Have a look at the manual Panasonic Monitoring Software Digital Disk Recorder Wj Rt416 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 Configure the Network Settings With the following network environment, it is not necessary to configure the network settings. It is possible to config- ure the settings or operate the recorder using the monitoring software after completing the connection. IP Address: 192.168.0.2 - 192.168.0.249, 192.168.0.251 - 192.168.0.254 Subnet Mask: 255.255.255.0 Gateway Address: 192.168.0.1 When the network settings are different from the settings above, configure the network settings of the recorder and the PC. Configure the network settings of the recorder Use the buttons on the front panel of the recorder to conform the network settings to the network environment of the PC. Refer to the installation guide of the recorder for further information about the network settings (The Configure the network settings [Network Setup] section under the Configure the settings relating to communication with other devices [Communication Setup] chapter in the descriptions of Setup Menu). Configure the network settings of a PC Change the TCP/IP setting of the PC to conform to the settings of the recorder. It is required to set the IP address of the PC to 192.168.0.XX (a number from 2 to 254 except 250) to access the recorder. Screenshot 1 Start just after the PC is started up. Important: Log in to the PC as an administrator. Step 1 On the taskbar, click Start, and then click the Control Panel.
12 Screenshot 2 The control panel will be displayed. Step 2 Click the Network and Internet Connections icon. Screenshot 3 The Network and Internet Connections window will be displayed. Step 3 Click Network Connections. Screenshot 4 The Network Connections window will be displayed. Step 4 Double click Local Area Connection.
13 Screenshot 5 The Local Area Connection Status window will be dis- played. Step 5 Click Properties. Screenshot 6 The Local Area Connection Properties window will be displayed. Step 6 Click Internet Protocol (TCP/IP), and then click Properties. Screenshot 7 The Properties window of Internet Protocol (TCP/IP) will be displayed. Step 7 Click Use the following IP address and enter the IP address and the subnet mask as follows; • IP Address: 192.168.0.9 • Subnet Mask: 255.255.255.0 Step 8 Click the OK button and close the window.
14 Settings relating to the connection with the recorder Before operating on the operation window, configure the network settings between the PC and the recorder. Screenshot 1 Click the [Monitor System Setup] button. The pop-up menu will be displayed. Select Recorder Setup under Monitor System Config. The Recorder Setup window will be displayed. Step 1 Click the [Insert] button in the Recorder Info. section, and then register the recorder information. The password is arbitrary. Important: Operable functions of the recorder vary depending on the user level. Depending on the settings of the recorder, it is possible to restrict users to monitor images from the cameras by setting the password of the user level Viewer or Operator. By setting the password of the user level Viewer, it is possible to restrict users to operate the cameras. (Users whose user level is Manager can configure the settings of the cameras.) The default password is different according to the user level as follows. Manager1: 12345678 Operator1: 123456 Viewer1: 1234 Notes: •The default of Server Port of the recorder is 2000, and of IP Address is 192.168.0.250. • Up to 12 characters can be entered for Name. Step 2 Click the [OK] button. Step 3 Click the [Close] button. Note: Refer to the installation guide of the recorder for fur- ther information about the connection works of the recorder and the PC.
15 Monitor Live Images Screenshot 3 The Connect window will be displayed. Step 3 Select the recorder to access and the desired camera channel. Notes: • Only the recorders registered in advance can be selected on the Connect window. Refer to page 14 for further information. • The password registered when registered the recorder will be entered automatically. • When displaying images from 5 or more camera channels of the same recorder, or when displaying recorded images in an area on a multi-screen, only I-frame will be displayed in all areas on a multi- screen and audio may not be heard. It is possible to display live images on a single screen or a multi-screen in the image display area. To monitor live images from the cameras, select the desired camera connected to the recorder first. Screenshot 1 Start operation when the operation window is being dis- played. Step 1 Right-click on a blank area in the image display area. Screenshot 2 The pop-up menu will be displayed. Step 2 Select Connect.
16 Switch the image display area between a single screen and a multi-screen Display images on a single screen in the image display area Click the desired area selection button. →The selected area will be displayed on a single screen in the image display area. The image display area will be switched to a single screen by clicking one of the area selection buttons when a multi-screen is displayed in the image display area. The area selection buttons will change as follows to indicate the current status. (a) : This area is displayed in the image display area and currently selected. (b) : This area is displayed in the image display area and currently not selected. (c) : This area is not displayed in the image display area, or currently being used for the sequential display. Display images on a multi-screen in the image display area Click the desired multi-screen selection button. →The selected multi-screen will be displayed in the image display area. (4-screen): Each time this button is clicked, the displayed area will change as follows. 1 - 4 →5 - 8 →9 - 12 →13 - 16 →1 - 4 →··· (6-screen): Each time this button is clicked, the displayed area will change as follows. 1 - 6 →7 - 12 →1 - 6 →7 - 12··· (9-screen): Areas 1 - 9 will be displayed in the image display area. (16-screen): Areas 1 - 16 will be displayed in the image display area. Check the status of the camera The status of the camera respective to the area can be check with the displayed icon. (No icon): Displaying of live images or playback of recorded images are available in this area. : Live images from the camera are being displayed in this area. When this icon is blinking, images in the sequential display are being displayed in this area. : Recorded images are being played in this area. Step 4 Click the [OK] button. →The connection status window will be displayed. When the connection is established, images from the selected camera will be displayed in the selected area in the image display area.
17 Screenshot 1 Start operation when the operation window is being dis- played. Step 1 Right-click on the displayed image that is from the cam- era to be disconnected. Screenshot 2 The pop-up menu will be displayed. Step 2 Select Disconnect. →The connection with the selected camera will be dis- connected. : The camera respective to this area is in the alarm status. : Live images or recorded images currently being displayed are being saved. When this icon is blinking, images are being recorded by the alarm recording. Refer to pages 44 and 45 for further information about the alarm recording. Temporarily change color of text displayed in the image display area When right-clicking on the text displayed on the image display area, the pop-up menu will be displayed. Select White, Magenta or Bright Green to change the color of the text temporarily. Control the cameras The camera from which images are being displayed in the image display area can be controlled using the control panel (page 24). When displaying images on a single screen or on a 4-screen, it is also possible to pan/tilt the camera by clicking on the image displayed in the image display area. Refer to page 26 for further information. Disconnect the connection with camera
18 Login to the recorder Log in the recorder as follows. Screenshot 1 Click the [Login] button. →The Login window will be displayed. Important: Depending of the firewall setting of Windows XP SP2, recorder information may sometimes not be displayed. Refer to page 6 for further information. Step 1 Select the desired recorder and enter the password of the user level Manager. Note: Only the recorders registered in advance can be selected on the Login window. Refer to page 14 for further information. Step 2 Click the [OK] button. →The connection status window will be displayed. When the connection is established, the recorder information (page 9) will be displayed on the left side of the operation window. The [Login] button on the operation window will also change to the [Logout] button . Click this but- ton to log out of the recorder.
19 Play recorded images on the recorder Recorded images can be played from the search result window. It is possible to search recorded images to be played by designating multiple search filters (List Search) or by designating the start time and date of recording (Time & Date Search). To play recorded images, log in the recorder as Manager. Refer to page 18 for how to log in the recorder. Important: It is impossible to play recorded images which is currently being played or copied on the recorder. Note: When displaying images from 5 or more camera channels of the same recorder, or when displaying recorded images in an area on a multi-screen, only I-frame will be displayed in all areas on a multi-screen (audio may not be heared when displaying live images). Play recorded images from the search result window displayed after searching with the designated search filters (List Search Playback) Screenshot 1 Start operation when the operation window is being dis- played. Step 1 Right-click on a blank area in the image display area. Screenshot 2 The pop-up menu will be displayed. Step 2 Select List Search Playback.
20 Screenshot 3 The List Search window will be displayed. Step 3 Set the desired search filter. Camera Check the radio button of the desired camera channel to be searched.Filtering Off: Searches without filtering Manual: Searches for only images recorded by the manual recording Timer: Searches for only images recorded by the timer recording Alarm: Searches for only images recorded by the alarm recording (triggered by a terminal input, VMD and a command alarm reception) Terminal: Searches for only images recorded by the alarm recording triggered by a terminal input VMD: Searches for only images recorded by the alarm recording triggered by VMD Com: Searches for only images recorded by the alarm recording triggered by a command alarm reception Start/End Designate the time period to be searched by entering the start and end time and date. Step 4 When the search filters are set, click the [OK] button. Screenshot 4 The search result window will be displayed. Step 5 Select the desired recorded images to be played. Note: It is possible to select multiple search results by clicking them while pressing the [Ctrl] key on the keyboard. Step 6 Click the [Play] button. →Playback of the selected recorded images will start in the area selected in step 1. Refer to page 28 for how to perform playback opera- tions using the control panel. Note: The latest 5 000 recorded images will be displayed in the list form.