Have a look at the manual Panasonic LCD Projector Pt Vw350zu Pt Vx420zu Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

Contents of mail sent Example of E-mail sent when E-mail is set Mail with the contents shown below is sent when the e-mail settings have\ been established. === Panasonic projector report(CONFIGURE) === Projector Type : PT-VW350 Serial No : 000000000 ----- E-mail setup data ----- TEMPERATURE WARNING SETUP MINIMUM TIME at [ 60] minutes interval INTAKE AIR TEMPERATURE Over [ 32degC / 89degF ] ERROR [ OFF ] LAMP RUNTIME [ OFF ] at REMAIN [ 400] H LAMP RUNTIME [ OFF ] at REMAIN [ 200] H INTAKE AIR TEMPERATURE [ OFF ] ----- check system ----- FAN [ OK ] INTAKE AIR TEMPERATURE [ OK ] EXHAUST AIR TEMPERATURE [ OK ] OPTICS MODULE TEMPERATURE [ OK ] LAMP REMAIN TIME [ OK ] LAMP STATUS [ OK ] APERTURE (CONTRAST-SHUTTER) [ OK ] AIR FILTER [ OK ] (Error code 00 00 00 00 00 00 00 00) Intake air temperature : 31 degC / 87 degF Exhaust air temperature : 37 degC / 98 degF Optics module temperature : 39 degC / 102 degF PROJECTOR RUNTIME 800 H LAMP NORMAL 500 H LAMP ECO 700 H LAMP REMAIN 4000 H -------- Current status --------- MAIN VERSION 1.00 NETWORK VERSION 1.00 SUB VERSION 1.00 LAMP STATUS LAMP=ON INPUT RGB SIGNAL NAME XGA6 SIGNAL FREQUENCY 0.00kHz / 0.00Hz ----- Wired Network configuration ----- DHCP Client OFF IP address 192.168.10.100 MAC address 04:20:9A:00:00:00 ----- Memo ----- ENGLISH - 91 Chapter 4 Settings - [NETWORK] menu

Example of E-mail sent for an error Mail with the contents shown below is sent when an error has occurred. === Panasonic projector report(ERROR) === Projector Type : PT-VW350 Serial No : 000000000 ----- check system ----- FAN [ OK ] INTAKE AIR TEMPERATURE [ OK ] EXHAUST AIR TEMPERATURE [ OK ] OPTICS MODULE TEMPERATURE [ OK ] LAMP REMAIN TIME [ OK ] LAMP STATUS [ OK ] APERTURE (CONTRAST-SHUTTER) [ OK ] AIR FILTER [ FAILED ] (Error code 00 00 00 20 00 00 00 00 ) Intake air temperature : 31 degC / 87 degF Exhaust air temperature : 37 degC / 98 degF Optics module temperature : 39 degC / 102 degF PROJECTOR RUNTIME 800 H LAMP NORMAL 500 H LAMP ECO 700 H LAMP REMAIN 4000 H -------- Current status --------- MAIN VERSION 1.00 NETWORK VERSION 1.00 SUB VERSION 1.00 LAMP STATUS LAMP=OFF INPUT RGB ----- Wired Network configuration ----- DHCP Client OFF IP address 192.168.10.100 MAC address 04:20:9A:00:00:00 ----- Memo ----- [Port set up] page Set the port number used for command control. Click [Detailed set up] → [Port set up]. 1 [COMMAND PORT] Set the port number used for command control. 2 [Wake on LAN PORT] When [STANDBY MODE] is set to [NETWORK], set the port number used for the Wake on LAN function. 3 [Submit] Update the settings. 92 - ENGLISH Chapter 4 Settings - [NETWORK] menu

[ECO management set up] page You can make settings for the ECO management function of the projector. Click [Detailed set up] → [ECO management set up]. 1 [LAMP POWER] Selects the [LAMP POWER] setting. 2 [AUTO POWER SAVE] Select [ON] to set [AMBIENT LIGHT DETECTION], [SIGNAL DETECTION], and [AV MUTE DETECTION]. 3 [AMBIENT LIGHT DETECTION] Enable ([ON])/disable ([OFF]) the ambient light detection function. 4 [SIGNAL DETECTION] Enable ([ON])/disable ([OFF]) the signal detection function. 5 [AV MUTE DETECTION] Enable ([ON])/disable ([OFF]) the AV mute detection function. 6 [POWER MANAGEMENT] Select the power consumption mode. 7 [TIMER] Select the time that the lamp is turned off when the POWER MANAGEMENT function is using. 8 [Submit] Update the setting. Note f For detailed description of each setting item, refer to the [PROJECTOR SETUP] menu of the projector → [ECO MANAGEMENT] ( x page 71). [Change password] page Click [Change password]. 1 [Administrator] Used to change the setting of [Administrator]. 2 [User] Used to change the setting of [User]. 3 [Next] Used to change the setting of the password. ENGLISH - 93 Chapter 4 Settings - [NETWORK] menu

[Administrator] account 1 [Account : Administrator] Displays the account to change. 2 [Current] [User name] Enter the user name before the change. 3 [Current] [Password] Enter the current password. 4 [New] [User name] Enter the desired new user name. (Up to 16 characters in single byte) 5 [New] [Password] Enter the desired new password. (Up to 16 characters in single byte) 6 [New] [Password (Retype)] Enter the desired new password again. 7 [OK] Determines the change of password. [User] account 1 [Account : User] Displays the account to change. 2 [New] [User name] Enter the desired new user name. (Up to 16 characters in single byte) 3 [New] [Password] Enter the desired new password. (Up to 16 characters in single byte) 4 [New] [Password (Retype)] Enter the desired new password again. 5 [OK] Determines the change of password. [Change password] (For user rights) Only the change of password is enabled under the user rights. 94 - ENGLISH Chapter 4 Settings - [NETWORK] menu

1 [Old Password] Enter the current password. 2 [New Password] Enter the desired new password. (Up to 16 characters in single byte) 3 [Retype] Enter the desired new password again. 4 [OK] Determines the change of password. Note f To change the account of the administrator, you must enter the [User name] and [Password] in [Current]. [Crestron Connected(TM)] page The projector can be monitored/controlled with Crestron Connected™. To start the Crestron Connected™ control page from the web control screen, you need to access with the administra\ tor rights. (For user rights, the [Crestron Connected(TM)] button is not displayed on the web control screen.) The control page of Crestron Connected™ is displayed by clicking [Crestron Connected(TM)] . It is not displayed if Adobe ® Flash® Player is not installed on the computer used, or the browser used does not support Flash. In that case, click [Back] on the control page to go back to the previous page. Control page 1 [Tools], [Info], [Help] Tabs for selecting the setting, information or help page of the projector. 2 [POWER] Turns on/off the power. 3 [VOL DOWN], [AV MUTE], [VOL UP] Adjusts the volume. Switches the AV mute function on/off. 4 [Input Select] Controls input selection. Not available when the power of the projector is turned off. 5 Menu screen control buttons Navigates the menu screen. 6 Freeze/image quality adjustment Controls items related to freeze/image quality. 7 [Back] Performs return to the previous page. [Tools] page Click [Tools] on the control page. ENGLISH - 95 Chapter 4 Settings - [NETWORK] menu

1 [Control System] Set the information required for communicating with the controller to be connected with the projector. 2 [User Password] Set the user rights password for the Crestron Connected™ control page. 3 [Admin Password] Set the administrator rights password for the Crestron Connected™ control page. 4 Network status Displays the settings of wired LAN. [DHCP] Displays the current setting. [IpAddress] Displays the current setting. [SubnetMask] Displays the current setting. [DefaultGateway] Displays the current setting. [DNSServer] Displays the current setting. 5 [Exit] Returns to the control page. [Info] page Click [Info] on the control page. 1 [Projector Name] Displays the projector name. 2 [Mac Address] Displays the MAC address. 3 [Lamp Hours] Displays the runtime of the lamp (converted value). 4 [Power Status] Displays the status of the power. 5 [Source] Displays the selected input. 6 [Lamp Mode] Displays the setting status of [LAMP POWER] (x page 71) . 7 [Error Status] Displays the error status. 8 [Exit] Returns to the control page. [Help] page Click [Help] on the control page. The [Help Desk] window is displayed. 1 [Help Desk] Send/receive messages to/from an administrator who uses Crestron Connected™. 96 - ENGLISH Chapter 4 Settings - [NETWORK] menu

Chapter 5 Maintenance This chapter describes methods of inspection when there are problems, ma\ intenance, and replacement of the units. ENGLISH - 97

Lamp and Warning Indicators When an indicator lights up If a problem should occur inside the projector, the lamp indicator and the warning indicator will inform you by lighting or blinking. Check the status of the indicators and remedy the indicated problems as follows. Attention f Before you take a remedial measure, follow the procedure of switching the power of f indicated in “Powering Off the projector”. (x page 39) Lamp indicator Indicator Lighting in red. Blinking in red. Status Time to replace the lamp unit. A problem is detected in the lamp or the power supply for the lamp. Check f Was [REPLACE LAMP] displayed when you turned on the power? f The indicator lights up when the runtime of the lamp unit has reached 5 000 hours (when [LAMP POWER] is set to [NORMAL]). f Have you turned on the power again immediately after turning it off? f Some error has occurred in the lamp circuit. Check for fluctuation (or drop) in the source voltage. Remedy f Replace the lamp unit. f Wait a while until the luminous lamp cools off, and then turn on the power. f Turn off the projector, and unplug the AC power cord, and consult your dealer. Note f If the lamp indicator is still lighting or blinking after taking the preceding measures, ask your dealer for repair . Warning indicator IndicatorLighting in red. Blinking in red. Blinking in red. (Slow) Status Internal temperature is high (warning). Internal temperature is high (standby status). The projector detects an abnormal condition and cannot be turned on. Check f Is the air intake/exhaust port blocked? f Is the room temperature high? f Is the air filter unit dirty? _ Remedy f Remove any objects that are blocking the air intake / exhaust port. f Install the projector in a location with an ambient temperature of 0 °C (32 °F) to 40 °C (104 °F). f Do not use the projector at high altitudes of 2 700 m (8 858 ') or higher above sea level. f Replace the air filter unit. ( x page 99) f If the projector is turned off again, unplug the AC power cord and contact the dealer or the service center for service and checkup. Note f If the warning indicator is still lighting or blinking after taking the preceding measures, ask your dealer for repair. Lamp indicator Warning indicator 98 - ENGLISH Chapter 5 Maintenance - Lamp and Warning Indicators

Maintenance/replacement Before performing maintenance/replacement f When you perform maintenance or replacement of the parts, make sure to turn of f the power and disconnect the power plug from the wall outlet. (x pages 35, 39) f Be sure to observe the procedure “ Powering Off the projector” (x page 39) when performing power supply operation. Maintenance Outer Case Wipe off dirt and dust using a soft dry cloth. f If the dirt is persistent, soak the cloth with water and wring it thorou\ ghly before wiping. Dry off the projector with a dry cloth. f Do not use benzene, thinner or rubbing alcohol, other solvents or household cleaners. Using them may cause deterioration of the outer case. f When using chemical treated dusters, follow its instruction. Front glass surface of the lens Wipe off the dirt and dust off the front surface of the lens with soft clean cloth. f Do not use a cloth that has an abrasive surface or a cloth that is moist\ , oily or covered with dust. f Do not use excessive force when wiping the lens as it is fragile. f Do not use benzene, thinner or rubbing alcohol, other solvents or household cleaners. Using them may cause deterioration of the lens. Attention f The lens is made of glass. Impacts or excessive force when wiping may scratch its surface. Please handle with care. Replacing the unit Air filter unit The air filter prevents dust from accumulating on the optical elements inside the projector . Should the air filter become clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat buildup and adversely affect the life of the projector. If the air filter unit become clogged, it will result in internal heat buildup, the power of the projector may be turned of f for safety. If a warning message appears on the screen, replace the air filter immediately . Consult your dealer to purchase a replacement air filter unit (ET -RFV300). Removing the air filter unit 1) Remove the air filter cover. (Fig.1) f Open the air filter cover in the direction of the arrow and remove it. 2) Remove the air filter unit. f Hold the tab of the air filter unit and pull out in the direction of the arrow . (Fig.2) f After removing the air filter unit, remove foreign objects and dust from the air filter compartment and the projector ’s air intake port if there are any. Air filter unit Ta b Fig.1 Fig.2 Air filter cover ENGLISH - 99 Chapter 5 Maintenance - Maintenance/replacement

Attaching the air filter unit 1) Attach the unused air filter unit to the projector. f Hold the air filter unit that the tab is in up-left side in the figure, put the right side in the figure first, and press the tab side until make a click sound. f Please press the tab of the air filter unit other than the pleated filter during installation. 2) Install the air filter cover. f Perform Step 1) in “Removing the air filter unit” ( x page 99) in the reverse order to close the air filter cover and press it firmly until make a click sound. f Make sure that the air filter cover is closed tightly. Resetting the filter counter Be sure to reset the filter counter after replacing the air filter unit. 1) Connect the power plug, press the power < v/b> button on the control panel or on the remote control. 2) Press the button to display the main menu, then press as to select [PROJECTOR SETUP]. 3) Press the button, press as to select [FILTER COUNTER]. 4) Press the button, press as to select [FILTER COUNTER RESET]. 5) Press the button. f [FILTER COUNTER RESET] confirmation is displayed. 6) Press qw to select [OK], then press the button. f The filter usage time is 0 after reset. Attention f Turn off the power before you replace the air filter unit. f When attaching the air filter unit, make sure that the projector is stable, and work in an environment that is safe, even in the event of the air filter unit dropping. f Make sure that the air filter unit is properly attached before using the projector . If it is not attached, the projector will suck in dirt and dust causing a malfunction. f Do not put anything into the air vents. Doing so may result in malfuncti\ on of the projector. f The air filter unit to be replaced should be an unused product. f After replacing the air filter, reset the filter counter. Otherwise, “FILTER COUNTER has reached the set time.” will appear on screen. Note f The replacement cycle of the air filter unit varies greatly depending on the usage environment. Lamp unit The lamp unit is a consumable component. Refer to “When to replace the lamp unit” ( x page 101) for details about the replacement cycle. It is recommended to ask an authorized engineer to replace the lamp unit. Contact your dealer . Consult your dealer to purchase a replacement lamp unit (ET-LAV300). Warning Do not replace the lamp unit when it is hot. (Wait at least 1 hour after use.) The inside of the cover can become very hot, take care to avoid burn inj\ uries. Ta b 100 - ENGLISH Chapter 5 Maintenance - Maintenance/replacement