2.1 PT Programming PT Programming Manual 31 [625] Destination for Overflow Time Expiration [626] Overflow Time [627] Destination When All Busy [628] Queuing Call Capacity [629] Queuing Hurry-up Level 1 Day/2 Lunch/ 3 Break/4 NightMax. 32 digits Destination No.Time No.[625] STORE STOREEND 001–128 Incoming Call Distribution Group No. Overflow Time[626] STORESTOREEND( None/1–125)×10 s 001–128 Incoming Call Distribution Group No. Max. 32 digits Destination No. 1 Day/2 Lunch/ 3 Break/4 Night Time No.[627] STORE STOREEND 001–128 Incoming Call Distribution Group No. 0–30 Number in Queuing 30 [628] STORESTOREEND 001–128 Incoming Call Distribution Group No. None/1–30 Hurry-up Level[629] STORESTOREEND 001–128 Incoming Call Distribution Group No.
2.1 PT Programming 32 PT Programming Manual [630] Queuing Time Table [631] Sequences in Queuing Time Table [632] Maximum Number of Agents [640] Extension User Groups of a Paging Group 1 Day/2 Lunch/ 3 Break/4 NightNone/01–64 Table No.Time No.[630] STORE STOREEND 001–128 Incoming Call Distribution Group No. [631] 01–16 * A number must be entered in place of the N. Location No. 01–64 Table No. None/Overflow/ Disconnect/N × 5 s/ Sequence N/OGM NSTORE STOREEND SELECT No Limitation/1–32 Number of Agents[632] STORESTOREEND 001–128 Incoming Call Distribution Group No. [640] 001–032 Extn. User Group No. 01–32 Paging Group No. No/YesPaging Group No. 01–31=Extn. User Group No. 001–031, Paging Group No. 32=All extension user groups STORE STOREENDSELECT
2.1 PT Programming PT Programming Manual 33 [641] External Pager of a Paging Group [650] Extension User Groups of a Pickup Group [660] VM Group Floating Extension Number [680] Idle Extension Hunting Type [681] Idle Extension Hunting Group Member [641] 1 External Pager No. 01–32 Paging Group No. No/ YesSTORE STOREEND SELECT [650] 01–64 Pickup Group No. No/YesPickup Group No. 01–32=Extn. User Group No. 001–032, Pickup Group No. 33–64=All extension user groups STORE STOREENDSELECT 001–032 Extn. User Group No. [660] 1 VM (DPT) Group No. 1–5 digits Extn. No. STORESTOREEND500 [680] 01–64 Hunting Group No. Circular/ TerminateSTORESTOREENDSELECT [681] 01–16 Location No. 01–64 Hunting Group No. 1–5 digits Extn. No. STORE STOREEND
2.1 PT Programming 34 PT Programming Manual [690] PS Registration Note Please refer to section 2.7.7 Connecting a Cell Station to the PBX in the Installation Manual for details about Portable Station (PS) registration. [691] PS Termination [692] Personal Identification Number (PIN) for PS Registration [699] CS Status Reference 2.1.10 Resource/Interface Programming [700] External Pager Floating Extension Number [690] 001–028 PS No. KX-TD7690 1–4 digits To the PS operation belowExtn. No. Push power button for 2 seconds.Push F3 key for 2 seconds.C.Tone STORESTOREEND [691] 001–028 PS No. STORESTOREEND [692] 1–4 digits PIN for PS Registration 1234STORESTOREEND [699] 01–06 Slot No. Reference only CS Status 01–08 Port No. STOREEND [700] 1 Pager No. 1–5 digits Extn. No. STORESTOREEND600
2.1 PT Programming PT Programming Manual 35 [710] Audio Source Selection for BGM [711] Music on Hold [712] Music for Transfer [720] Doorphone Call Destination [729] Doorphone Number Reference [730] Outgoing Message (OGM) Floating Extension Number [710] External/ Internal1/ Internal2 STORESTOREENDSELECT [711] Beep/BGM BGM Audio Source STORESTOREEND [712] Hold Music/ Ring backSTORESTOREENDSELECT [720] 1 Day/2 Lunch/ 3 Break/4 Night08–09 Max. 32 digits Slot No. 1–4 Port No.Time No. Destination No. STORE STOREEND [729] 08–09 Slot No. Reference only Doorphone No. 1–4 Port No. STOREEND [730] 01–32 Message No. 1–5 digits Extn. No. STORESTOREEND501–532
2.1 PT Programming 36 PT Programming Manual [731] Outgoing Message (OGM) Name [732] DISA Security Mode 2.1.11 SMDR & Maintenance Programming [800] RS-232C Parameter—New Line Code [800] RS-232C Parameter—Baud Rate [800] RS-232C Parameter—Word Length [800] RS-232C Parameter—Parity Bit [731] 01–32 Message No. Max. 20 characters Name STORESTOREEND [732] None/ CO Line/AllSTORESTOREENDSELECT [800] CR+LF/CR1 Location STORESTOREENDSELECT [800] 2400/4800/9600/ 19200/38400/57600/ 115200 bps2 Location STORESTOREENDSELECT [800] 7/ 8 bits 3 Location STORESTOREENDSELECT [800] None/Mark/ Space/Even/Odd 4 Location STORESTOREENDSELECT
2.1 PT Programming PT Programming Manual 37 [800] RS-232C Parameter—Stop Bit Length [801] External Modem Control [802] SMDR Page Length [803] SMDR Skip Perforation [804] SMDR Outgoing Call Printing [805] SMDR Incoming Call Printing [800] 1 bit/2 bits 5 Location STORESTOREENDSELECT [801]Command No. 1–5STORESTOREEND [802] 4–99 lines 66 Page length STORESTOREEND [803] 0–95 lines Skip Perforation 0STORESTOREEND [804] No print/ PrintSTORESTOREENDSELECT [805] No print/ PrintSTORESTOREENDSELECT
2.1 PT Programming 38 PT Programming Manual [810] Remote Programming [811] Modem Floating Extension Number 2.1.12 Card Programming [900] Slot Card Type Reference [901] Slot Card Deletion [902] Slot Card Reset Disable/ Enable [810] STORESTOREENDSELECT [811] 1–5 digits Extn. No. 599STORESTOREEND [900] 01–11 Reference only Slot No.Card Name STOREEND [901] 01–11 Slot No.Delete To the Next Slot No. NEXT Confirming the deleting operation. STORESTOREEND [902] 01–11 Slot No.Reset Confirming the resetting operation.STORESTOREEND
3.1 Revision History 40 PT Programming Manual 3.1 Revision History 3.1.1 KX-TAW848 PSMPR Software File Version 4.0xxx Changed Contents [003] Extension Number [004] Extension Name [005] Extension Personal Identification Number (PIN) [006] Operator Assignment [007] DSS Console Paired Telephone [450] DIL 1:1 Destination [602] Class of Service [603] Extension User Group [604] Extension Intercept Destination [605] Call Forwarding—No Answer Time [620] Incoming Call Distribution Group Member [622] Incoming Call Distribution Group Floating Extension Number [660] VM Group Floating Extension Number [681] Idle Extension Hunting Group Member [700] External Pager Floating Extension Number [730] Outgoing Message (OGM) Floating Extension Number [811] Modem Floating Extension Number