    							Model No. AW-LK30
    Before attempting to connect or operate this product,
    please read these instructions completely
    and save this manual for future use.
    Lens Controller 
    						
    							-2-
    NOTE:This equipment has been tested and found to com-
    ply with the limits for a Class A digital device, pursuant to
    part 15 of the FCC Rules. These limits are designed to pro-
    vide reasonable protection against harmful interference
    when the equipment is operated in a commercial environ-
    ment. This equipment generates, uses, and can radiate
    radio frequency energy and, if not installed and used in
    accordance with the instruction manual, may cause harmful
    interference to radio communications. Operation of this
    equipment in a residential area is likely to cause harmful
    interference in which case the user will be required to cor-
    rect the interference at his own expense.
    This Class A digital apparatus complies with Canadian
    ICES-003.
    Cet appareil numérique de la classe A est conforme à la
    norme NMB-003 du Canada.
    WARNING:
    TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
    The lightning flash with arrowhead sym-
    bol, within an equilateral triangle, is
    intended to alert the user to the pres-
    ence of uninsulated dangerous voltage
    within the products enclosure that may
    be of sufficient magnitude to constitute a
    risk of electric shock to persons.
    The exclamation point within an equilat-
    eral triangle is intended to alert the user
    to the presence of important operating
    and maintenance (servicing) instructions
    in the literature accompanying the appli-
    ance.The information marking of this product may be found on the
    bottom of the unit.
    The serial number of this product may be found on the bot-
    tom of the unit.
    You should note the serial number of this unit in the space
    provided and retain this book as a permanent record of your
    purchase to aid identification in the event of theft.
    Model No.
    Serial No.
    CAUTION:
    TO REDUCE THE RISK OF ELECTRIC SHOCK, DO
    NOT REMOVE COVER (OR BACK). NO USER SER-
    VICEABLE PARTS INSIDE.
    REFER SERVICING TO QUALIFIED SERVICE PER-
    SONNEL.
    CAUTION
    RISK OF ELECTRIC SHOCK
    DO NOT OPEN
    SA 1965
    SA 1966
    For U.S.A
    For CANADA 
    						
    							-3-
    CONTENTS
    WARNING/CAUTION FOR SAFETY  .......................................................................................................................................... 4
    PREFACE .................................................................................................................................................................................. 5
    PRECAUTIONS ......................................................................................................................................................................... 5
    MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ................................................................................................... 6
    INSTALLATION ......................................................................................................................................................................... 8
    SPECIFICATIONS ..................................................................................................................................................................... 9
    STANDARD ACCESSORIES  ................................................................................................................................................... 10 
    						
    							-4-
    WARNING/CAUTION FOR SAFETY
    WARNING
    • Refer all servicing to qualified personnel
    To reduce the risk of electric shock, dont remove
    cover or back, unless you are a qualified personnel.
    Refer all mountings, connections, servicing to quali-
    fied service personnel.
    • No water or moisture inside
    Do not let water or moisture into the product, or
    expose it to moisture, to prevent a fire and electric
    shock.
    • If you see smoke or smell an odor from the product,
    if water or other foreign matter gets inside, if it is
    damaged by dropping, or if you find anything
    wrong with it, immediately stop using it.
    • Do not disassemble or modify the product to
    prevent a fire and electric shock.
    CAUTION
    • Do not drop the product, do not expose it to strong
    shock, or do not step on it, to prevent a fire and
    injuries.
    • Do not install the product at a place full of moisture
    and dust, which may cause a fire and electric
    shock. 
    						
    							-5- The AW-LK30 is a lens controller for motor-driven lens-
    es that have a zoom/focus control cable (fitted with a
    12-pin female connector).  Connected to a lens control
    cable, it permits local control of lens zoom, focus, and
    iris. (Applicable lenses:  Panasonic AW-S14XBMD, AW-
    LZ10MD6, AW-LZ14MD55, etc.)
    PREFACE
    PRECAUTIONS
    • Power Off Before Plugging or Unplugging
    Be sure to switch power off before plugging or
    unplugging the cable.
    • Handle with Care
    Be careful not to drop the unit, and not to expose it
    to strong shock or vibration.  This is important to
    prevent the unit from malfunction.• Little Moisture and Dust
    Avoid using the unit at a humid and dusty place
    because moisture and dust adversely affect the
    parts inside.
    • Operating Temperature Range
    Avoid using the unit at a cold place below –10°C or
    at a hot place over +45°C because very low or high
    temperature adversely affects the internal parts. 
    						
    							-6-
    MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
    TELE WIDEIRIS ZOOM
    H L
    OPEN CLOSE
    AUTO
    MANU
    FAR
    H L
    NEARFOCUS
    SPEED
    qZoom Speed Control [ZOOM SPEED L/H]
    To adjust lens zoom control speed.  Turning it
    clockwise increases speed.
    wZoom Control Tele Switch [ZOOM TELE]
    The lens zooms in the telescopic direction while the
    switch is kept depressed.eZoom Control Wide Switch [ZOOM WIDE] 
    The lens zooms in the wide angle direction while
    the switch is kept depressed.
    rFocus Speed Control [FOCUS SPEED L/H]
    To adjust lens focus control speed.  Turning it
    clockwise increases speed. 
    						
    							-7- tFocus Control Near Switch [FOCUS NEAR]
    The lens focus draws near while the switch is kept
    depressed.
    yFocus Control Far Switch [FOCUS FAR]
    The lens focus moves far while the switch is kept
    depressed.
    uIris Auto/Manual Switch [IRIS AUTO/MANU]
    At AUTO, the iris is automatically controlled (ALC).
    At MANU, the iris can be adjusted with Iris Control
    i.
    iIris Control [IRIS CLOSE/OPEN] 
    The iris can be adjusted from CLOSE to OPEN or
    vice versa when Iris AUTO/MANU switch uis at
    MANU.  Turn it counterclockwise to close the iris, or
    clockwise to open it.
    oLens Control Connector
    Connect the zoom/focus control cable of your lens
    to it.!0Clamper
    Use it to clamp the lens controller to the grip of a tri-
    pod, for example.
    !1Clamp Screw
    Tighten this screw to fasten the lens controller to the
    grip of a tripod, for example.
    If your lens has zoom, focus and iris AUTO/MANU
    switches, set all the AUTO/MANU switches to AUTO.
    Caution 
    						
    							-8-
    INSTALLATION
    – +
    MENU
    ITEM/AWC
    YES/ABC
    NO/BAROPTION  CARD
    VIDEO  OUT
    I/F  REMOTE
    G/L IN
    IRIS
    DC12V IN
    Remote (zoom/focus 
    control) cable
    Camera cable
    Zoom lens
    Camera
    To Iris connector
    TELE WIDEIRIS ZOOM
    H L
    OPEN CLOSE
    AUTO
    MANUFAR
    H L
    NEARFOCUSSPEED
    Tripod grip 
    or the like 
    						
    							-9- Power supply: 12 V DC, 60 mA (supplied from lens)
    Lens control: Zoom: Speed, tele/wide
    Focus: Speed, near/far
    Iris: Auto/manual, open/close
    Connecting cable length: 190 cm
    Operating temperature range: –10°C to +45°C (14°F to +113°F)
    Humidity: 30% to 90%
    Dimensions: 90 (W) x 40 (H) x 70 (D) mm [3-17/32” x 1-9/16” x 2-3/4”]
    Weight: 400 g(0.9 lbs.)
    Finish: AV ivory paint (close to Munsell 7.9Y6.8/0.8)
    Weight and dimensions indicated are approximate.
    Specifications are subject to change without notice.
    SPECIFICATIONS 
    						
    							-10-
    STANDARD ACCESSORIES
    Clamper  ........................................ 1 each, right and left
    Clamp screw ........................................................... 1 pc
    Mounting screw  .................................................... 2 pcs 
    						