    Have a look at the manual Panasonic LCD Projector PT-FW100NT PT-F100NT PT-F100 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
    11/16 
     
     
    2.34.  Query White Balance - B 
    Hexadecimal 02h 51h 57h 42h 03h
    Character  Q W B  
    „  Response (Callback) In the period when the command can be accepted 
    Hexadecimal 02h *1  *3  *5 03h 
    Character  *2 *4 *6  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes No  No  Yes Yes 
    „ Parameters (*1, *2, *3, *4, *5, *6) 
      −32  −31  −30 
    Hexadecimal 2Dh 33h  32h 2Dh 33h  31h 2Dh 33h  30h 
    Character  − 3 2  − 3 1  − 3 0 
     30 31 32 
    Hexadecimal 30h 33h 30h 30h 33h 31h 30h 33h 32h 
    Character 0 3 0 0 3 1 0 3 2 
     
    2.35.  Query Horizontal Position 
    Hexadecimal 02h 51h 48h 50h 03h
    Character  Q H P  
    „  Response (Callback) In the period when the command can be accepted 
    Hexadecimal 02h *1  *3  *5 03h 
    Character  *2 *4 *6  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes No  No  Yes Yes 
    „ Parameters (*1, *2, *3, *4, *5, *6) 
      −127   −126   −125  
    Hexadecimal  2Dh  31h  32h  37h  2Dh 31h  32h  36h  2Dh  31h  32h  35h 
    Character  −  1  2  7  −  1  2  6  −  1  2  5 
     125  126  127 
    Hexadecimal  31h  32h  35h  31h  32h  36h  31h  32h  37h 
    Character  1  2  5  1  2  6  1  2  7 
     
    2.36.  Query Vertical Position 
    Hexadecimal 02h 51h 56h 50h 03h
    Character  Q V P  
    „  Response (Callback) In the period when the command can be accepted 
    Hexadecimal 02h *1 *3 *5 03h 
    Character    *2 *4 *6   Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes No  No  Yes Yes 
    „ Parameters (*1, *2, *3, *4, *5, *6) 
      −64  −63  −62 
    Hexadecimal 2Dh 36h  34h 2Dh 36h  33h 2Dh 36h  32h 
    Character  − 6  4  − 6 3  − 6 2 
     62 63 64 
    Hexadecimal 36h  32h  36h  33h  36h  34h 
    Character 6  2  6  3  6  4 
      
    						
    							
    12/16 
      2.37. Query Clock Phase 
    Hexadecimal 02h 51h 43h 50h 03h
    Character  Q C P  
    „
     Response (Callback) In the period when the command can be accepted 
    Hexadecimal 02h *1  *3  *5 03h 
    Character  *2 *4 *6  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE 
    Yes No  No  Yes  Yes 
    „ Parameters (*1, *2, *3, *4, *5, *6) 
      −16  −15  −14 
    Hexadecimal 2Dh 31h  36h 2Dh 31h  36h 2Dh 31h  36h 
    Character  − 1 6  − 1 6  − 1 4 
     14 15 16 
    Hexadecimal 30h 31h 34h 30h 31h 35h 30h 31h 36h 
    Character 0 1 4 0 1 5 0 1 6 
    „  Note: • This command is acceptable only when  the input is COMPUTER 1, COMPUTER 2 or COMPONENT. In other cases, 
    ER401 is returned. 
     
    2.38.  Query Dot Clock 
    Hexadecimal 02h 51h 44h 43h 03h
    Character  Q D C  
    „ Response (Callback) In the period when the command can be accepted 
    Hexadecimal 02h *1  *3  *5 03h 
    Character  *2 *4 *6  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE 
    Yes No  No  Yes  Yes 
    „ Parameters (*1, *2, *3, *4, *5, *6) 
      −32  −31  −30 
    Hexadecimal 2Dh 33h  32h 2Dh 33h  31h 2Dh 33h  30h 
    Character  − 3 2  − 3 1  − 3 0 
     30 31 32 
    Hexadecimal 30h 33h 30h 30h 33h 31h 30h 33h 32h 
    Character 0 3 0 0 3 1 0 3 2 
    „  Note: • This command is acceptable only when the input is COMPUT ER 1 or COMPUTER. In other cases, ER401 is returned. 
     
    2.39.  Query Picture Mode 
    Hexadecimal 02h 51h 50h 4Dh 03h
    Character  Q P M  
    „  Response (Callback) In the period when the command can be accepted 
    Hexadecimal 02h *1  *3  *5 03h 
    Character  *2 *4 *6  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes No  Yes Yes Yes 
    „ Parameters (*1, *2, *3, *4, *5, *6) 
     DYNAMIC NATURAL STANDARD BLACKBOARD 
    Hexadecimal 44h 59h 4Eh 4Eh 41h 54h 53h 54h 44h 42h 42h 44h 
    Character D Y N N A  T  S T D B B D 
     
     
     
     
     
     
     
     
     
     
     
     
     
      
    						
    							
    13/16 
      2.40. Query Color Temperature 
    Hexadecimal 02h 51h 54h 45h 03h
    Character  Q T E  
    „
     Response (Callback) In the period when the command can be accepted 
    Hexadecimal  02h *1  *3 03h 
    Character  *2 *4  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes No  No  Yes Yes 
    „ Parameters (*1, *2, *3, *4) 
     LOW STANDARD HIGH 
    Hexadecimal 30h 31h 32h 
    Character 0 1 2 
     
    2.41. Query Keystone 
    Hexadecimal 02h 51h 4Bh 53h 03h
    Character  Q K S  
    „ Response (Callback) In the period when the command can be accepted 
    Hexadecimal 02h *1 *3 *5 *7 03h 
    Character    *2 *4 *6 *8   Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes No  Yes Yes Yes 
    „ Parameters (*1, *2,  *3, *4, *5, *6, *7, *8) 
     −32  −31  −30 
    Hexadecimal 2Dh 33h  32h 2Dh 33h  31h 2Dh 33h  30h 
    Character  − 3 2  − 3 1  − 3 0 
     30 31 32 
    Hexadecimal 30h 33h 30h 30h 33h 31h 30h 33h 32h 
    Character 0 3 0 0 3 1 0 3 2 
     
    2.42. Query SHUTTER 
    Hexadecimal 02h 51h 53h 48h 03h
    Character  Q S H  
    „  Response (Callback) OFF 
    Hexadecimal 02h 31h 03h 
    Character   0  ON Hexadecimal 02h 31h 03h 
    Character   1  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes No  Yes Yes Yes 
     
    2.43. Query FREEZE 
    Hexadecimal 02h 51h 46h 5Ah 03h
    Character  Q F Z  
    „ Response (Callback) OFF 
    Hexadecimal 02h 31h 03h 
    Character   0  ON Hexadecimal 02h 31h 03h 
    Character   1  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes No  Yes Yes Yes 
     
     
     
     
     
     
      
    						
    							
    14/16 
      2.44. Query Installation 
    Hexadecimal 02h 51h 53h 50h 03h
    Character  Q S P  
    „
     Response (Callback) FRONT-F 
    Hexadecimal 02h 30h 03h 
    Character  0  REAR-F  Hexadecimal 02h 31h 03h 
    Character   1  FRONT-C Hexadecimal 02h 32h 03h 
    Character   2  REAR-C Hexadecimal 02h 33h 03h 
    Character   3  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes Yes  Yes  Yes Yes 
     
    2.45.  Query Display Language 
    Hexadecimal 02h 51h 4Ch 47h 03h
    Character  Q L G  
    „ Response (Callback) In the period when the command can be accepted 
    Hexadecimal 02h *1  *3  *5 03h 
    Character  *2 *4 *6  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes Yes  Yes  Yes Yes 
    „ Parameters (*1, *2, *3, *4, *5, *6) 
     English  German  French 
    Hexadecimal 45h 4Eh 47h 44h 45h 55h 46h 52h 41h 
    Character E  N  G  D  E  U  F  R  A 
     Spanish  Italian  Japanese 
    Hexadecimal 45h 53h 50h 49h 54h 4Ch 4Ah 50h 4Eh 
    Character E  S  P  I  T  L  J  P  N 
     Chinese  Russian  Korean 
    Hexadecimal 43h 48h 49h 52h 55h 53h 4Bh 4Fh 52h 
    Character C H  I  R U S  K O R 
     Portuguese  Swedish  Norwegian 
    Hexadecimal 50h  4Fh  52h  53h  56h  45h  4Eh  4Fh  52h 
    Character P  O  R  S  V  E  N  O  R 
     Danish  Polish  Czech 
    Hexadecimal 44h 41h 4Eh 50h 4Fh 4Ch 43h 45h 53h 
    Character D  A  N  P  O  L  C  E  S 
     Hungarian  Thai 
    Hexadecimal 4Dh  41h  47h  54h  48h  41h 
    Character M  A  G  T  H  A 
     
    2.46. Query Lamp Runtime 
    Hexadecimal 02h 51h 24h 4Ch 03h
    Character  Q $ L  
    „ Response (Callback) In the period when the command can be accepted 
    Hexadecimal 02h *1 *3 *5 *7 03h 
    Character    *2 *4 *6 *8   Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes Yes  Yes  Yes Yes 
    „ Parameters (*1, *2,  *3, *4, *5, *6, *7, *8) 
      0 h  1 h 
    Hexadecimal 30h 30h 30h 30h 30h 30h 30h 31h 
    Character 0 0 0 0 0 0 0 1 
      9998 h  9999 h 
    Hexadecimal 39h 39h 39h 38h 39h 39h 39h 39h 
    Character 9 9 9 8 9 9 9 9 
    „ Note: • It returns with 0000 when the lamp runtime cannot be obtained.  
    						
    							
    15/16 
      2.47. Query Date 
    Hexadecimal 02h 51h 47h 44h 03h
    Character  Q G D  
    „
     Response (Callback) 
    Hexadecimal  02h *y1 *y2 *y3 *y4 *m1 *m2 *d1 *D2  *w  03h 
    Character             
    „ Parameters *y1—*y4: Year (4 digits) 
    *m1, *m2: Month (2 digits) 
    *d1, *d2: Day (2 digits) 
    *w: Day of the week (Mon = 1, Tue = 2, Wed  = 3, Thu = 4, Fri = 5, Sat = 6, Sun = 7) 
    Set it by UTC (Coordinated Universal Time). 
    Example: Saturday, April 21, 2007 
      *y1 *y2 *y3 *y4 *m1 *m2 *d1 *D2  *w 
    Hexadecimal  32h 30h 30h 37h 30h 34h 32h 31h 31h 
    Character  2 0 0 7 0 4 2 1 1 Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes Yes  Yes  Yes Yes 
     
    2.48. Query Time 
    Hexadecimal 02h 51h 47h 54h 03h
    Character  Q G T  
    „ Response (Callback) 
    Hexadecimal 02h *h1 *h2 *m1 *m2 *s1 *s2 03h 
    Character          
    „ Parameters *h1, *h2: Hour (2 digits) 
    *m1, *m2: Minute (2 digits) 
    *s1, *s2: Second (2 digits) 
    Set it by UTC (Coordinated Universal Time). 
    Example: 3 seconds at 3:45 p.m. 
     *h1 *h2 *m1 *m2 *s1 *s2 
    Hexadecimal  31h 35h 34h 35h 30h 33h 
    Character  1 5 4 5 0 3 Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
    Yes Yes  Yes  Yes Yes 
      
    2.49.  Query Filter Remaining Time 
    Hexadecimal 02h 51h  46h  49h 3Ah 35h  03h 
    Character   Q  F  I  :  5   
    „ Response(Callback) Example:1500hours 
    Hexadecimal 02h 31h 35h 30h 30h 03h
    Character    1 5 0 0   Acceptability  SECURITY STANDBY  NO SIGNAL  SHUTTER REMOTE
    Yes No  Yes  Yes Yes 
     
    2.50.  SIDE BY SIDE key (for FW100NT only) 
    Hexadecimal 02h  4Fh  44h   57h  03h 
    Character   O  D W   
    „ Response(Callback) In the period when the command can be accepted 
    Hexadecimal 02h  4Fh  44h  57h  03h 
    Character   O D W   Acceptability  SECURITY STANDBY  NO SIGNAL  SHUTTER REMOTE
    No No  Yes  No Yes 
    „ Notes: It is invalid during FREEZE, INDEX WINDOW, and DIGITAL ZOOM  
    						
    							16/16 
     
    2.51. Closed Caption (for FW100NTU/F100NTU/F100U only) 
    Hexadecimal 02h 4Fh 43h  43h 3Ah *1 03h 
    Character  O C C : *2  
     Parameters(*1, *2) 
     OFF CC1 CC2 CC3 CC4 
    Hexadecimal 30h 31h 32h 33h 34h 
    Character 0 1 2 3 4 
     Response(Callback) In the period when the command can be accepted 
    Hexadecimal 02h 4Fh 43h  43h 3A *1 03h 
    Character  O C C : *2  Acceptability 
    SECURITY STANDBY NO SIGNAL SHUTTER REMOTE 
    No No No No Yes 
     Notes: It is invalid during SIDE BY SIDE, FREEZE, INDEX WINDOW, and DIGITAL ZOOM.  
    2.52. Query Closed Caption (for FW100NTU/F100NTU/F100U only) 
    Hexadecimal 02h 51h 43h  43h 03h 
    Character  Q C C  
     Response(Callback) 
     OFF CC1 CC2 
    Hexadecimal 02h 30h 03h 02h 31h 03h 02h 32h 03h 
    Character  0   1   2  
     CC3 CC4 
    Hexadecimal 02h 33h 03h 02h 34h 03h 
    Character  3   4  Acceptability 
    SECURITY STANDBY NO SIGNAL SHUTTER REMOTE 
    Yes No No Yes Yes 
       
    						