Home > Panasonic > Projector > Panasonic LCD Projector PT-FW100NT PT-F100NT PT-F100 Operating Instructions

Panasonic LCD Projector PT-FW100NT PT-F100NT PT-F100 Operating Instructions

Here you can view all the pages of manual Panasonic LCD Projector PT-FW100NT PT-F100NT PT-F100 Operating Instructions. The Panasonic manuals for Projector are available online for free. You can easily download all the documents as PDF.

Page 1

Panasonic Projector RS-232C Control Specifications
PT-FW100NT/F100NT/F100 

Page 2

2/16 
 
Using the Serial Terminals 
 
1. Basic Format 
Transmission from the computer begins  with STX, then the command, parameter and ETX are sent in this order. 
Add parameters according to  the details of control. 
 
Basic control command (without parameter) 
Start  
(STX)  Command End 
(ETX) 
1 byte  3 bytes  1 byte 
 
Basic control command (with parameters) 
Start  
(STX)  Command Separator 
(colon)  Parameters End 
(ETX)
1 byte  3 bytes  1 byte  Undefined length  1 byte
 
Response (Callback) of...

Page 3

3/16 
 
2.  Basic Control Command 
Explanatory notes 
Yes: Enable 
No: Disable 
2.1.  Power ON (Lamp ON) 
Hexadecimal 02h 50h 4Fh 4Eh 03h 
Character  P O N  
„  Respone (Callback) In the period when the command can be accepted (Thi s command in power-on condition is included) 
Hexadecimal 02h 50h 4Fh 4Eh 03h 
Character  P O N  Acceptability  SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
Yes Yes  Yes  Yes (Yes) 
„  Note: • When you confirm whether to have succeeded in power- on, confirm it by QPW (Query...

Page 4

4/16 
  2.5. FREEZE key 
Hexadecimal 02h 4Fh 46h 5Ah 3Ah *1  03h 
Character    O F Z  : *2   
„
 Parameters (*1, *2) 
  Freeze OFF  Freeze ON 
Hexadecimal 30h  31h 
Character 0  1 
„ Response (Callback) In the period when the command can be accepted 
Hexadecimal 02h 4Fh 46h 5Ah 3Ah *1 03h 
Character  O F Z : *2  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
No No No No Yes 
 
2.6. Input Change 
Hexadecimal  02h 49h 49h 53h 3Ah *1  *3  *5  03h 
Character    I  I S : *2 *4 *6  
„ Parameters (*1,...

Page 5

5/16 
 
 
2.10. Down ( ) key 
Hexadecimal  02h 4Fh 43h 44h 03h 
Character  O C D  
„  Response (Callback) In the period when the command can be accepted 
Hexadecimal  02h 4Fh 43h 44h 03h 
Character  O C D  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
Yes No  Yes  No Yes 
 
2.11. Left ( I) key 
Hexadecimal 02h 4Fh 43h 4Ch 03h 
Character  O C L  
„ Response (Callback) In the period when the command can be accepted 
Hexadecimal 02h 4Fh 43h 4Ch 03h 
Character  O C L  Acceptability SECURITY...

Page 6

6/16 
  2.16.  INDEX WINDOW key 
Hexadecimal  02h 4Fh 49h 58h 03h 
Character  O I X  
„
 Response (Callback) In the period when the command can be accepted 
Hexadecimal  02h 4Fh 49h 58h 03h 
Character  O I X  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
No No No No Yes 
„ Notes: • It is invalid during SIDE BY SIDE with the PT-FW100NT. 
 
2.17.  DIGITAL ZOOM + key 
Hexadecimal  02h 44h 5Ah 55h 03h 
Character    D Z U   
„ Response (Callback) In the period when the command can be accepted...

Page 7

7/16 
  2.20.  Audio Volume Level 
Hexadecimal 02h 41h 56h 4Ch 3Ah *1 *3 *5 03h 
Character    A V L  : *2 *4 *6   
„
 Parameters (*1, *2, *3, *4, *5, *6) 
 0 1 2 
Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h 
Character 0 0 0 0 0 1 0 0 2 
 61  62  63 
Hexadecimal 30h 36h 31h 30h 36h 32h 30h 36h 33h 
Character 0 6 1 0 6 2 0 6 3 
„ Response (Callback) In the period when the command can be accepted 
Hexadecimal 02h 41h 56h 4Ch 3Ah *1  *3  *5 03h 
Character    A V L  : *2 *4 *6   Acceptability SECURITY...

Page 8

8/16 
  2.23. Query Power 
Hexadecimal 02h 51h 50h 57h 03h
Character  Q P W  
„
 Response (Callback) OFF 
Hexadecimal  02h 30h 30h 31h 03h 
Character  0 0 0  ON Hexadecimal  02h 30h 30h 31h 03h 
Character  0 0 1  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
Yes Yes  Yes  Yes Yes 
 
2.24. Query Lamp Status 
Hexadecimal 02h 51h 24h 53h 03h
Character  Q $ S  
„ Response (Callback) Lamp OFF 
Hexadecimal 02h 30h 03h 
Character  0  In turning ON  Hexadecimal 02h 31h 03h 
Character   1  Lamp ON...

Page 9

9/16 
  2.26.  Query Audio Volume Level 
Hexadecimal 02h 51h 41h 56h 03h
Character  Q A V  In the period when the command can be accepted 
Hexadecimal 02h *1  *3  *5 03h 
Character  *2 *4 *6  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
Yes No  Yes Yes Yes 
„ Parameters (*1, *2, *3, *4, *5, *6) 
 0 1 2 
Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h 
Character 0 0 0 0 0 1 0 0 2 
 61  62  63 
Hexadecimal 30h 36h 31h 30h 36h 32h 30h 36h 33h 
Character 0 6 1 0 6 2 0 6 3 
 
2.27. Query Color...

Page 10

10/16 
  2.30. Query Contrast 
Hexadecimal 02h 51h 56h 52h 03h
Character  Q V R  
„
 Response (Callback) In the period when the command can be accepted 
Hexadecimal 02h *1  *3  *5 03h 
Character  *2 *4 *6  Acceptability SECURITY STANDBY NO SIGNAL SHUTTER REMOTE
Yes No  No  Yes Yes 
„ Parameters (*1, *2, *3, *4, *5, *6) 
  −32  −31  −30 
Hexadecimal 2Dh 33h  32h 2Dh 33h  31h 2Dh 33h  30h 
Character  − 3 2  − 3 1  − 3 0 
 30 31 32 
Hexadecimal 30h 33h 30h 30h 33h 31h 30h 33h 32h 
Character 0 3 0 0 3 1 0 3...
Start reading Panasonic LCD Projector PT-FW100NT PT-F100NT PT-F100 Operating Instructions

Related Manuals for Panasonic LCD Projector PT-FW100NT PT-F100NT PT-F100 Operating Instructions

All Panasonic manuals