to connect the camera to the network via a PoE device (hub). < Alarm input/output cable, power cable, micro - phone/line input cable, audio output cable> Wind the tape in a half-overlapping m\.anner. Wind the tape in a half-overlapping manner . Wind the tape in a half-overlapping m\.anner. Wind the tape in a half-overlapping manner. IMPORTANT : How to wind the supplied waterproof tape ● Also waterproof the 2P power cable (accessory), 4P alarm cable (accessory), and external connections in the same way. ● Stretch the tape by approx. twice (see the illustration) and wind it around the cable. Insufficient tape stretch causes insufficient waterproofing. ● To prevent the LAN cable hook from coming loose easily, fit the J LAN cable cover onto the pigtail cable as illustrated, and then slide it in the direction indicated by the arrow. The connector of the LAN cable used with this cam - era must meet the following restrictions. Height when inserted (From bottom to hook.): Max. 16 mm {5/8 inches} Connector width: Max. 14 mm {9/16 inches} ● To install this product outdoors, be sure to waterproof the cables. Waterproof grade (IEC IP66 or equiva - lent) is applied to this product only when it is installed correctly as described in these operating instructions and appropriate waterproof treatment is applied. The internal parts of base brackets are not waterproofed. 2x Str etch the tape to about twice. PoE device (hub) PCLAN cable (category 5 or better, \ftraight, S\bP: For Europe) Adju\ftment monitor LAN cable (category 5 or bet\,ter, \ftraight, S\bP: For Eu\,rope) LAN cable (category 5 or bet\,ter, \ftraight, S\bP: For Eu\,rope) Powered \fpeakerMicrophone Powered \fpeaker Microphone Adjustment monitor\b Recommended total \b extended cable len\f\bth* W\b-SF\b631L W\b-SF\b631 L IMPORTANT: ● The adjustment monitor is used for checking the adjustment of the angular field of view when installing the camera or when servicing. It is not provided for recording/monitoring use. ● Depending on the monitor, some characters (camera title, preset ID, etc.) may not be displayed on the screen. ● Use a switching hub or a router which is compliant with 10BASE-T/100BASE-TX. ● If a PoE hub is not used, each network camera must be connected to a 12 V DC power supply. ● When using 12 V DC, power supply from a PoE hub or router is not required. INITIAL SET button Dehumidifying device Auto focus (A\b) butt\pon SD slot 1 (SD1) SD slot 2 (SD2) SD ON/O\b\b button • \bRONT must posi- tioned in front of the camera (on the Panasonic logo sid\pe). Direction marker for installation (\bRONT ) Data Matrix: To our website *2 Direction marker for i\pnstallation (TOP) ● Points up when inst\palling to a wall. Dome cover Light-blocking rubber ring IR LED Azimuth adjustment ring Tilting tablePanning table Camera fixing screw The hook engages with the connector\p terminal J LAN cable cover C Fixing screws for attachment plate (accessory) Enclosure (Screw size 6.35 mm {1/4 inches} torx wrench) Camera B Attachment plate (accessory) A Base bracket (accessory) ACT indicator LINK indicator SD MOUNT indicator SD ERROR/A\b indicat\por *1 SDXC/SDHC/SD memory card is described as SD memory card. *2 Depending on the scanning application used, the Data Matrix may not be able to be read correctly. In this case, access the site by directly entering the following URL. http://security.panasonic.com/pss/security/support/qr_sp_select.html MONITOR OUT termin\pal (factory shipment: N\pTSC monitor) D 4P alarm cable (a\kccessory) GND (black) \fL\fRM \bN3, \fUX OUT (g\kray) (Terminal 3) \fL\fRM \bN2, \fL\fRM OUT (r\ked) (Terminal 2) \fL\fRM \bN1, D\fY/N\bGHT \b\kN (green) (Terminal\k 1) Connect the output cable of the AC adaptor to the 2P power cable. Power cable 12 V DC Red Positive Black Negative WV-SFV631L LAN cable (category 5 or better, straight, STP: For Europe) Use a LAN cable (category 5 or better, cross) when directly connecting the camera to a PC. * Recommended cable length from the speaker: less than 10 m {32.8 feet} Recommended cable length from the microphone: less than 1 m {3.28 feet} For U.S. and Canad\Pa: Pana\fonic Sy\ftem Comm\P\bnication\f Company of North Am\Perica, Unit of Pana\fonic Co\Prporation of North America www.panasonic.com/busi\pness/ \bor customer support\p, call 1.800.528.6\p747 Two Riverfront Plaza, Newark,\p NJ 07102-5490 Pana\fonic Canada Inc\P.5770 Ambler Drive,\p Mississauga, Ontario, L4\f 2T3 Ca\pnada (905)624-5010 www.panasonic.ca For E\brope and other co\bnt\Prie\f: 009100A200AF00A200B400B000AF00AA00A40061008400B000B300B100B000B300A200B500AA00B000AF http://panasonic.ne\pt Panasonic System Ne\ptworks Co., Ltd. \bukuoka, Japan Authorised Representative in EU: Panasonic Testing Centre Panasonic Marketin\pg Europe GmbH \finsbergring 15, 22525 Ha\pmburg, Germany * Use an external powered speaker. Connect the power cable IMPORTANT: ● The 12 V DC power supply shall be insulated from the commercial AC power. ● Be sure to use the 2P power cable provided with this product. ● Be sure to fully insert the 2P power cable into the 12 V DC power supply terminal. Otherwise, it may damage the camera or cause malfunction. ● When installing the camera, make sure that excessive force is not applied to the power cable. Caution: ● A READILY ACCESSIBLE DISCONNECT DEVICE SHALL BE INCORPORATED TO THE EQUIPMENT POWERED BY 12 V DC POWER SUPPLY. ● ONLY CONNECT 12 V DC CLASS 2 POWER SUPPLY (UL 1310/CSA 223) or LIMITED POWER SOURCE (IEC/EN/ UL/CSA 60950-1). Included Installat\ ion Instructions © Panasonic System\C Networks Co\f, Ltd\f \b\C013 \fIDE button (moves the camera \pto the “\fide” side)\p TELE button(moves the camera \pto the “Tele” side) I 2P power cable (accessory) RJ-45 (female) Network cable Alarm input/output cable Microphone/line input cable (white) Audio output cable (black)LAN cable (category 5 or better straight, STP: For Europe) 4P alarm cable (accessory) Power cable (12 V DC) 12 V DC (red) GND (black) Screen display top (TOP) NTSC/PAL switch
85 mm {3-11/32 inc\.hes} (85.\f mm {3-3/8 inc\.hes}) 25.4 mm {1 inch}*5 85 mm {3-11/32 inches} (85.\f mm {3-3/8 inches}) 138 mm {5-7/16 inches}25\f4 mm {1 inch}*5 138 mm {5-7/16 inches} 83.5 mm {3-9/32 inches} 4\f mm {1-13/1\f inches} 25.4 mm {1 inch}*5 \f3 mm {2-15/32 inches} 25.4 mm {1 inch}*5\f3 mm {2-15/32 inches} 83.5 mm {3-9/32 inches}25.4 mm {1 inch}*5 108.5 mm {4-9/32 inche\f} 70 mm {2-3/4 inche\f}25.4 mm {1 inch}*5 \bo\fition A \bo\fition D \bo\fition B \bo\fition C \bo\fition E \bo\fition F Attachment plate (\iaccessory) Fi\fing screws for att\iachment plate\b \f4 (\iM4, locally procur\ied) T wo-gang junction bo\f 46 mm {1-13/16 inch\ies } 83.5 mm {3-9/32 inches} In\ftallation Step2 Fixing the bracketsStep1 Preparations The installation tasks are explained using 4 steps. There are 4 methods to install the camera to a ceiling or wall as described below . Prepare the required parts for each installation method before starting the installation. The following are the requirements for the various installation methods. Installation method Recommended screw Minimum pull-out strength (per 1 pc.) [1] Mount the camera on the two-gang junction box using the attachment plate. M4 screws x 4 196 N {44 lbf} [2] Directly mount the camera onto the ceiling or wall using the attachment plate (when wiring can be installed in the ceiling or wall). M4 screws x 4 196 N {44 lbf} [3] Mount the camera onto the ceiling or wall using the base bracket (when conduits are used for wiring, or when there is no space available for wiring in the ceiling or the wall).* 1 M4 screws x 4 196 N {44 lbf} [4] Mount the camera embedded to a ceiling using the WV-Q169A (ceiling mount bracket: approx. 705 g {1.55 lb}).* 1*2— There is sufficient strength in the ceiling *1 Use 4 screws (M4 × 8 mm, accessory) to fix the attachment plate to the base bracket or WV-Q169A. *2 For information on how to mount the camera embedded to a ceiling using WV-Q169A, refer to the Instruction Manual provided with the WV-Q169A (ceiling mount bracket). IMPORTANT: ● Procure 4 screws (M4) to secure the attachment plate (accessory) or base bracket (accessory) to a ceiling or a wall. ● The minimum required pull-out capacity of a single screw or anchor bolt is 196 N {44 lbf} or more when mounting with the installation method [1] to [3] above. ● When mounting the camera on a concrete ceiling, use an AY plug bolt (M4) for securing. (Recommended tightening torque: 1.6 N·m {1.18 lbf·ft}) ● Select screws according to the material of the ceiling or wall that the camera will be mounted to. In this case, wood screws and nails should not be used. ● If a ceiling board such as plaster board is too weak to support the total weight, the area shall be sufficiently reinforced. [1] Using a two-gang junction box [2] Directly mount the camera to the ceiling or wall using the attachment plate [3] Mount the camera to a ceiling or a wall using base bracket < When using the conduit on the ceiling or wall for wiring> The base bracket can be fixed in any of the following 6 screwing positions according to ceiling and wall conditions. Match the hole used when installing the camera to any of positions A to F. A Remove the cap for the female thread for the conduit by using a hexagon wrench (ISO 2936, width across flats S=5 mm {3/16 inches}). B Mount the attachment plate and the base bracket. Attachment plate (accessory) \bixing screws for attach- ment plate: x4 (M4,\p locally procured) φ25.4 mm *3 {1 inch} φ73 mm *4 {2-7/8 inches} *5 The wiring hole diameter is 25.4 mm {1 inch}. Select any of the 2 base bracket fixture holes of G template B when installing the base bracket. After mounting the attachment plate, the mounting direction of the camera can be adjusted in 90° increments. *6 When attaching the base bracket to a one-gang junction box in Position E, secure the base bracket with 2 screws (M4, locally procured ).IMPORTANT: ● If open wiring is conducted, be sure to use conduits and run the cables inside the tubes to protect the cables from direct sunlight. ● Installation work shall be such that there is no exposure to water into the architecture through the conduits having been joined. Step1 Make sure all items are prepared before beginning installation. Step2 Mount the brackets to a ceiling or wall Step3 Connect cables, and then attach the camera to the mount bracket. Step4 Adjust the angle of view and focus, and then mount the enclosure. FRONT Cap for the female thread for the con- duit Base bracket (acce\pssory) \bixing screws (M4x4, locally\p procured) Minimum pull-out strength: 196 N {44.06 lbf} (per 1 pc.) \bixing screws for attachment \p plate: x4 (accessor\py) (Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}) Attachment plate (accessory) *3 If the mounting direction of the camera has already been determined Align the FRONT direction (the direction of FRONT marker on the camera that indicates the installation direction when installing the camera) of F template A with the desired direction, and drill through a 25.4 mm {1 inch} diameter hole. *4 If the mounting direction of the camera is not determined yet or if you want to change the direction of the camera after it has been installed If you want to be able to change the direction of the camera, drill through a 73 mm {2-7/8 inches} diameter hole in the center. By doing so you can adjust the mounting direction of the camera in 90° increments. Step3 Mount the camera to the attachment plate Step4 Adjustment A Check the position of attachment mounting screws on the rear side of the camera. B Connect cables to the camera according to the instructions in “Making connections”, and mount the camera by inserting the attachment mounting screws into the holes of the attach - ment plates. CLoosen the enclosure fixing screws. D Remove the enclosure from the camera, and secure the camera using camera fixing screws. Note: ● After cables have been connected to the camera, align the OPEN mark of the enclosure side panel with the protruding part of base bracket, insert 2 attachment mounting screws into the attachment plate, and rotate the camera approximately 15°. The LOCK mark is moved to the protruding part of base bracket and the camera is temporarily secured. (When directly attaching the attachment plate to a ceiling or wall, align the OPEN mark to the tab position of the attachment plate.) *The fixing angle of the camera can be rotated in 90° increments . Note: ● Loosen 4 enclosure fixing screws using the bit (accessory). IMPORTANT: ● Be sure to tighten the camera fixing screw. Failure to observe this may cause camera trouble due to camera falling. (Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}) A Turn on power for the camera by either connecting a LAN cable or a 12 V DC power cable. B Connect the MONITOR OUT conversion plug (accessory) to the MONITOR OUT terminal of the camera, and then connect the monitor for adjustment with a RCA pin cable (locally procured). ● The camera is set to be connected to the NTSC monitor for adjustment at factory shipment. Horizontal position (Panning): ±180° Vertical position (Tilting): 0° to 85° Image tilt adjustment: -45°(Left) to +300°(Right) ● To remove the SD memory card, hold down the SD ON/OFF button for about 2 seconds. When the flashing SD MOUNT indicator goes out, you can remove the SD memory card. ● After the SD memory card has been replaced, press the SD ON/OFF button, and make sure the SD MOUNT indicator is continually lit. (If you replace both SD memory cards, press the SD ON/OFF button after replacing the cards.) ● If you do not press the SD ON/OFF button after replacing the SD memory card, the SD MOUNT indicator is continually lit approximately 5 minutes later. ● When adjusting the viewing angle, make sure not to touch the light-blocking rubber ring or IR LED cover. Fingerprints or dirt can reduce the quality of viewed images. C Adjust the angle of the camera with the tilt table, pan table, and azimuth adjust - ment ring, and then adjust the viewing angle by pressing the WIDE or TELE buttons. D Insert an SD memory card into the slot, if necessary. E Disconnect the monitor for adjustment after adjusting the focus by pressing the AF button. F Attach the enclosure. (Remove the protection film from inside of the dome cover, match the protruding part of base bracket to LOCK mark of the enclosure, and then attach the enclosure.) E MONITOR OUT conve\prsion plug (accessory) NTSC⇔PA L \fIDE Note: ● When the screen size is adjusted using the WIDE ⇔TELE button, the camera’s focus is automatically adjusted with the basic focus adjustment function each time the WIDE⇔TELE button is pressed. ● When mounting the camera on a ceiling, adjust the tilt angle so that the TOP mark above the lens always comes to the top side. ● When the camera is installed to a wall, the image is reversed in the default settings. To correct the way the image is displayed, rotate the azimuth adjustment ring 180° clockwise, or select “On” for “Upside-down” from the setup menu. For information about performing the “Upside-down” setting from the setup menu, refer to the Operating Instructions (included in the CD-ROM). ● Remove the camera using the reverse order of the installation procedures. IMPORTANT: ● Securely tighten all the fixing screws (x4) of enclosure. Otherwise, camera dropping may result in injury. (Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}) ● Defocus may be caused by the reinstalled enclosure. In this case, perform the auto focus function from the setup menu. ● Remove the cover film from the dome cover. Approx. 15° Enclosure Camera fixing screw Attachment mountin\pg screws IMPORTANT: ● Disconnect the 12 V DC power source and PoE power source to prevent power from being supplied during mounting work. ● Enclosure is fixed at the installation auxiliary wire to the camera body , please do not remove the installed auxiliary wire. ● For installations on the wall, to prevent water from accumulating on the surface of the dehumidifying device, install the camera so that the dehumidifying device does not face up. If water accumulates on the surface of the dehumidifying device, it cannot function properly. A\b SD1, SD2 TELE < When drilling a hole through the ceiling or wall for wiring> ● The female thread for conduit is compliant with ANSI NPSM (parallel pipe threads) 3/4 inches or G3/4 of ISO 228-1. *6 After installing the camera, refer to “Configure the settings of the camera (leaflet) ” and perform the camera settings. Tab position of the attach- ment plate (x4) Conduit Protruding part (x4) Direction marker for installation (\bRONT ) ● Insert the SD memory card with its label facing down. 46 mm {1-13/16 inches} 83.5 mm {3-9/32 inches}